Citation
Saeed, Diyar, et al. "Initial Acute in Vivo Performance of the Cleveland Clinic PediPump Left Ventricular Assist Device." ASAIO Journal (American Society for Artificial Internal Organs : 1992), vol. 53, no. 6, 2007, pp. 766-70.
Saeed D, Weber S, Ootaki Y, et al. Initial acute in vivo performance of the Cleveland Clinic PediPump left ventricular assist device. ASAIO J. 2007;53(6):766-70.
Saeed, D., Weber, S., Ootaki, Y., Mielke, N., Ootaki, C., Akiyama, M., Horai, T., Catanese, J., Fumoto, H., Hideyuki, F., Dessoffy, R., Dudzinski, D. T., Gu, L., Casas, F., Smith, W. A., Fukamachi, K., & Duncan, B. W. (2007). Initial acute in vivo performance of the Cleveland Clinic PediPump left ventricular assist device. ASAIO Journal (American Society for Artificial Internal Organs : 1992), 53(6), 766-70.
Saeed D, et al. Initial Acute in Vivo Performance of the Cleveland Clinic PediPump Left Ventricular Assist Device. ASAIO J. 2007 Nov-Dec;53(6):766-70. PubMed PMID: 18043163.
TY - JOUR
T1 - Initial acute in vivo performance of the Cleveland Clinic PediPump left ventricular assist device.
AU - Saeed,Diyar,
AU - Weber,Stephan,
AU - Ootaki,Yoshio,
AU - Mielke,Nicole,
AU - Ootaki,Chiyo,
AU - Akiyama,Masatoshi,
AU - Horai,Tetsuya,
AU - Catanese,Jacquelyn,
AU - Fumoto,Hideyuki,
AU - Hideyuki,Fumoto,
AU - Dessoffy,Raymond,
AU - Dudzinski,David T,
AU - Gu,Lei,
AU - Casas,Fernando,
AU - Smith,William A,
AU - Fukamachi,Kiyotaka,
AU - Duncan,Brian W,
PY - 2007/11/29/pubmed
PY - 2008/1/8/medline
PY - 2007/11/29/entrez
SP - 766
EP - 70
JF - ASAIO journal (American Society for Artificial Internal Organs : 1992)
JO - ASAIO J
VL - 53
IS - 6
N2 - The PediPump is a small ventricular assist device (VAD) with a hydraulic output range designed to support children from newborns to adolescents. The present report describes our initial evaluation of the PediPump as a left VAD in an acute sheep model. The PediPump was implanted in two sheep (50.8 and 62.7 kg). Pump speed was adjusted to achieve a flow of 2 L/min with the naturally occurring preload and afterload conditions to evaluate pump performance under a steady hemodynamic state for 4 hours. Upon completion, pump performance was evaluated under various blood pressure and heart rate conditions. During steady-state evaluations, the ascending aortic flow and pump speed varied slightly depending on systemic arterial pressure variations. During the hemodynamic manipulation studies, flows ranged between 0.5 and 3.2 L/min with pump speeds of 5,200-16,200 rpm and motor current of 0.06-0.75 A. The PediPump demonstrated good initial hemodynamic performance for use as an implantable left VAD. However, some depositions were detected at the time of explanation, mainly at the rear of the pump. We are continuing with further acute studies to evaluate pump performance in anticipation of beginning chronic studies to evaluate long-term biocompatibility.
SN - 1538-943X
UR - https://www.unboundmedicine.com/medline/citation/18043163/Initial_acute_in_vivo_performance_of_the_Cleveland_Clinic_PediPump_left_ventricular_assist_device_
DB - PRIME
DP - Unbound Medicine
ER -