Tags

Type your tag names separated by a space and hit enter

Preliminary application of one-level posterior lumbar interbody fusion with prospace and facet fusion using local autograft.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2007 Nov; 21(11):1155-9.ZX

Abstract

OBJECTIVE

To evaluate the safety and efficacy of one-level posterior lumbar interbody fusion (PLIF) combined with Prospace and facet fusion using local autograft.

METHODS

Clinical and radiographic data of 76 patients treated by this technique was reviewed from May 2002 to December 2004. Of them, there were 52 males and 24 females, with an average age of 53.2 years (23-81 years), including 60 cases of degenerative disc disease, 9 cases of failed back surgery syndrome and 3 cases of spondylolysis.The disese courses were 1.2-8.7 years (mean 3.6 years). The levels of PLIF were: L2,3 in 2 cases, L3,4 in 7, L4,5 in 54, L5/S1 in 10, L4/ S1 in 1 and L5,6 in 2. After decompression, Prospace was inserted into interbody space bilaterally, and located in disc space 4 mm beyond the rear edge of the vertebral body. Local laminectomy autograft was packed both laterally into and between 2 implants. Then the remanent local autograft was placed over facet bed. Pedicle screws were used after insertion of Prospace. Clinical results were evaluated by the JOA score. Disc height ratio and lumbar lordosis angles were measured on lateral radiographs. Fusion status was determined by evidence of bridge trabeculae across facet joint and interbody space on CT scan without mobility in lateral dynamic X-rays, and no radiolucent gap between Prospace and endplate. Paired t-test was used for statistical analysis.

RESULTS

Mean blood loss and operative time was 384 ml and 178 minutes, respectively. The average JOA score at final follow-up (26.1 +/- 2.7) was significantly improved when compared with that of pre-operation (14.5 +/- 4.0, P < 0.05), with a mean recovery rate of JOA score 81.1% (37.5%-100.0%). The fusion rate was 97.4% (74/76). Mean disc height ratio and the involved segmental lordosis angle were increased from preoperative 0.27 +/- 0.07 and 5.8 +/- 2.2 degrees to 0.33 +/- 0.06 and 11.3 +/- 2.0 degrees respectively at the final follow-up, and the differences were significant (P < 0.05). There were no device-related complications.

CONCLUSION

This surgical technique combined with Prospace interbody device is a safe and effective surgical option for patients with one-level lumbar disorders when PLIF is warranted.

Authors+Show Affiliations

Department of Spine Surgery, The First Affiliated Hospital of Sun-Yat-Sen University, Guangzhou Guangdong, 510700, PR China. houqinglong@163.comNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article

Language

eng

PubMed ID

18069464

Citation

Long, Houqing, et al. "Preliminary Application of One-level Posterior Lumbar Interbody Fusion With Prospace and Facet Fusion Using Local Autograft." Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi = Zhongguo Xiufu Chongjian Waike Zazhi = Chinese Journal of Reparative and Reconstructive Surgery, vol. 21, no. 11, 2007, pp. 1155-9.
Long H, Kazunasa U, Liu S, et al. Preliminary application of one-level posterior lumbar interbody fusion with prospace and facet fusion using local autograft. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2007;21(11):1155-9.
Long, H., Kazunasa, U., Liu, S., Akio, S., & Taito, I. (2007). Preliminary application of one-level posterior lumbar interbody fusion with prospace and facet fusion using local autograft. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi = Zhongguo Xiufu Chongjian Waike Zazhi = Chinese Journal of Reparative and Reconstructive Surgery, 21(11), 1155-9.
Long H, et al. Preliminary Application of One-level Posterior Lumbar Interbody Fusion With Prospace and Facet Fusion Using Local Autograft. Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi. 2007;21(11):1155-9. PubMed PMID: 18069464.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Preliminary application of one-level posterior lumbar interbody fusion with prospace and facet fusion using local autograft. AU - Long,Houqing, AU - Kazunasa,Ueyama, AU - Liu,Shaoyu, AU - Akio,Sannohe, AU - Taito,Itabashi, PY - 2007/12/12/pubmed PY - 2009/8/8/medline PY - 2007/12/12/entrez SP - 1155 EP - 9 JF - Zhongguo xiu fu chong jian wai ke za zhi = Zhongguo xiufu chongjian waike zazhi = Chinese journal of reparative and reconstructive surgery JO - Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi VL - 21 IS - 11 N2 - OBJECTIVE: To evaluate the safety and efficacy of one-level posterior lumbar interbody fusion (PLIF) combined with Prospace and facet fusion using local autograft. METHODS: Clinical and radiographic data of 76 patients treated by this technique was reviewed from May 2002 to December 2004. Of them, there were 52 males and 24 females, with an average age of 53.2 years (23-81 years), including 60 cases of degenerative disc disease, 9 cases of failed back surgery syndrome and 3 cases of spondylolysis.The disese courses were 1.2-8.7 years (mean 3.6 years). The levels of PLIF were: L2,3 in 2 cases, L3,4 in 7, L4,5 in 54, L5/S1 in 10, L4/ S1 in 1 and L5,6 in 2. After decompression, Prospace was inserted into interbody space bilaterally, and located in disc space 4 mm beyond the rear edge of the vertebral body. Local laminectomy autograft was packed both laterally into and between 2 implants. Then the remanent local autograft was placed over facet bed. Pedicle screws were used after insertion of Prospace. Clinical results were evaluated by the JOA score. Disc height ratio and lumbar lordosis angles were measured on lateral radiographs. Fusion status was determined by evidence of bridge trabeculae across facet joint and interbody space on CT scan without mobility in lateral dynamic X-rays, and no radiolucent gap between Prospace and endplate. Paired t-test was used for statistical analysis. RESULTS: Mean blood loss and operative time was 384 ml and 178 minutes, respectively. The average JOA score at final follow-up (26.1 +/- 2.7) was significantly improved when compared with that of pre-operation (14.5 +/- 4.0, P < 0.05), with a mean recovery rate of JOA score 81.1% (37.5%-100.0%). The fusion rate was 97.4% (74/76). Mean disc height ratio and the involved segmental lordosis angle were increased from preoperative 0.27 +/- 0.07 and 5.8 +/- 2.2 degrees to 0.33 +/- 0.06 and 11.3 +/- 2.0 degrees respectively at the final follow-up, and the differences were significant (P < 0.05). There were no device-related complications. CONCLUSION: This surgical technique combined with Prospace interbody device is a safe and effective surgical option for patients with one-level lumbar disorders when PLIF is warranted. SN - 1002-1892 UR - https://www.unboundmedicine.com/medline/citation/18069464/Preliminary_application_of_one_level_posterior_lumbar_interbody_fusion_with_prospace_and_facet_fusion_using_local_autograft_ DB - PRIME DP - Unbound Medicine ER -