Tags

Type your tag names separated by a space and hit enter

Dissolution test for site-specific release isoniazid pellets in USP apparatus 3 (reciprocating cylinder): optimization using response surface methodology.
Eur J Pharm Biopharm. 2008 Jun; 69(2):769-75.EJ

Abstract

The present work aims to predict drug release from novel site-specific release isoniazid pellets, in USP dissolution test apparatus 3, using the response surface methodology (RSM). Site-specific release isoniazid pellets were prepared by extrusion-spheronization followed by aqueous coating of Acryl-EZE. RSM was employed for designing of the experiment, generation of mathematical models and optimization study. A 3(2) full factorial design was used to study the effect of two factors (at three levels), namely volume of dissolution medium (150, 200, 250 ml) and reciprocation rate (5, 15, 25 dips per min). Amount of drug released in 0.1N hydrochloric acid at 2h and in pH 6.8 phosphate buffer at 45 min were selected as responses. Results revealed that both, the volume of medium and reciprocation rate, are significant factors affecting isoniazid release. A second order polynomial equation fitted to the data was used to predict the responses in the optimal region. The optimized conditions resulted in dissolution data that were close to the predicted values. The proposed mathematical model is found to be robust and accurate for optimization of dissolution test conditions for site-specific release isoniazid pellets.

Authors+Show Affiliations

B V Patel PERD Centre, Department of Pharmaceutics, Ahmedabad, India.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

18191554

Citation

Joshi, Amita, et al. "Dissolution Test for Site-specific Release Isoniazid Pellets in USP Apparatus 3 (reciprocating Cylinder): Optimization Using Response Surface Methodology." European Journal of Pharmaceutics and Biopharmaceutics : Official Journal of Arbeitsgemeinschaft Fur Pharmazeutische Verfahrenstechnik E.V, vol. 69, no. 2, 2008, pp. 769-75.
Joshi A, Pund S, Nivsarkar M, et al. Dissolution test for site-specific release isoniazid pellets in USP apparatus 3 (reciprocating cylinder): optimization using response surface methodology. Eur J Pharm Biopharm. 2008;69(2):769-75.
Joshi, A., Pund, S., Nivsarkar, M., Vasu, K., & Shishoo, C. (2008). Dissolution test for site-specific release isoniazid pellets in USP apparatus 3 (reciprocating cylinder): optimization using response surface methodology. European Journal of Pharmaceutics and Biopharmaceutics : Official Journal of Arbeitsgemeinschaft Fur Pharmazeutische Verfahrenstechnik E.V, 69(2), 769-75. https://doi.org/10.1016/j.ejpb.2007.11.020
Joshi A, et al. Dissolution Test for Site-specific Release Isoniazid Pellets in USP Apparatus 3 (reciprocating Cylinder): Optimization Using Response Surface Methodology. Eur J Pharm Biopharm. 2008;69(2):769-75. PubMed PMID: 18191554.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Dissolution test for site-specific release isoniazid pellets in USP apparatus 3 (reciprocating cylinder): optimization using response surface methodology. AU - Joshi,Amita, AU - Pund,Swati, AU - Nivsarkar,Manish, AU - Vasu,Kamala, AU - Shishoo,Chamanlal, Y1 - 2007/12/14/ PY - 2007/09/11/received PY - 2007/11/30/revised PY - 2007/11/30/accepted PY - 2008/1/15/pubmed PY - 2008/8/30/medline PY - 2008/1/15/entrez SP - 769 EP - 75 JF - European journal of pharmaceutics and biopharmaceutics : official journal of Arbeitsgemeinschaft fur Pharmazeutische Verfahrenstechnik e.V JO - Eur J Pharm Biopharm VL - 69 IS - 2 N2 - The present work aims to predict drug release from novel site-specific release isoniazid pellets, in USP dissolution test apparatus 3, using the response surface methodology (RSM). Site-specific release isoniazid pellets were prepared by extrusion-spheronization followed by aqueous coating of Acryl-EZE. RSM was employed for designing of the experiment, generation of mathematical models and optimization study. A 3(2) full factorial design was used to study the effect of two factors (at three levels), namely volume of dissolution medium (150, 200, 250 ml) and reciprocation rate (5, 15, 25 dips per min). Amount of drug released in 0.1N hydrochloric acid at 2h and in pH 6.8 phosphate buffer at 45 min were selected as responses. Results revealed that both, the volume of medium and reciprocation rate, are significant factors affecting isoniazid release. A second order polynomial equation fitted to the data was used to predict the responses in the optimal region. The optimized conditions resulted in dissolution data that were close to the predicted values. The proposed mathematical model is found to be robust and accurate for optimization of dissolution test conditions for site-specific release isoniazid pellets. SN - 0939-6411 UR - https://www.unboundmedicine.com/medline/citation/18191554/Dissolution_test_for_site_specific_release_isoniazid_pellets_in_USP_apparatus_3__reciprocating_cylinder_:_optimization_using_response_surface_methodology_ DB - PRIME DP - Unbound Medicine ER -