[Isolated tubal torsion as a late complication of laparoscopic sterilization].

Abstract

A patient who had been sterilised laparoscopically four years previously was admitted with torsion of the left salpinx from the site of electrocoagulation and outwards. Tubal torsion is thus a possible late complication of laparoscopic sterilisation.

Authors+Show Affiliations

,

Gynaekologisk afsnit, kirurgisk afdeling, Skive Sygehus.

Source

Ugeskrift for laeger 153:27 1991 Jul 1 pg 1946-7