Tags

Type your tag names separated by a space and hit enter

Voltammetric determination of aminobiphenyls at a boron-doped nanocrystalline diamond film electrode.
Talanta. 2007 Dec 15; 74(3):421-6.T

Abstract

Voltammetric behavior of 2-aminobiphenyl, 3-aminobiphenyl, and 4-aminobiphenyl at a boron-doped nanocrystalline diamond film electrode was investigated using cyclic voltammetry and differential pulse voltammetry. Optimum conditions have been found for the determination of those genotoxic substances by differential pulse voltammetry at the above given electrode in the concentration range of 2 x 10(-7) to 1 x 10(-5) mol/L.

Authors+Show Affiliations

Charles University in Prague, Faculty of Science, Department of Analytical Chemistry, UNESCO Laboratory of Environmental Electrochemistry, 12843 Prague 2, Czech Republic. Barek@natur.cuni.czNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

18371658

Citation

Barek, Jiri, et al. "Voltammetric Determination of Aminobiphenyls at a Boron-doped Nanocrystalline Diamond Film Electrode." Talanta, vol. 74, no. 3, 2007, pp. 421-6.
Barek J, Jandová K, Pecková K, et al. Voltammetric determination of aminobiphenyls at a boron-doped nanocrystalline diamond film electrode. Talanta. 2007;74(3):421-6.
Barek, J., Jandová, K., Pecková, K., & Zima, J. (2007). Voltammetric determination of aminobiphenyls at a boron-doped nanocrystalline diamond film electrode. Talanta, 74(3), 421-6. https://doi.org/10.1016/j.talanta.2007.08.039
Barek J, et al. Voltammetric Determination of Aminobiphenyls at a Boron-doped Nanocrystalline Diamond Film Electrode. Talanta. 2007 Dec 15;74(3):421-6. PubMed PMID: 18371658.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Voltammetric determination of aminobiphenyls at a boron-doped nanocrystalline diamond film electrode. AU - Barek,Jiri, AU - Jandová,Katerina, AU - Pecková,Karolina, AU - Zima,Jirí, Y1 - 2007/09/08/ PY - 2007/07/19/received PY - 2007/08/29/revised PY - 2007/08/31/accepted PY - 2008/3/29/pubmed PY - 2008/7/12/medline PY - 2008/3/29/entrez SP - 421 EP - 6 JF - Talanta JO - Talanta VL - 74 IS - 3 N2 - Voltammetric behavior of 2-aminobiphenyl, 3-aminobiphenyl, and 4-aminobiphenyl at a boron-doped nanocrystalline diamond film electrode was investigated using cyclic voltammetry and differential pulse voltammetry. Optimum conditions have been found for the determination of those genotoxic substances by differential pulse voltammetry at the above given electrode in the concentration range of 2 x 10(-7) to 1 x 10(-5) mol/L. SN - 1873-3573 UR - https://www.unboundmedicine.com/medline/citation/18371658/Voltammetric_determination_of_aminobiphenyls_at_a_boron_doped_nanocrystalline_diamond_film_electrode_ L2 - https://linkinghub.elsevier.com/retrieve/pii/S0039-9140(07)00615-7 DB - PRIME DP - Unbound Medicine ER -