Tags

Type your tag names separated by a space and hit enter

Evaluation of different nucleic acid amplification techniques for the detection of M. pneumoniae, C. pneumoniae and Legionella spp. in respiratory specimens from patients with community-acquired pneumonia.
J Microbiol Methods. 2008 Jun; 73(3):257-62.JM

Abstract

The number of pathogens involved in community-acquired pneumonia, with varying susceptibilities to antimicrobials, is numerous constituting an enormous challenge for diagnostic microbiology. Differentiation of infections due to Streptococcus pneumoniae and those due to Mycoplasma pneumoniae, Chlamydophila pneumoniae, or L. pneumophila as well as those due to viruses is essential to allow correct decisions concerning the antibiotics to be administered. The sensitivity and specificity of real-time simplex and multiplex nucleic acid sequence-based amplification (NASBA), and simplex PCR were compared for the detection of M. pneumoniae, C. pneumoniae and Legionella spp. in respiratory specimens from hospitalized and outpatients with community-acquired pneumonia (CAP). Two hundred fifty one respiratory specimens were collected from 147 patients with CAP. NASBA was done using the NucliSens Basic Kit (bioMérieux). PCR for M. pneumoniae and C. pneumoniae was done as described earlier [Ieven, M., Ursi, D., Van Bever, H., Quint, W., Niesters, H. G. M., and Goossens, H. 1996. Detection of Mycoplasma pneumoniae by two polymerase chain reactions and role of M. pneumoniae in acute respiratory tract infections in pediatric patients. J. Infect. Dis. 173, 1445-14452.; Ursi, D., Ieven, M., Van Bever, H. P., and Goossens, H. 1998. Construction of an internal control for the detection of Chlamydia pneumoniae by PCR. Mol. Cellul. Probes. 12, 235-238.]. A real-time PCR was developed to detect L. pneumophila whereas a real-time NASBA was designed to detect Legionella spp. All samples with discordant results were re-analysed. Compared to an expanded gold standard the sensitivities of the different techniques, were 77.8%, 100%, and 100% for detection of M. pneumoniae; and 50%, 100%, and 50% for detection of L. pneumophila by PCR, real-time simplex NASBA, and real-time multiplex NASBA, respectively. C. pneumoniae was detected in two samples only. Simplex real-time NASBA proved to be more sensitive than simplex PCR and was also more sensitive than real-time multiplex NASBA, as previously found with spiked clinical specimens. It's practical attractiveness pleads for further optimalisation of the multiplex approach.

Authors+Show Affiliations

Department of Microbiology, Vaccine and Infectious Disease Institute, University of Antwerp UIA, Antwerp, Belgium. Katherine.loens@ua.ac.beNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Comparative Study
Evaluation Study
Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

18378345

Citation

Loens, K, et al. "Evaluation of Different Nucleic Acid Amplification Techniques for the Detection of M. Pneumoniae, C. Pneumoniae and Legionella Spp. in Respiratory Specimens From Patients With Community-acquired Pneumonia." Journal of Microbiological Methods, vol. 73, no. 3, 2008, pp. 257-62.
Loens K, Beck T, Ursi D, et al. Evaluation of different nucleic acid amplification techniques for the detection of M. pneumoniae, C. pneumoniae and Legionella spp. in respiratory specimens from patients with community-acquired pneumonia. J Microbiol Methods. 2008;73(3):257-62.
Loens, K., Beck, T., Ursi, D., Overdijk, M., Sillekens, P., Goossens, H., & Ieven, M. (2008). Evaluation of different nucleic acid amplification techniques for the detection of M. pneumoniae, C. pneumoniae and Legionella spp. in respiratory specimens from patients with community-acquired pneumonia. Journal of Microbiological Methods, 73(3), 257-62. https://doi.org/10.1016/j.mimet.2008.02.010
Loens K, et al. Evaluation of Different Nucleic Acid Amplification Techniques for the Detection of M. Pneumoniae, C. Pneumoniae and Legionella Spp. in Respiratory Specimens From Patients With Community-acquired Pneumonia. J Microbiol Methods. 2008;73(3):257-62. PubMed PMID: 18378345.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Evaluation of different nucleic acid amplification techniques for the detection of M. pneumoniae, C. pneumoniae and Legionella spp. in respiratory specimens from patients with community-acquired pneumonia. AU - Loens,K, AU - Beck,T, AU - Ursi,D, AU - Overdijk,M, AU - Sillekens,P, AU - Goossens,H, AU - Ieven,M, Y1 - 2008/03/10/ PY - 2007/07/25/received PY - 2008/01/21/revised PY - 2008/02/15/accepted PY - 2008/4/2/pubmed PY - 2008/7/4/medline PY - 2008/4/2/entrez SP - 257 EP - 62 JF - Journal of microbiological methods JO - J Microbiol Methods VL - 73 IS - 3 N2 - The number of pathogens involved in community-acquired pneumonia, with varying susceptibilities to antimicrobials, is numerous constituting an enormous challenge for diagnostic microbiology. Differentiation of infections due to Streptococcus pneumoniae and those due to Mycoplasma pneumoniae, Chlamydophila pneumoniae, or L. pneumophila as well as those due to viruses is essential to allow correct decisions concerning the antibiotics to be administered. The sensitivity and specificity of real-time simplex and multiplex nucleic acid sequence-based amplification (NASBA), and simplex PCR were compared for the detection of M. pneumoniae, C. pneumoniae and Legionella spp. in respiratory specimens from hospitalized and outpatients with community-acquired pneumonia (CAP). Two hundred fifty one respiratory specimens were collected from 147 patients with CAP. NASBA was done using the NucliSens Basic Kit (bioMérieux). PCR for M. pneumoniae and C. pneumoniae was done as described earlier [Ieven, M., Ursi, D., Van Bever, H., Quint, W., Niesters, H. G. M., and Goossens, H. 1996. Detection of Mycoplasma pneumoniae by two polymerase chain reactions and role of M. pneumoniae in acute respiratory tract infections in pediatric patients. J. Infect. Dis. 173, 1445-14452.; Ursi, D., Ieven, M., Van Bever, H. P., and Goossens, H. 1998. Construction of an internal control for the detection of Chlamydia pneumoniae by PCR. Mol. Cellul. Probes. 12, 235-238.]. A real-time PCR was developed to detect L. pneumophila whereas a real-time NASBA was designed to detect Legionella spp. All samples with discordant results were re-analysed. Compared to an expanded gold standard the sensitivities of the different techniques, were 77.8%, 100%, and 100% for detection of M. pneumoniae; and 50%, 100%, and 50% for detection of L. pneumophila by PCR, real-time simplex NASBA, and real-time multiplex NASBA, respectively. C. pneumoniae was detected in two samples only. Simplex real-time NASBA proved to be more sensitive than simplex PCR and was also more sensitive than real-time multiplex NASBA, as previously found with spiked clinical specimens. It's practical attractiveness pleads for further optimalisation of the multiplex approach. SN - 0167-7012 UR - https://www.unboundmedicine.com/medline/citation/18378345/Evaluation_of_different_nucleic_acid_amplification_techniques_for_the_detection_of_M__pneumoniae_C__pneumoniae_and_Legionella_spp__in_respiratory_specimens_from_patients_with_community_acquired_pneumonia_ DB - PRIME DP - Unbound Medicine ER -