Tags

Type your tag names separated by a space and hit enter

Transient-evoked otoacoustic emissions in a group of professional singers who have normal pure-tone hearing thresholds.
Ear Hear. 2008 Jun; 29(3):360-77.EH

Abstract

OBJECTIVES

The objective of this study was to determine whether transient-evoked otoacoustic emissions (TEOAEs) measured in a group of normal-hearing professional singers, who were frequently exposed to high-level sound during rehearsals and performances, differed from those measured in age- and gender-matched normal-hearing non-singers, who were at minimal risk of hearing loss resulting from excessive sound exposure or other risk factors.

DESIGN

Twenty-three normal-hearing singers (NH-Ss), 23 normal-hearing controls (NH-Cs), and 9 hearing-impaired singers (HI-Ss) were included. Pure-tone audiometry confirmed normal-hearing thresholds (>or=15 dB HL) at 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, and 8.0 kHz in NH-Ss and NH-Cs, and confirmed mild, high frequency, sensorineural hearing loss in HI-Ss (HI-Ss were included only to estimate sensitivity and specificity values for preliminary pass or fail criteria that could be used to help identify NH-Ss at risk for music-induced hearing loss). TEOAEs were measured twice in all ears. TEOAE signal to noise ratio (S/N) and reproducibility were examined for the whole wave response, and for frequency bands centered at 1.0, 1.4, 2.0, 2.8, and 4.0 kHz.

RESULTS

Moderate to high correlations were found between test and retest TEOAE responses for the three groups. However, absolute test-retest differences revealed standard deviations that were two to three times larger than those reported previously, with the majority of the variability occurring for the 1.0 kHz band. As such, only the best TEOAE response (B-TEOAE) from the two measurements in each ear was used in further analyses, with data from the 1.0 kHz band excluded. With one exception, within-group comparisons of B-TEOAE S/N and reproducibility across ears and gender revealed no statistically significant differences for either NH-Ss or NH-Cs. The only significant within-group difference was between left and right ears of NH-C females for S/Ns measured in the 2.0 kHz band, where median responses from right ears were found to be higher than left ears. Across-group comparisons of B-TEOAEs revealed lower median S/N and reproducibility values for NH-Ss compared with NH-Cs for the whole wave response and 1.4 kHz band. For the 2.0 kHz band, reproducibility was similar for the normal-hearing groups but median S/N was found to be lower for NH-Ss. No significant differences in S/N or reproducibility were found between normal-hearing groups for the 2.8 and 4.0 kHz bands. Using data from NH-Cs and HI-Ss to establish sensitivity and specificity values for various TEOAE pass or fail criteria, six preliminary criteria were identified as having sensitivity and specificity values >or=90%. When these criteria were applied to NH-Ss, the number of NH-S ears passing ranged from 57% to 76%, depending on the criteria used to judge the NH-S ears, which translates into 24% to 43% of ears failing.

CONCLUSIONS

Although TEOAE responses were measurable in all singers with normal audiometric thresholds, responses were less robust than those of NH-Cs. The findings suggest that subtle cochlear dysfunction can be detected with TEOAE measurement in a subset of normal-hearing professional singers. Although preliminary, the study findings highlight the importance of pass or fail criterion choice on the number of ears that will be identified as "at risk" for music-induced hearing loss.

Authors+Show Affiliations

American University of Beirut Medical Center, Hamra, Beirut, Lebanon. alhamdan@scvlb.comNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article

Language

eng

PubMed ID

18382377

Citation

Hamdan, Abdul-Latif, et al. "Transient-evoked Otoacoustic Emissions in a Group of Professional Singers Who Have Normal Pure-tone Hearing Thresholds." Ear and Hearing, vol. 29, no. 3, 2008, pp. 360-77.
Hamdan AL, Abouchacra KS, Zeki Al Hazzouri AG, et al. Transient-evoked otoacoustic emissions in a group of professional singers who have normal pure-tone hearing thresholds. Ear Hear. 2008;29(3):360-77.
Hamdan, A. L., Abouchacra, K. S., Zeki Al Hazzouri, A. G., & Zaytoun, G. (2008). Transient-evoked otoacoustic emissions in a group of professional singers who have normal pure-tone hearing thresholds. Ear and Hearing, 29(3), 360-77. https://doi.org/10.1097/AUD.0b013e31816a0d1e
Hamdan AL, et al. Transient-evoked Otoacoustic Emissions in a Group of Professional Singers Who Have Normal Pure-tone Hearing Thresholds. Ear Hear. 2008;29(3):360-77. PubMed PMID: 18382377.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Transient-evoked otoacoustic emissions in a group of professional singers who have normal pure-tone hearing thresholds. AU - Hamdan,Abdul-Latif, AU - Abouchacra,Kim S, AU - Zeki Al Hazzouri,Adina G, AU - Zaytoun,Georges, PY - 2008/4/3/pubmed PY - 2008/8/30/medline PY - 2008/4/3/entrez SP - 360 EP - 77 JF - Ear and hearing JO - Ear Hear VL - 29 IS - 3 N2 - OBJECTIVES: The objective of this study was to determine whether transient-evoked otoacoustic emissions (TEOAEs) measured in a group of normal-hearing professional singers, who were frequently exposed to high-level sound during rehearsals and performances, differed from those measured in age- and gender-matched normal-hearing non-singers, who were at minimal risk of hearing loss resulting from excessive sound exposure or other risk factors. DESIGN: Twenty-three normal-hearing singers (NH-Ss), 23 normal-hearing controls (NH-Cs), and 9 hearing-impaired singers (HI-Ss) were included. Pure-tone audiometry confirmed normal-hearing thresholds (>or=15 dB HL) at 0.5, 1.0, 2.0, 3.0, 4.0, 6.0, and 8.0 kHz in NH-Ss and NH-Cs, and confirmed mild, high frequency, sensorineural hearing loss in HI-Ss (HI-Ss were included only to estimate sensitivity and specificity values for preliminary pass or fail criteria that could be used to help identify NH-Ss at risk for music-induced hearing loss). TEOAEs were measured twice in all ears. TEOAE signal to noise ratio (S/N) and reproducibility were examined for the whole wave response, and for frequency bands centered at 1.0, 1.4, 2.0, 2.8, and 4.0 kHz. RESULTS: Moderate to high correlations were found between test and retest TEOAE responses for the three groups. However, absolute test-retest differences revealed standard deviations that were two to three times larger than those reported previously, with the majority of the variability occurring for the 1.0 kHz band. As such, only the best TEOAE response (B-TEOAE) from the two measurements in each ear was used in further analyses, with data from the 1.0 kHz band excluded. With one exception, within-group comparisons of B-TEOAE S/N and reproducibility across ears and gender revealed no statistically significant differences for either NH-Ss or NH-Cs. The only significant within-group difference was between left and right ears of NH-C females for S/Ns measured in the 2.0 kHz band, where median responses from right ears were found to be higher than left ears. Across-group comparisons of B-TEOAEs revealed lower median S/N and reproducibility values for NH-Ss compared with NH-Cs for the whole wave response and 1.4 kHz band. For the 2.0 kHz band, reproducibility was similar for the normal-hearing groups but median S/N was found to be lower for NH-Ss. No significant differences in S/N or reproducibility were found between normal-hearing groups for the 2.8 and 4.0 kHz bands. Using data from NH-Cs and HI-Ss to establish sensitivity and specificity values for various TEOAE pass or fail criteria, six preliminary criteria were identified as having sensitivity and specificity values >or=90%. When these criteria were applied to NH-Ss, the number of NH-S ears passing ranged from 57% to 76%, depending on the criteria used to judge the NH-S ears, which translates into 24% to 43% of ears failing. CONCLUSIONS: Although TEOAE responses were measurable in all singers with normal audiometric thresholds, responses were less robust than those of NH-Cs. The findings suggest that subtle cochlear dysfunction can be detected with TEOAE measurement in a subset of normal-hearing professional singers. Although preliminary, the study findings highlight the importance of pass or fail criterion choice on the number of ears that will be identified as "at risk" for music-induced hearing loss. SN - 0196-0202 UR - https://www.unboundmedicine.com/medline/citation/18382377/Transient_evoked_otoacoustic_emissions_in_a_group_of_professional_singers_who_have_normal_pure_tone_hearing_thresholds_ DB - PRIME DP - Unbound Medicine ER -