Tags

Type your tag names separated by a space and hit enter

Coupling of solid-phase microextraction continuous bed (monolithic) capillaries with capillary zone electrophoresis for direct analysis of drugs in biological fluids.
Electrophoresis. 2008 Apr; 29(8):1753-60.E

Abstract

Hyperlink robust biocompatible solid-phase microextraction (SPME) devices were prepared using continuous bed (monolithic) restricted-access media (RAM) as the SPME capillary insert. The RAM-based SPME approach was able to simultaneously separate proteins from a biological sample, while directly extracting the active components of caffeine, paracetamol and acetylsalicylic acid from the drug NeoCitramonum. The devices were interfaced with a CZE system and fully automated analysis for sample preconcentration, desorption, separation and quantification of analytes was evaluated. Comparative study of in-line coupled SPME-CZE using RAM and RP capillary inserts was carried out. Using an SPME (RAM) insert, the calculated caffeine, paracetamol and acetylsalicylic acid LODs in a bovine plasma sample were 0.3, 0.8 and 1.9 ng/mL, respectively.

Authors+Show Affiliations

Department of Chemistry, Faculty of Natural Sciences, Vytautas Magnus University, Kaunas, Lithuania.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

18383020

Citation

Jarmalaviciene, Reda, et al. "Coupling of Solid-phase Microextraction Continuous Bed (monolithic) Capillaries With Capillary Zone Electrophoresis for Direct Analysis of Drugs in Biological Fluids." Electrophoresis, vol. 29, no. 8, 2008, pp. 1753-60.
Jarmalaviciene R, Szumski M, Kornysova O, et al. Coupling of solid-phase microextraction continuous bed (monolithic) capillaries with capillary zone electrophoresis for direct analysis of drugs in biological fluids. Electrophoresis. 2008;29(8):1753-60.
Jarmalaviciene, R., Szumski, M., Kornysova, O., Kłodzińska, E., Westerlund, D., Krawczyk, S., Mickevicius, D., Buszewski, B., & Maruska, A. (2008). Coupling of solid-phase microextraction continuous bed (monolithic) capillaries with capillary zone electrophoresis for direct analysis of drugs in biological fluids. Electrophoresis, 29(8), 1753-60. https://doi.org/10.1002/elps.200800046
Jarmalaviciene R, et al. Coupling of Solid-phase Microextraction Continuous Bed (monolithic) Capillaries With Capillary Zone Electrophoresis for Direct Analysis of Drugs in Biological Fluids. Electrophoresis. 2008;29(8):1753-60. PubMed PMID: 18383020.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Coupling of solid-phase microextraction continuous bed (monolithic) capillaries with capillary zone electrophoresis for direct analysis of drugs in biological fluids. AU - Jarmalaviciene,Reda, AU - Szumski,Michał, AU - Kornysova,Olga, AU - Kłodzińska,Ewa, AU - Westerlund,Douglas, AU - Krawczyk,Stanislas, AU - Mickevicius,Donatas, AU - Buszewski,Bogusław, AU - Maruska,Audrius, PY - 2008/4/3/pubmed PY - 2008/8/6/medline PY - 2008/4/3/entrez SP - 1753 EP - 60 JF - Electrophoresis JO - Electrophoresis VL - 29 IS - 8 N2 - Hyperlink robust biocompatible solid-phase microextraction (SPME) devices were prepared using continuous bed (monolithic) restricted-access media (RAM) as the SPME capillary insert. The RAM-based SPME approach was able to simultaneously separate proteins from a biological sample, while directly extracting the active components of caffeine, paracetamol and acetylsalicylic acid from the drug NeoCitramonum. The devices were interfaced with a CZE system and fully automated analysis for sample preconcentration, desorption, separation and quantification of analytes was evaluated. Comparative study of in-line coupled SPME-CZE using RAM and RP capillary inserts was carried out. Using an SPME (RAM) insert, the calculated caffeine, paracetamol and acetylsalicylic acid LODs in a bovine plasma sample were 0.3, 0.8 and 1.9 ng/mL, respectively. SN - 0173-0835 UR - https://www.unboundmedicine.com/medline/citation/18383020/Coupling_of_solid_phase_microextraction_continuous_bed__monolithic__capillaries_with_capillary_zone_electrophoresis_for_direct_analysis_of_drugs_in_biological_fluids_ DB - PRIME DP - Unbound Medicine ER -