Tags

Type your tag names separated by a space and hit enter

Influence of intermediate aminodextran layers on the signal response of surface acoustic wave biosensors.
Anal Biochem. 2008 Jun 15; 377(2):170-5.AB

Abstract

Surface acoustic wave (SAW) devices based on horizontally polarized surface shear waves enable direct and label-free detection of proteins in real time. Binding reactions on the sensor surface are detected by determining changes in surface wave velocity caused mainly by mass adsorption or change of viscoelasticity in the sensing layer. Intermediate hydrogel layers have been proven to be useful to immobilize capture molecules or ligands corresponding to the analyte. However, the SAW signal response strongly depends on the morphology of the hydrogel due to different relative changes of its acoustomechanical parameters such as viscoelasticity and density. In this work five aminodextrans (AMD) and one diamino polyethylene glycol (DA-PEG) were used as intermediate hydrogel layers. Sensors with immobilized streptavidin and samples containing biotinylated bovine serum albumin were used to exemplify affinity assays based on immobilized capture molecules for protein detection. The effects of the three-dimensional AMDs and the two-dimensional (2D) DA-PEG on the SAW signal response were investigated. The signal height decreased with increasing molar mass and increasing amount of immobilized AMD. Consequently, thin hydrogel layers are ideal to obtain optimum signal responses in this type of assay, whereas it is not necessarily a 2D hydrogel that gives the best results.

Authors+Show Affiliations

Institut für Mikrostrukturtechnik, Forschungszentrum Karlsruhe, PO Box 3640, 76021 Karlsruhe, Germany. kerstin.laenge@imt.fzk.deNo affiliation info available

Pub Type(s)

Journal Article

Language

eng

PubMed ID

18384737

Citation

Länge, Kerstin, and Michael Rapp. "Influence of Intermediate Aminodextran Layers On the Signal Response of Surface Acoustic Wave Biosensors." Analytical Biochemistry, vol. 377, no. 2, 2008, pp. 170-5.
Länge K, Rapp M. Influence of intermediate aminodextran layers on the signal response of surface acoustic wave biosensors. Anal Biochem. 2008;377(2):170-5.
Länge, K., & Rapp, M. (2008). Influence of intermediate aminodextran layers on the signal response of surface acoustic wave biosensors. Analytical Biochemistry, 377(2), 170-5. https://doi.org/10.1016/j.ab.2008.03.012
Länge K, Rapp M. Influence of Intermediate Aminodextran Layers On the Signal Response of Surface Acoustic Wave Biosensors. Anal Biochem. 2008 Jun 15;377(2):170-5. PubMed PMID: 18384737.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Influence of intermediate aminodextran layers on the signal response of surface acoustic wave biosensors. AU - Länge,Kerstin, AU - Rapp,Michael, Y1 - 2008/03/14/ PY - 2007/12/11/received PY - 2008/02/20/revised PY - 2008/03/09/accepted PY - 2008/4/4/pubmed PY - 2008/7/12/medline PY - 2008/4/4/entrez SP - 170 EP - 5 JF - Analytical biochemistry JO - Anal Biochem VL - 377 IS - 2 N2 - Surface acoustic wave (SAW) devices based on horizontally polarized surface shear waves enable direct and label-free detection of proteins in real time. Binding reactions on the sensor surface are detected by determining changes in surface wave velocity caused mainly by mass adsorption or change of viscoelasticity in the sensing layer. Intermediate hydrogel layers have been proven to be useful to immobilize capture molecules or ligands corresponding to the analyte. However, the SAW signal response strongly depends on the morphology of the hydrogel due to different relative changes of its acoustomechanical parameters such as viscoelasticity and density. In this work five aminodextrans (AMD) and one diamino polyethylene glycol (DA-PEG) were used as intermediate hydrogel layers. Sensors with immobilized streptavidin and samples containing biotinylated bovine serum albumin were used to exemplify affinity assays based on immobilized capture molecules for protein detection. The effects of the three-dimensional AMDs and the two-dimensional (2D) DA-PEG on the SAW signal response were investigated. The signal height decreased with increasing molar mass and increasing amount of immobilized AMD. Consequently, thin hydrogel layers are ideal to obtain optimum signal responses in this type of assay, whereas it is not necessarily a 2D hydrogel that gives the best results. SN - 1096-0309 UR - https://www.unboundmedicine.com/medline/citation/18384737/Influence_of_intermediate_aminodextran_layers_on_the_signal_response_of_surface_acoustic_wave_biosensors_ DB - PRIME DP - Unbound Medicine ER -