Tags

Type your tag names separated by a space and hit enter

Determination of aliphatic amines by high-performance liquid chromatography-amperometric detection after derivatization with naphthalene-2,3-dicarboxaldehyde.
Anal Chim Acta. 2008 May 05; 614(2):190-5.AC

Abstract

A simple and sensitive liquid chromatographic method has been developed for the determination of low molecular weight aliphatic amines after their pre-column derivatization with naphthalene-2,3-dicarboxaldehyde (NDA). Derivatization conditions, including the NDA concentration, reaction pH and reaction time have been investigated for method optimization. The chromatographic separation of five amines was performed on ABZ PLUS column using mobile phase of methanol-water (80:20, v/v) at a flow rate of 0.2 mL min(-1). The detection was carried out with a 6 mm glassy carbon electrode at the applied potential of 0.7 V versus Ag/AgCl reference electrode. The detection limits were between 23.3 and 34.4 nmol L(-1) of amines with a sample injection volume of 2 microL. The present method was applied for the determination of aliphatic amines in lake water. The recovery ranged 52.2-127.9%. The RSD in analytes retention time was less than 0.3% and 2.4% for intra- and inter-day analyses, respectively. The RSD in peak area was below 5.8% for both intra-day and inter-day analyses. The total analysis was completed within 20 min.

Authors+Show Affiliations

Microfluidics and MEMS Centre, Advanced Materials and Processes Research Institute, Bhopal 462026, India.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

18420050

Citation

Lamba, Sushma, et al. "Determination of Aliphatic Amines By High-performance Liquid Chromatography-amperometric Detection After Derivatization With Naphthalene-2,3-dicarboxaldehyde." Analytica Chimica Acta, vol. 614, no. 2, 2008, pp. 190-5.
Lamba S, Pandit A, Sanghi SK, et al. Determination of aliphatic amines by high-performance liquid chromatography-amperometric detection after derivatization with naphthalene-2,3-dicarboxaldehyde. Anal Chim Acta. 2008;614(2):190-5.
Lamba, S., Pandit, A., Sanghi, S. K., Gowri, V. S., Tiwari, A., Baderia, V. K., Singh, D. K., & Nigam, P. (2008). Determination of aliphatic amines by high-performance liquid chromatography-amperometric detection after derivatization with naphthalene-2,3-dicarboxaldehyde. Analytica Chimica Acta, 614(2), 190-5. https://doi.org/10.1016/j.aca.2008.03.011
Lamba S, et al. Determination of Aliphatic Amines By High-performance Liquid Chromatography-amperometric Detection After Derivatization With Naphthalene-2,3-dicarboxaldehyde. Anal Chim Acta. 2008 May 5;614(2):190-5. PubMed PMID: 18420050.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Determination of aliphatic amines by high-performance liquid chromatography-amperometric detection after derivatization with naphthalene-2,3-dicarboxaldehyde. AU - Lamba,Sushma, AU - Pandit,Arti, AU - Sanghi,Sunil Kumar, AU - Gowri,V Sorna, AU - Tiwari,Ankita, AU - Baderia,Vishal Kumar, AU - Singh,Deepesh Kumar, AU - Nigam,Preeti, Y1 - 2008/03/14/ PY - 2007/11/12/received PY - 2008/03/10/revised PY - 2008/03/10/accepted PY - 2008/4/19/pubmed PY - 2008/6/11/medline PY - 2008/4/19/entrez SP - 190 EP - 5 JF - Analytica chimica acta JO - Anal Chim Acta VL - 614 IS - 2 N2 - A simple and sensitive liquid chromatographic method has been developed for the determination of low molecular weight aliphatic amines after their pre-column derivatization with naphthalene-2,3-dicarboxaldehyde (NDA). Derivatization conditions, including the NDA concentration, reaction pH and reaction time have been investigated for method optimization. The chromatographic separation of five amines was performed on ABZ PLUS column using mobile phase of methanol-water (80:20, v/v) at a flow rate of 0.2 mL min(-1). The detection was carried out with a 6 mm glassy carbon electrode at the applied potential of 0.7 V versus Ag/AgCl reference electrode. The detection limits were between 23.3 and 34.4 nmol L(-1) of amines with a sample injection volume of 2 microL. The present method was applied for the determination of aliphatic amines in lake water. The recovery ranged 52.2-127.9%. The RSD in analytes retention time was less than 0.3% and 2.4% for intra- and inter-day analyses, respectively. The RSD in peak area was below 5.8% for both intra-day and inter-day analyses. The total analysis was completed within 20 min. SN - 1873-4324 UR - https://www.unboundmedicine.com/medline/citation/18420050/Determination_of_aliphatic_amines_by_high_performance_liquid_chromatography_amperometric_detection_after_derivatization_with_naphthalene_23_dicarboxaldehyde_ DB - PRIME DP - Unbound Medicine ER -