Tags

Type your tag names separated by a space and hit enter

Analysis of currently used pesticides in fine airborne particulate matter (PM 2.5) by pressurized liquid extraction and liquid chromatography-tandem mass spectrometry.
J Chromatogr A. 2008 Jul 25; 1200(2):100-7.JC

Abstract

During and after the application of currently used pesticides (CUPs) a significant fraction of applied pesticides can be lost to the air. A confirmatory and rapid procedure has been developed for the determination of four fungicides (carbendazim, thiabendazol, imazalil and bitertanol), three insecticides (imidacloprid, methidathion and pyriproxyfen), one helicide (methiocarb) and one acaricide (hexythiazox) in fine airborne particulate matter (PM 2.5) at trace level. The proposed method includes extraction of PM 2.5-bound pesticides by pressurized liquid extraction (PLE) followed by a direct injection into LC-MS/MS. The main parameters affecting the performance of the electrospray ionization source and PLE parameters were optimised using statistical design of experiments (DoE). The matrix effect was also evaluated. Recoveries ranged from 86 to 106% and the limit of quantification (LoQ) was 6.5 pg m(-3) for eight out of nine pesticides, when air volumes of 760 m(3) were collected. The method was applied to 60 samples collected from four stations of the monitoring network of the Regional Valencia Government (Spain) during August-October 2007. The measured concentrations ranged from not detected to 1,371 pg m(-3).

Authors+Show Affiliations

Public Health Laboratory of Valencia, Generalitat Valenciana, C/ Micer Mascó 31, 46010 Valencia, Spain.No affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

18573498

Citation

Coscollà, Clara, et al. "Analysis of Currently Used Pesticides in Fine Airborne Particulate Matter (PM 2.5) By Pressurized Liquid Extraction and Liquid Chromatography-tandem Mass Spectrometry." Journal of Chromatography. A, vol. 1200, no. 2, 2008, pp. 100-7.
Coscollà C, Yusà V, Martí P, et al. Analysis of currently used pesticides in fine airborne particulate matter (PM 2.5) by pressurized liquid extraction and liquid chromatography-tandem mass spectrometry. J Chromatogr A. 2008;1200(2):100-7.
Coscollà, C., Yusà, V., Martí, P., & Pastor, A. (2008). Analysis of currently used pesticides in fine airborne particulate matter (PM 2.5) by pressurized liquid extraction and liquid chromatography-tandem mass spectrometry. Journal of Chromatography. A, 1200(2), 100-7. https://doi.org/10.1016/j.chroma.2008.05.075
Coscollà C, et al. Analysis of Currently Used Pesticides in Fine Airborne Particulate Matter (PM 2.5) By Pressurized Liquid Extraction and Liquid Chromatography-tandem Mass Spectrometry. J Chromatogr A. 2008 Jul 25;1200(2):100-7. PubMed PMID: 18573498.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Analysis of currently used pesticides in fine airborne particulate matter (PM 2.5) by pressurized liquid extraction and liquid chromatography-tandem mass spectrometry. AU - Coscollà,Clara, AU - Yusà,Vicent, AU - Martí,Pedro, AU - Pastor,Agustin, Y1 - 2008/06/21/ PY - 2008/03/13/received PY - 2008/05/09/revised PY - 2008/05/14/accepted PY - 2008/6/25/pubmed PY - 2008/9/27/medline PY - 2008/6/25/entrez SP - 100 EP - 7 JF - Journal of chromatography. A JO - J Chromatogr A VL - 1200 IS - 2 N2 - During and after the application of currently used pesticides (CUPs) a significant fraction of applied pesticides can be lost to the air. A confirmatory and rapid procedure has been developed for the determination of four fungicides (carbendazim, thiabendazol, imazalil and bitertanol), three insecticides (imidacloprid, methidathion and pyriproxyfen), one helicide (methiocarb) and one acaricide (hexythiazox) in fine airborne particulate matter (PM 2.5) at trace level. The proposed method includes extraction of PM 2.5-bound pesticides by pressurized liquid extraction (PLE) followed by a direct injection into LC-MS/MS. The main parameters affecting the performance of the electrospray ionization source and PLE parameters were optimised using statistical design of experiments (DoE). The matrix effect was also evaluated. Recoveries ranged from 86 to 106% and the limit of quantification (LoQ) was 6.5 pg m(-3) for eight out of nine pesticides, when air volumes of 760 m(3) were collected. The method was applied to 60 samples collected from four stations of the monitoring network of the Regional Valencia Government (Spain) during August-October 2007. The measured concentrations ranged from not detected to 1,371 pg m(-3). SN - 0021-9673 UR - https://www.unboundmedicine.com/medline/citation/18573498/Analysis_of_currently_used_pesticides_in_fine_airborne_particulate_matter__PM_2_5__by_pressurized_liquid_extraction_and_liquid_chromatography_tandem_mass_spectrometry_ L2 - https://linkinghub.elsevier.com/retrieve/pii/S0021-9673(08)00879-0 DB - PRIME DP - Unbound Medicine ER -