A lamp light-emitting diode-induced fluorescence detector for capillary electrophoresis.Talanta. 2008 Jul 15; 76(2):369-72.T
Abstract
A light-emitting diode-induced fluorescence detector (LED-FD) for capillary electrophoresis was constructed and evaluated. A lamp LED with an enhanced emission spectrum and a band pass filter was used as the excitation light source. Refractive index matching fluid (RIMF) was used in the detection cell to reduce scattering light and the noise level. The limit of detection (LOD) for fluorescein was 1.5 nM (SNR=3). The system exhibited linear responses in the range of 1 x 10(-8) to 5 x 10(-6)M (R=0.999). Application of the lamp LED-FD for the analysis of FITC-labeled ephedra herb extract by capillary electrophoresis was demonstrated.
Links
Pub Type(s)
Evaluation Study
Journal Article
Research Support, Non-U.S. Gov't
Language
eng
PubMed ID
18585292
Citation
Xu, Jing, et al. "A Lamp Light-emitting Diode-induced Fluorescence Detector for Capillary Electrophoresis." Talanta, vol. 76, no. 2, 2008, pp. 369-72.
Xu J, Xiong Y, Chen S, et al. A lamp light-emitting diode-induced fluorescence detector for capillary electrophoresis. Talanta. 2008;76(2):369-72.
Xu, J., Xiong, Y., Chen, S., & Guan, Y. (2008). A lamp light-emitting diode-induced fluorescence detector for capillary electrophoresis. Talanta, 76(2), 369-72. https://doi.org/10.1016/j.talanta.2008.03.027
Xu J, et al. A Lamp Light-emitting Diode-induced Fluorescence Detector for Capillary Electrophoresis. Talanta. 2008 Jul 15;76(2):369-72. PubMed PMID: 18585292.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR
T1 - A lamp light-emitting diode-induced fluorescence detector for capillary electrophoresis.
AU - Xu,Jing,
AU - Xiong,Yan,
AU - Chen,Shiheng,
AU - Guan,Yafeng,
Y1 - 2008/03/26/
PY - 2007/12/19/received
PY - 2008/03/10/revised
PY - 2008/03/11/accepted
PY - 2008/7/1/pubmed
PY - 2008/8/14/medline
PY - 2008/7/1/entrez
SP - 369
EP - 72
JF - Talanta
JO - Talanta
VL - 76
IS - 2
N2 - A light-emitting diode-induced fluorescence detector (LED-FD) for capillary electrophoresis was constructed and evaluated. A lamp LED with an enhanced emission spectrum and a band pass filter was used as the excitation light source. Refractive index matching fluid (RIMF) was used in the detection cell to reduce scattering light and the noise level. The limit of detection (LOD) for fluorescein was 1.5 nM (SNR=3). The system exhibited linear responses in the range of 1 x 10(-8) to 5 x 10(-6)M (R=0.999). Application of the lamp LED-FD for the analysis of FITC-labeled ephedra herb extract by capillary electrophoresis was demonstrated.
SN - 1873-3573
UR - https://www.unboundmedicine.com/medline/citation/18585292/A_lamp_light_emitting_diode_induced_fluorescence_detector_for_capillary_electrophoresis_
L2 - https://linkinghub.elsevier.com/retrieve/pii/S0039-9140(08)00188-4
DB - PRIME
DP - Unbound Medicine
ER -