[The fabrication of hepatitis B electrochemical immunosensor array].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2008 Apr; 25(2):450-3.SW
Abstract
Based on integrate circuit (IC) technology, an eight-channel gold electrodes (GEs) array was developed. The immunosensor array is prepared by co-immobilizing thionine and Hepatitis B (HB) antibody on the gold electrodes through covalently binding them to GEs with a cysteamine/glutaraldehyde linkage. Hepatitis B surface antigen (HBsAg) was detected qualitatively and quantitatively by the peak current decrease percentage of the thionine. HBsAg positive/negative standard serum was well defined by the array. 8-channel synchronous detection for HBsAg was noted to be of good accuracy and reliability. The results of its clinical application were in good agreement with the results from ELISA.
MeSH
Pub Type(s)
English Abstract
Journal Article
Research Support, Non-U.S. Gov't
Language
chi
PubMed ID
18610640
Citation
Dai, Xiaofeng, and Zhongming Liu. "[The Fabrication of Hepatitis B Electrochemical Immunosensor Array]." Sheng Wu Yi Xue Gong Cheng Xue Za Zhi = Journal of Biomedical Engineering = Shengwu Yixue Gongchengxue Zazhi, vol. 25, no. 2, 2008, pp. 450-3.
Dai X, Liu Z. [The fabrication of hepatitis B electrochemical immunosensor array]. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2008;25(2):450-3.
Dai, X., & Liu, Z. (2008). [The fabrication of hepatitis B electrochemical immunosensor array]. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi = Journal of Biomedical Engineering = Shengwu Yixue Gongchengxue Zazhi, 25(2), 450-3.
Dai X, Liu Z. [The Fabrication of Hepatitis B Electrochemical Immunosensor Array]. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2008;25(2):450-3. PubMed PMID: 18610640.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR
T1 - [The fabrication of hepatitis B electrochemical immunosensor array].
AU - Dai,Xiaofeng,
AU - Liu,Zhongming,
PY - 2008/7/10/pubmed
PY - 2009/6/24/medline
PY - 2008/7/10/entrez
SP - 450
EP - 3
JF - Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi
JO - Sheng Wu Yi Xue Gong Cheng Xue Za Zhi
VL - 25
IS - 2
N2 - Based on integrate circuit (IC) technology, an eight-channel gold electrodes (GEs) array was developed. The immunosensor array is prepared by co-immobilizing thionine and Hepatitis B (HB) antibody on the gold electrodes through covalently binding them to GEs with a cysteamine/glutaraldehyde linkage. Hepatitis B surface antigen (HBsAg) was detected qualitatively and quantitatively by the peak current decrease percentage of the thionine. HBsAg positive/negative standard serum was well defined by the array. 8-channel synchronous detection for HBsAg was noted to be of good accuracy and reliability. The results of its clinical application were in good agreement with the results from ELISA.
SN - 1001-5515