A novel cheap and simple amperometric glucose biosensor, based on the electrode modified with the Ni/Al layered double hydroxide (LDH) nanoflakes and chitosan (CHT), without glucose oxidase, is presented. The glucose biosensor based on monodispersed high active Ni/Al-LDH nanoflakes and CHT exhibits an appropriate linear range of 0.01-10mM and good operational stability. The amperometric sensor shows a rapid response at the potential value 0.48V. In addition, optimization of the biosensor construction, the effects of the applied potential, the scan rate as well as common interfering compounds on the amperometric response and human serum samples analysis of the sensor were investigated and discussed.

Authors+Show Affiliations

Department of Physics, Central China Normal University, Wuhan 430079, PR China.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

18782662

Citation

Ai, Hanhua, et al. "A Novel Glucose Sensor Based On Monodispersed Ni/Al Layered Double Hydroxide and Chitosan." Biosensors & Bioelectronics, vol. 24, no. 4, 2008, pp. 1054-8.
Ai H, Huang X, Zhu Z, et al. A novel glucose sensor based on monodispersed Ni/Al layered double hydroxide and chitosan. Biosens Bioelectron. 2008;24(4):1054-8.
Ai, H., Huang, X., Zhu, Z., Liu, J., Chi, Q., Li, Y., Li, Z., & Ji, X. (2008). A novel glucose sensor based on monodispersed Ni/Al layered double hydroxide and chitosan. Biosensors & Bioelectronics, 24(4), 1054-8. https://doi.org/10.1016/j.bios.2008.07.039
Ai H, et al. A Novel Glucose Sensor Based On Monodispersed Ni/Al Layered Double Hydroxide and Chitosan. Biosens Bioelectron. 2008 Dec 1;24(4):1054-8. PubMed PMID: 18782662.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - A novel glucose sensor based on monodispersed Ni/Al layered double hydroxide and chitosan. AU - Ai,Hanhua, AU - Huang,Xintang, AU - Zhu,Zhihong, AU - Liu,Jinping, AU - Chi,Qingbo, AU - Li,Yuanyuan, AU - Li,Zikun, AU - Ji,Xiaoxu, Y1 - 2008/08/05/ PY - 2008/05/14/received PY - 2008/07/11/revised PY - 2008/07/22/accepted PY - 2008/9/11/pubmed PY - 2009/2/13/medline PY - 2008/9/11/entrez SP - 1054 EP - 8 JF - Biosensors & bioelectronics JO - Biosens Bioelectron VL - 24 IS - 4 N2 - A novel cheap and simple amperometric glucose biosensor, based on the electrode modified with the Ni/Al layered double hydroxide (LDH) nanoflakes and chitosan (CHT), without glucose oxidase, is presented. The glucose biosensor based on monodispersed high active Ni/Al-LDH nanoflakes and CHT exhibits an appropriate linear range of 0.01-10mM and good operational stability. The amperometric sensor shows a rapid response at the potential value 0.48V. In addition, optimization of the biosensor construction, the effects of the applied potential, the scan rate as well as common interfering compounds on the amperometric response and human serum samples analysis of the sensor were investigated and discussed. SN - 1873-4235 UR - https://www.unboundmedicine.com/medline/citation/18782662/A_novel_glucose_sensor_based_on_monodispersed_Ni/Al_layered_double_hydroxide_and_chitosan_ L2 - https://linkinghub.elsevier.com/retrieve/pii/S0956-5663(08)00408-9 DB - PRIME DP - Unbound Medicine ER -