Abstract

STUDY OBJECTIVE

To evaluate the performance of the Pentax-AWS airway scope for tracheal intubation compared with the Macintosh laryngoscope by non-anesthesia residents.

DESIGN

Prospective, randomized, cohort study.

SETTING

University-affiliated hospital.

PATIENTS

520 patients who underwent tracheal intubation for general anesthesia.

INTERVENTIONS

48 non-anesthesia residents performed tracheal intubation using either the Pentax-AWS or the Macintosh laryngoscope.

MEASUREMENTS

Time to complete tracheal intubation, number of attempts until successful intubation, and number of intubations of the esophagus were recorded.

RESULTS

Time to secure the airway (sec; mean +/- SD) was shorter with the Pentax-AWS than with the Macintosh laryngoscope (44 +/- 19 vs. 71 +/- 44 sec; P < 0.001). Of the 264 tracheal intubations with the Pentax-AWS, 239 (91%) were completed within 60 seconds, while only 148 (58%) of the 256 tracheal intubations performed with the Macintosh laryngoscope were completed within the same period. The rate of successful intubations on the first attempt was higher with the Pentax-AWS than the Macintosh laryngoscope (P < 0.001). No esophageal intubation was experienced with the Pentax-AWS approach, while 18 occurred with the Macintosh laryngoscope (P < 0.001).

CONCLUSION

The Pentax-AWS appears to require less operator skill than the Macintosh laryngoscope. Use of the Pentax-AWS may reduce the time to secure the airway and the incidence of failed tracheal intubation by non-anesthesia residents.

Authors+Show Affiliations

Department of Anesthesiology and Critical Care Medicine, Jichi Medical University, Tochigi, 329-0498, Japan. yhira@jichi.ac.jpNo affiliation info available

Pub Type(s)

Comparative Study
Journal Article
Randomized Controlled Trial

Language

eng

PubMed ID

19502032

Citation

Hirabayashi, Yoshihiro, and Norimasa Seo. "Tracheal Intubation By Non-anesthesia Residents Using the Pentax-AWS Airway Scope and Macintosh Laryngoscope." Journal of Clinical Anesthesia, vol. 21, no. 4, 2009, pp. 268-71.
Hirabayashi Y, Seo N. Tracheal intubation by non-anesthesia residents using the Pentax-AWS airway scope and Macintosh laryngoscope. J Clin Anesth. 2009;21(4):268-71.
Hirabayashi, Y., & Seo, N. (2009). Tracheal intubation by non-anesthesia residents using the Pentax-AWS airway scope and Macintosh laryngoscope. Journal of Clinical Anesthesia, 21(4), 268-71. https://doi.org/10.1016/j.jclinane.2008.08.024
Hirabayashi Y, Seo N. Tracheal Intubation By Non-anesthesia Residents Using the Pentax-AWS Airway Scope and Macintosh Laryngoscope. J Clin Anesth. 2009;21(4):268-71. PubMed PMID: 19502032.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Tracheal intubation by non-anesthesia residents using the Pentax-AWS airway scope and Macintosh laryngoscope. AU - Hirabayashi,Yoshihiro, AU - Seo,Norimasa, Y1 - 2009/06/06/ PY - 2007/07/31/received PY - 2008/08/20/revised PY - 2008/08/21/accepted PY - 2009/6/9/entrez PY - 2009/6/9/pubmed PY - 2009/9/3/medline SP - 268 EP - 71 JF - Journal of clinical anesthesia JO - J Clin Anesth VL - 21 IS - 4 N2 - STUDY OBJECTIVE: To evaluate the performance of the Pentax-AWS airway scope for tracheal intubation compared with the Macintosh laryngoscope by non-anesthesia residents. DESIGN: Prospective, randomized, cohort study. SETTING: University-affiliated hospital. PATIENTS: 520 patients who underwent tracheal intubation for general anesthesia. INTERVENTIONS: 48 non-anesthesia residents performed tracheal intubation using either the Pentax-AWS or the Macintosh laryngoscope. MEASUREMENTS: Time to complete tracheal intubation, number of attempts until successful intubation, and number of intubations of the esophagus were recorded. RESULTS: Time to secure the airway (sec; mean +/- SD) was shorter with the Pentax-AWS than with the Macintosh laryngoscope (44 +/- 19 vs. 71 +/- 44 sec; P < 0.001). Of the 264 tracheal intubations with the Pentax-AWS, 239 (91%) were completed within 60 seconds, while only 148 (58%) of the 256 tracheal intubations performed with the Macintosh laryngoscope were completed within the same period. The rate of successful intubations on the first attempt was higher with the Pentax-AWS than the Macintosh laryngoscope (P < 0.001). No esophageal intubation was experienced with the Pentax-AWS approach, while 18 occurred with the Macintosh laryngoscope (P < 0.001). CONCLUSION: The Pentax-AWS appears to require less operator skill than the Macintosh laryngoscope. Use of the Pentax-AWS may reduce the time to secure the airway and the incidence of failed tracheal intubation by non-anesthesia residents. SN - 1873-4529 UR - https://www.unboundmedicine.com/medline/citation/19502032/Tracheal_intubation_by_non_anesthesia_residents_using_the_Pentax_AWS_airway_scope_and_Macintosh_laryngoscope_ L2 - https://linkinghub.elsevier.com/retrieve/pii/S0952-8180(09)00108-1 DB - PRIME DP - Unbound Medicine ER -