Fabrication of an auricular prosthesis using computed tomography and rapid prototyping technique.J Craniofac Surg. 2009 Jul; 20(4):1169-72.JC
Abstract
This article describes the use of computed tomography and rapid prototyping method to produce a wax pattern of a missing ear. Computed tomographic scans were obtained from the patient, and a three-dimensional digital image was produced using a computer-aided design software. Then, the image of the present ear was extracted, and its mirror image was obtained with the software. The pattern of the inverted three-dimensional cast was produced using a rapid prototyping machine. The cast was duplicated in wax of identical dimensions and shape of the opposing ear, and the auricular prosthesis was fabricated with traditional methods.
Links
MeSH
Pub Type(s)
Case Reports
Journal Article
Language
eng
PubMed ID
19553846
Citation
Karayazgan-Saracoglu, Banu, et al. "Fabrication of an Auricular Prosthesis Using Computed Tomography and Rapid Prototyping Technique." The Journal of Craniofacial Surgery, vol. 20, no. 4, 2009, pp. 1169-72.
Karayazgan-Saracoglu B, Gunay Y, Atay A. Fabrication of an auricular prosthesis using computed tomography and rapid prototyping technique. J Craniofac Surg. 2009;20(4):1169-72.
Karayazgan-Saracoglu, B., Gunay, Y., & Atay, A. (2009). Fabrication of an auricular prosthesis using computed tomography and rapid prototyping technique. The Journal of Craniofacial Surgery, 20(4), 1169-72. https://doi.org/10.1097/SCS.0b013e3181acdb95
Karayazgan-Saracoglu B, Gunay Y, Atay A. Fabrication of an Auricular Prosthesis Using Computed Tomography and Rapid Prototyping Technique. J Craniofac Surg. 2009;20(4):1169-72. PubMed PMID: 19553846.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR
T1 - Fabrication of an auricular prosthesis using computed tomography and rapid prototyping technique.
AU - Karayazgan-Saracoglu,Banu,
AU - Gunay,Yumushan,
AU - Atay,Arzu,
PY - 2009/6/26/entrez
PY - 2009/6/26/pubmed
PY - 2009/11/3/medline
SP - 1169
EP - 72
JF - The Journal of craniofacial surgery
JO - J Craniofac Surg
VL - 20
IS - 4
N2 - This article describes the use of computed tomography and rapid prototyping method to produce a wax pattern of a missing ear. Computed tomographic scans were obtained from the patient, and a three-dimensional digital image was produced using a computer-aided design software. Then, the image of the present ear was extracted, and its mirror image was obtained with the software. The pattern of the inverted three-dimensional cast was produced using a rapid prototyping machine. The cast was duplicated in wax of identical dimensions and shape of the opposing ear, and the auricular prosthesis was fabricated with traditional methods.
SN - 1536-3732
UR - https://www.unboundmedicine.com/medline/citation/19553846/Fabrication_of_an_auricular_prosthesis_using_computed_tomography_and_rapid_prototyping_technique_
L2 - https://doi.org/10.1097/SCS.0b013e3181acdb95
DB - PRIME
DP - Unbound Medicine
ER -