Tags

Type your tag names separated by a space and hit enter

Human clinical fitting study of the DexAide right ventricular assist device.
Artif Organs. 2009 Jul; 33(7):558-61.AO

Abstract

The DexAide right ventricular assist device (RVAD) has been developed as an implantable RVAD. The purpose of this study was to determine the final design and optimal anatomical placement of the DexAide RVAD when implanted simultaneously with either of two commercially available left ventricular assist devices (LVADs) in patients. A mock-up DexAide RVAD was used to assess configuration with each of two types of commercially available LVADs at the time of LVAD implantation in three human clinical cases. The pump body of the DexAide RVAD was placed either in the preperitoneal space or in the right thoracic cavity. The DexAide RVAD placed into the right thoracic cavity is suitable for use with the Novacor or HeartMate II LVADs. The results of this study will guide the finalization of the inflow cannula and optimal placement of the DexAide RVAD for human clinical trials.

Authors+Show Affiliations

Department of Thoracic and Cardiovascular Surgery, Lerner Research Institute, Cleveland Clinic, Cleveland, OH, USA.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article

Language

eng

PubMed ID

19566734

Citation

Ootaki, Yoshio, et al. "Human Clinical Fitting Study of the DexAide Right Ventricular Assist Device." Artificial Organs, vol. 33, no. 7, 2009, pp. 558-61.
Ootaki Y, Ootaki C, Massiello A, et al. Human clinical fitting study of the DexAide right ventricular assist device. Artif Organs. 2009;33(7):558-61.
Ootaki, Y., Ootaki, C., Massiello, A., Horvath, D., Chen, J. F., Mihaljevic, T., Navia, J. L., Smedira, N. G., Golding, L. A., & Fukamachi, K. (2009). Human clinical fitting study of the DexAide right ventricular assist device. Artificial Organs, 33(7), 558-61. https://doi.org/10.1111/j.1525-1594.2009.00741.x
Ootaki Y, et al. Human Clinical Fitting Study of the DexAide Right Ventricular Assist Device. Artif Organs. 2009;33(7):558-61. PubMed PMID: 19566734.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Human clinical fitting study of the DexAide right ventricular assist device. AU - Ootaki,Yoshio, AU - Ootaki,Chiyo, AU - Massiello,Alex, AU - Horvath,David, AU - Chen,Ji-Feng, AU - Mihaljevic,Tomislav, AU - Navia,Jose L, AU - Smedira,Nicholas G, AU - Golding,Leonard A R, AU - Fukamachi,Kiyotaka, PY - 2009/7/2/entrez PY - 2009/7/2/pubmed PY - 2009/9/19/medline SP - 558 EP - 61 JF - Artificial organs JO - Artif Organs VL - 33 IS - 7 N2 - The DexAide right ventricular assist device (RVAD) has been developed as an implantable RVAD. The purpose of this study was to determine the final design and optimal anatomical placement of the DexAide RVAD when implanted simultaneously with either of two commercially available left ventricular assist devices (LVADs) in patients. A mock-up DexAide RVAD was used to assess configuration with each of two types of commercially available LVADs at the time of LVAD implantation in three human clinical cases. The pump body of the DexAide RVAD was placed either in the preperitoneal space or in the right thoracic cavity. The DexAide RVAD placed into the right thoracic cavity is suitable for use with the Novacor or HeartMate II LVADs. The results of this study will guide the finalization of the inflow cannula and optimal placement of the DexAide RVAD for human clinical trials. SN - 1525-1594 UR - https://www.unboundmedicine.com/medline/citation/19566734/Human_clinical_fitting_study_of_the_DexAide_right_ventricular_assist_device_ L2 - https://doi.org/10.1111/j.1525-1594.2009.00741.x DB - PRIME DP - Unbound Medicine ER -