Tags

Type your tag names separated by a space and hit enter

Enantiomeric separation of chiral dipeptides by CE-ESI-MS employing a partial filling technique with chiral crown ether.
Electrophoresis. 2009 Aug; 30(16):2837-44.E

Abstract

Enantiomer of chiral dipeptides were separated by CE-ESI-MS in a bare fused-silica capillary using (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid (18C6H4) as the chiral selector. As 18C6H4 is a kind of nonvolatile chiral selector, in order to prevent from 18C6H4 into the ion-source of CE-ESI-MS, a partial filling technique was employed in this study. Some dipeptides with one chiral center or two chiral centers, such as DL-Leu-DL-Leu, D-Ala-D-Ala and L-Ala-L-Ala, Gly-D-Phe and Gly-L-Phe were used to evaluate this CE-ESI-MS system. Optimized conditions were achivevd with 2.0 mol/L acetic acid (pH 2.15) as the running electrolyte, 5 mM 18C6H4 in 3.0 mol/L acetic acid (pH 2.00) was injected hydrodynamically (50 mbar for 960 s) before sample injection. In total 7.5 mM acetic acid in 80% v/v methanol-water was used as the sheath liquid, and 20 kV applied voltage was used. Under the optimum conditions, these dipeptides were separated and detected. LODs (defined as S/N=3) of this method were 0.20, 0.10, 0.05 and 0.10 micromol/L for D-Ala-D-Ala, L-Ala-L-Ala, DL-Leu-DL-Leu, Gly-L-Phe and Gly-D-Phe, respectively. The RSDs (n=7) of the method were 0.68-2.08% for migration times and 2.32-5.24% for peak areas. The proposed method was also successfully applied to the enantioselective analysis of these dipeptides in the spiked serum samples with satisfactory results.

Authors+Show Affiliations

Ministry of Education Key Laboratory of Analysis and Detection for Food Safety, Department of Chemistry, Fuzhou University, Fuzhou, Fujian, P. R. China.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

19655329

Citation

Xia, Shifei, et al. "Enantiomeric Separation of Chiral Dipeptides By CE-ESI-MS Employing a Partial Filling Technique With Chiral Crown Ether." Electrophoresis, vol. 30, no. 16, 2009, pp. 2837-44.
Xia S, Zhang L, Lu M, et al. Enantiomeric separation of chiral dipeptides by CE-ESI-MS employing a partial filling technique with chiral crown ether. Electrophoresis. 2009;30(16):2837-44.
Xia, S., Zhang, L., Lu, M., Qiu, B., Chi, Y., & Chen, G. (2009). Enantiomeric separation of chiral dipeptides by CE-ESI-MS employing a partial filling technique with chiral crown ether. Electrophoresis, 30(16), 2837-44. https://doi.org/10.1002/elps.200800799
Xia S, et al. Enantiomeric Separation of Chiral Dipeptides By CE-ESI-MS Employing a Partial Filling Technique With Chiral Crown Ether. Electrophoresis. 2009;30(16):2837-44. PubMed PMID: 19655329.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Enantiomeric separation of chiral dipeptides by CE-ESI-MS employing a partial filling technique with chiral crown ether. AU - Xia,Shifei, AU - Zhang,Lan, AU - Lu,Minghua, AU - Qiu,Bin, AU - Chi,Yuwu, AU - Chen,Guonan, PY - 2009/8/6/entrez PY - 2009/8/6/pubmed PY - 2010/1/6/medline SP - 2837 EP - 44 JF - Electrophoresis JO - Electrophoresis VL - 30 IS - 16 N2 - Enantiomer of chiral dipeptides were separated by CE-ESI-MS in a bare fused-silica capillary using (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid (18C6H4) as the chiral selector. As 18C6H4 is a kind of nonvolatile chiral selector, in order to prevent from 18C6H4 into the ion-source of CE-ESI-MS, a partial filling technique was employed in this study. Some dipeptides with one chiral center or two chiral centers, such as DL-Leu-DL-Leu, D-Ala-D-Ala and L-Ala-L-Ala, Gly-D-Phe and Gly-L-Phe were used to evaluate this CE-ESI-MS system. Optimized conditions were achivevd with 2.0 mol/L acetic acid (pH 2.15) as the running electrolyte, 5 mM 18C6H4 in 3.0 mol/L acetic acid (pH 2.00) was injected hydrodynamically (50 mbar for 960 s) before sample injection. In total 7.5 mM acetic acid in 80% v/v methanol-water was used as the sheath liquid, and 20 kV applied voltage was used. Under the optimum conditions, these dipeptides were separated and detected. LODs (defined as S/N=3) of this method were 0.20, 0.10, 0.05 and 0.10 micromol/L for D-Ala-D-Ala, L-Ala-L-Ala, DL-Leu-DL-Leu, Gly-L-Phe and Gly-D-Phe, respectively. The RSDs (n=7) of the method were 0.68-2.08% for migration times and 2.32-5.24% for peak areas. The proposed method was also successfully applied to the enantioselective analysis of these dipeptides in the spiked serum samples with satisfactory results. SN - 1522-2683 UR - https://www.unboundmedicine.com/medline/citation/19655329/Enantiomeric_separation_of_chiral_dipeptides_by_CE_ESI_MS_employing_a_partial_filling_technique_with_chiral_crown_ether_ L2 - https://doi.org/10.1002/elps.200800799 DB - PRIME DP - Unbound Medicine ER -