Tags

Type your tag names separated by a space and hit enter

Application of conventional solid-phase extraction for multimycotoxin analysis in beers by ultrahigh-performance liquid chromatography-tandem mass spectrometry.
J Agric Food Chem. 2009 Oct 28; 57(20):9385-92.JA

Abstract

A new analytical method has been developed and validated for the simultaneous analysis of mycotoxins (aflatoxins B1, B2, G1, G2, and M1, fumonisins B1 and B2, deoxynivalenol, ochratoxin A, HT-2 and T-2 toxins, and zearalenone) in beers. Mycotoxins were extracted by solid-phase extraction (SPE) using C18 as the cartridge. Several parameters such as type of sorbent, elution solvent, and dilution of the sample were evaluated. The separation and determination were carried out by ultrahigh performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). The method was validated, and mean recoveries ranging from 70 to 106% were obtained. Repeatability and intermediate precision, expressed as relative standard deviations, were lower than 21% for all mycotoxins and levels assayed. The limits of quantification were lower than 0.5 microg/L. The developed method has been applied for the analysis of several types of beers with different alcoholic content (nonalcoholic, normal, and special), and T2, HT-2 toxins, aflatoxin B1, and fumonisin B2 were detected. This methodology combines the simplicity of SPE using conventional cartridges and UHPLC-MS/MS, producing a rapid, sensitive, and reliable procedure.

Authors+Show Affiliations

Group Analytical Chemistry of Contaminants, Department of Analytical Chemistry, Almería University, E-04071 Almería, Spain.No affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Evaluation Study
Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

19788189

Citation

Romero-González, Roberto, et al. "Application of Conventional Solid-phase Extraction for Multimycotoxin Analysis in Beers By Ultrahigh-performance Liquid Chromatography-tandem Mass Spectrometry." Journal of Agricultural and Food Chemistry, vol. 57, no. 20, 2009, pp. 9385-92.
Romero-González R, Martínez Vidal JL, Aguilera-Luiz MM, et al. Application of conventional solid-phase extraction for multimycotoxin analysis in beers by ultrahigh-performance liquid chromatography-tandem mass spectrometry. J Agric Food Chem. 2009;57(20):9385-92.
Romero-González, R., Martínez Vidal, J. L., Aguilera-Luiz, M. M., & Garrido Frenich, A. (2009). Application of conventional solid-phase extraction for multimycotoxin analysis in beers by ultrahigh-performance liquid chromatography-tandem mass spectrometry. Journal of Agricultural and Food Chemistry, 57(20), 9385-92. https://doi.org/10.1021/jf903154a
Romero-González R, et al. Application of Conventional Solid-phase Extraction for Multimycotoxin Analysis in Beers By Ultrahigh-performance Liquid Chromatography-tandem Mass Spectrometry. J Agric Food Chem. 2009 Oct 28;57(20):9385-92. PubMed PMID: 19788189.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Application of conventional solid-phase extraction for multimycotoxin analysis in beers by ultrahigh-performance liquid chromatography-tandem mass spectrometry. AU - Romero-González,Roberto, AU - Martínez Vidal,Jose Luis, AU - Aguilera-Luiz,M M, AU - Garrido Frenich,Antonia, PY - 2009/10/1/entrez PY - 2009/10/1/pubmed PY - 2010/10/5/medline SP - 9385 EP - 92 JF - Journal of agricultural and food chemistry JO - J Agric Food Chem VL - 57 IS - 20 N2 - A new analytical method has been developed and validated for the simultaneous analysis of mycotoxins (aflatoxins B1, B2, G1, G2, and M1, fumonisins B1 and B2, deoxynivalenol, ochratoxin A, HT-2 and T-2 toxins, and zearalenone) in beers. Mycotoxins were extracted by solid-phase extraction (SPE) using C18 as the cartridge. Several parameters such as type of sorbent, elution solvent, and dilution of the sample were evaluated. The separation and determination were carried out by ultrahigh performance liquid chromatography coupled to tandem mass spectrometry (UHPLC-MS/MS). The method was validated, and mean recoveries ranging from 70 to 106% were obtained. Repeatability and intermediate precision, expressed as relative standard deviations, were lower than 21% for all mycotoxins and levels assayed. The limits of quantification were lower than 0.5 microg/L. The developed method has been applied for the analysis of several types of beers with different alcoholic content (nonalcoholic, normal, and special), and T2, HT-2 toxins, aflatoxin B1, and fumonisin B2 were detected. This methodology combines the simplicity of SPE using conventional cartridges and UHPLC-MS/MS, producing a rapid, sensitive, and reliable procedure. SN - 1520-5118 UR - https://www.unboundmedicine.com/medline/citation/19788189/Application_of_conventional_solid_phase_extraction_for_multimycotoxin_analysis_in_beers_by_ultrahigh_performance_liquid_chromatography_tandem_mass_spectrometry_ L2 - https://doi.org/10.1021/jf903154a DB - PRIME DP - Unbound Medicine ER -