Tags

Type your tag names separated by a space and hit enter

Mechanical effects of implant-tooth rigid connection by a fixed partial denture: a 3d finite element analysis.
Eur J Prosthodont Restor Dent. 2009 Sep; 17(3):98-104.EJ

Abstract

This study investigated the mechanical behaviour of tooth-implant fixed partial dentures by three-dimensional Finite Element Analysis. Titanium implants of various length and diameter were rigidly connected to a premolar either by two connected ceramic crowns or by a three unit Fixed Partial Denture. The implant acted like the fulcrum of an orthodontic device inducing tooth intrusion. Bone stresses appeared around the neck of the implant. Implant and abutment's stresses were meaningfully less intense with high diameter and low span. Implant length was a less influencing parameter. The use of wide-bodied implants is recommended in selected cases of short-span fixed partial dentures.

Authors+Show Affiliations

Hopital Bretonneau, Paris Descartes University, Paris, France. adriennaveau@hotmail.comNo affiliation info available

Pub Type(s)

Journal Article

Language

eng

PubMed ID

19839184

Citation

Naveau, Adrien, and Laurent Pierrisnard. "Mechanical Effects of Implant-tooth Rigid Connection By a Fixed Partial Denture: a 3d Finite Element Analysis." The European Journal of Prosthodontics and Restorative Dentistry, vol. 17, no. 3, 2009, pp. 98-104.
Naveau A, Pierrisnard L. Mechanical effects of implant-tooth rigid connection by a fixed partial denture: a 3d finite element analysis. Eur J Prosthodont Restor Dent. 2009;17(3):98-104.
Naveau, A., & Pierrisnard, L. (2009). Mechanical effects of implant-tooth rigid connection by a fixed partial denture: a 3d finite element analysis. The European Journal of Prosthodontics and Restorative Dentistry, 17(3), 98-104.
Naveau A, Pierrisnard L. Mechanical Effects of Implant-tooth Rigid Connection By a Fixed Partial Denture: a 3d Finite Element Analysis. Eur J Prosthodont Restor Dent. 2009;17(3):98-104. PubMed PMID: 19839184.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Mechanical effects of implant-tooth rigid connection by a fixed partial denture: a 3d finite element analysis. AU - Naveau,Adrien, AU - Pierrisnard,Laurent, PY - 2009/10/21/entrez PY - 2009/10/21/pubmed PY - 2010/1/20/medline SP - 98 EP - 104 JF - The European journal of prosthodontics and restorative dentistry JO - Eur J Prosthodont Restor Dent VL - 17 IS - 3 N2 - This study investigated the mechanical behaviour of tooth-implant fixed partial dentures by three-dimensional Finite Element Analysis. Titanium implants of various length and diameter were rigidly connected to a premolar either by two connected ceramic crowns or by a three unit Fixed Partial Denture. The implant acted like the fulcrum of an orthodontic device inducing tooth intrusion. Bone stresses appeared around the neck of the implant. Implant and abutment's stresses were meaningfully less intense with high diameter and low span. Implant length was a less influencing parameter. The use of wide-bodied implants is recommended in selected cases of short-span fixed partial dentures. SN - 0965-7452 UR - https://www.unboundmedicine.com/medline/citation/19839184/Mechanical_effects_of_implant_tooth_rigid_connection_by_a_fixed_partial_denture:_a_3d_finite_element_analysis_ DB - PRIME DP - Unbound Medicine ER -