Citation
Manassra, Adnan, et al. "Simultaneous HPLC Analysis of Pseudophedrine Hydrochloride, Codeine Phosphate, and Triprolidine Hydrochloride in Liquid Dosage Forms." Journal of Pharmaceutical and Biomedical Analysis, vol. 51, no. 4, 2010, pp. 991-3.
Manassra A, Khamis M, El-Dakiky M, et al. Simultaneous HPLC analysis of pseudophedrine hydrochloride, codeine phosphate, and triprolidine hydrochloride in liquid dosage forms. J Pharm Biomed Anal. 2010;51(4):991-3.
Manassra, A., Khamis, M., El-Dakiky, M., Abdel-Qader, Z., & Al-Rimawi, F. (2010). Simultaneous HPLC analysis of pseudophedrine hydrochloride, codeine phosphate, and triprolidine hydrochloride in liquid dosage forms. Journal of Pharmaceutical and Biomedical Analysis, 51(4), 991-3. https://doi.org/10.1016/j.jpba.2009.10.024
Manassra A, et al. Simultaneous HPLC Analysis of Pseudophedrine Hydrochloride, Codeine Phosphate, and Triprolidine Hydrochloride in Liquid Dosage Forms. J Pharm Biomed Anal. 2010 Mar 11;51(4):991-3. PubMed PMID: 19954915.
TY - JOUR
T1 - Simultaneous HPLC analysis of pseudophedrine hydrochloride, codeine phosphate, and triprolidine hydrochloride in liquid dosage forms.
AU - Manassra,Adnan,
AU - Khamis,Mustafa,
AU - El-Dakiky,Magdy,
AU - Abdel-Qader,Zuhair,
AU - Al-Rimawi,Fuad,
Y1 - 2009/11/10/
PY - 2009/06/23/received
PY - 2009/10/03/revised
PY - 2009/10/30/accepted
PY - 2009/12/4/entrez
PY - 2009/12/4/pubmed
PY - 2010/4/9/medline
SP - 991
EP - 3
JF - Journal of pharmaceutical and biomedical analysis
JO - J Pharm Biomed Anal
VL - 51
IS - 4
N2 - An HPLC method using UV detection is proposed for the simultaneous determination of pseudophedrine hydrochloride, codeine phosphate, and triprolidine hydrochloride in liquid formulation. C18 column (250mmx4.0mm) is used as the stationary phase with a mixture of methanol:acetate buffer:acetonitrile (85:5:10, v/v) as the mobile phase. The factors affecting column separation of the analytes were studied. The calibration graphs exhibited a linear concentration range of 0.06-1.0mg/ml for pseudophedrine hydrochloride, 0.02-1.0mg/ml for codeine phosphate, and 0.0025-1.0mg/ml for triprolidine hydrochloride for a sample size of 5microl with correlation coefficients of better than 0.999 for all active ingredients studied. The results demonstrate that this method is reliable, reproducible and suitable for routine use with analysis time of less than 4min.
SN - 1873-264X
UR - https://www.unboundmedicine.com/medline/citation/19954915/Simultaneous_HPLC_analysis_of_pseudophedrine_hydrochloride_codeine_phosphate_and_triprolidine_hydrochloride_in_liquid_dosage_forms_
L2 - https://linkinghub.elsevier.com/retrieve/pii/S0731-7085(09)00693-1
DB - PRIME
DP - Unbound Medicine
ER -