Tags

Type your tag names separated by a space and hit enter

A liquid chromatography-atmospheric pressure photoionization tandem mass spectrometric method for the determination of azaarenes in atmospheric particulate matter.
J Chromatogr A. 2010 Mar 05; 1217(10):1636-46.JC

Abstract

The development, optimization and validation of a liquid chromatography-atmospheric pressure photoionization tandem mass spectrometric (LC-APPI/MS/MS) method for the determination of 15 azaarenes (4-azafluorene, benzo[h] and -[f]quinoline, phenanthridine, acridine, 1-azafluoranthene, 4-azapyrene, benz[a]- and -[c]acridine, -10-azabenzo[a]pyrene, 7,9- and 7,10-dimethylbenz[c]acridine, dibenz[a,j]-, -[c,h] and [a,i]acridine) in airborne particulate matter is described. Each compound was detected and quantified operating in multiple reaction monitoring mode. Extraction of azaarenes was achieved using accelerated solvent extraction (ASE) with dichlormethane/methanol (50/50, v/v). After extraction, no additional clean-up procedure like solid phase or liquid/liquid extraction was necessary. Limits of quantification (S/Nx10) ranged from 0.2 pg/microl to 1.4 pg/microl, matrix dependent recoveries were between 57% and 94%, with relative standard deviations from 8% to 17%. Applicability of the method was demonstrated analyzing 10 samples of particulate matter (PM(2.5)) collected in winter 2008. In all samples dimethylbenz[c]acridines as well as dibenzacridines were below the limit of quantification, concentration of the remaining analytes were in the range from 0.002 ng/m(3) to 0.356 ng/m(3).

Authors+Show Affiliations

Helmholtz Zentrum München, German Research Center for Environmental Health, Institute of Ecological Chemistry, Ingolstädter Landstr. 1, 85764 Neuherberg, Germany. lintelmann@helmholtz-muenchen.deNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Evaluation Study
Journal Article

Language

eng

PubMed ID

20122695

Citation

Lintelmann, Jutta, et al. "A Liquid Chromatography-atmospheric Pressure Photoionization Tandem Mass Spectrometric Method for the Determination of Azaarenes in Atmospheric Particulate Matter." Journal of Chromatography. A, vol. 1217, no. 10, 2010, pp. 1636-46.
Lintelmann J, França MH, Hübner E, et al. A liquid chromatography-atmospheric pressure photoionization tandem mass spectrometric method for the determination of azaarenes in atmospheric particulate matter. J Chromatogr A. 2010;1217(10):1636-46.
Lintelmann, J., França, M. H., Hübner, E., & Matuschek, G. (2010). A liquid chromatography-atmospheric pressure photoionization tandem mass spectrometric method for the determination of azaarenes in atmospheric particulate matter. Journal of Chromatography. A, 1217(10), 1636-46. https://doi.org/10.1016/j.chroma.2010.01.029
Lintelmann J, et al. A Liquid Chromatography-atmospheric Pressure Photoionization Tandem Mass Spectrometric Method for the Determination of Azaarenes in Atmospheric Particulate Matter. J Chromatogr A. 2010 Mar 5;1217(10):1636-46. PubMed PMID: 20122695.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - A liquid chromatography-atmospheric pressure photoionization tandem mass spectrometric method for the determination of azaarenes in atmospheric particulate matter. AU - Lintelmann,Jutta, AU - França,Monica Heil, AU - Hübner,Evelyn, AU - Matuschek,Georg, Y1 - 2010/01/18/ PY - 2009/10/08/received PY - 2009/12/17/revised PY - 2010/01/11/accepted PY - 2010/2/4/entrez PY - 2010/2/4/pubmed PY - 2010/4/27/medline SP - 1636 EP - 46 JF - Journal of chromatography. A JO - J Chromatogr A VL - 1217 IS - 10 N2 - The development, optimization and validation of a liquid chromatography-atmospheric pressure photoionization tandem mass spectrometric (LC-APPI/MS/MS) method for the determination of 15 azaarenes (4-azafluorene, benzo[h] and -[f]quinoline, phenanthridine, acridine, 1-azafluoranthene, 4-azapyrene, benz[a]- and -[c]acridine, -10-azabenzo[a]pyrene, 7,9- and 7,10-dimethylbenz[c]acridine, dibenz[a,j]-, -[c,h] and [a,i]acridine) in airborne particulate matter is described. Each compound was detected and quantified operating in multiple reaction monitoring mode. Extraction of azaarenes was achieved using accelerated solvent extraction (ASE) with dichlormethane/methanol (50/50, v/v). After extraction, no additional clean-up procedure like solid phase or liquid/liquid extraction was necessary. Limits of quantification (S/Nx10) ranged from 0.2 pg/microl to 1.4 pg/microl, matrix dependent recoveries were between 57% and 94%, with relative standard deviations from 8% to 17%. Applicability of the method was demonstrated analyzing 10 samples of particulate matter (PM(2.5)) collected in winter 2008. In all samples dimethylbenz[c]acridines as well as dibenzacridines were below the limit of quantification, concentration of the remaining analytes were in the range from 0.002 ng/m(3) to 0.356 ng/m(3). SN - 1873-3778 UR - https://www.unboundmedicine.com/medline/citation/20122695/A_liquid_chromatography_atmospheric_pressure_photoionization_tandem_mass_spectrometric_method_for_the_determination_of_azaarenes_in_atmospheric_particulate_matter_ L2 - https://linkinghub.elsevier.com/retrieve/pii/S0021-9673(10)00066-X DB - PRIME DP - Unbound Medicine ER -