[Computer aided design and manufacture of the removable partial denture framework].Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2010 Feb; 27(1):170-3.SW
Abstract
This paper demonstrates the successful application of a novel approach to the computer aided design (CAD) of removable partial denture (RPD) framework. Firstly, we get the data of the partially edentulous cast, a mandibular Kennedy Class II, through a 3D-optical grating measuring system after corresponding pretreatment. Then, the reverse engineering software and 3D CAD software was used to design basis, big conjunction, clasp, small conjunction of the RPD framework. Finally 3D surface model of the RPD framework was created in preparation for direct manufacture using rapid prototyping (RP) methods and foundry. The result indicated that the RPD framework was fabricated successfully and the resulting frameworks provided a satisfactory fit.
MeSH
Pub Type(s)
English Abstract
Journal Article
Language
chi
PubMed ID
20337047
Citation
Yang, Leilei, et al. "[Computer Aided Design and Manufacture of the Removable Partial Denture Framework]." Sheng Wu Yi Xue Gong Cheng Xue Za Zhi = Journal of Biomedical Engineering = Shengwu Yixue Gongchengxue Zazhi, vol. 27, no. 1, 2010, pp. 170-3.
Yang L, Cheng X, Dai N, et al. [Computer aided design and manufacture of the removable partial denture framework]. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2010;27(1):170-3.
Yang, L., Cheng, X., Dai, N., Zhu, S., Yan, G., & Gao, Y. (2010). [Computer aided design and manufacture of the removable partial denture framework]. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi = Journal of Biomedical Engineering = Shengwu Yixue Gongchengxue Zazhi, 27(1), 170-3.
Yang L, et al. [Computer Aided Design and Manufacture of the Removable Partial Denture Framework]. Sheng Wu Yi Xue Gong Cheng Xue Za Zhi. 2010;27(1):170-3. PubMed PMID: 20337047.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR
T1 - [Computer aided design and manufacture of the removable partial denture framework].
AU - Yang,Leilei,
AU - Cheng,Xiaosheng,
AU - Dai,Ning,
AU - Zhu,Senyang,
AU - Yan,Guodong,
AU - Gao,Yiguo,
PY - 2010/3/27/entrez
PY - 2010/3/27/pubmed
PY - 2012/1/10/medline
SP - 170
EP - 3
JF - Sheng wu yi xue gong cheng xue za zhi = Journal of biomedical engineering = Shengwu yixue gongchengxue zazhi
JO - Sheng Wu Yi Xue Gong Cheng Xue Za Zhi
VL - 27
IS - 1
N2 - This paper demonstrates the successful application of a novel approach to the computer aided design (CAD) of removable partial denture (RPD) framework. Firstly, we get the data of the partially edentulous cast, a mandibular Kennedy Class II, through a 3D-optical grating measuring system after corresponding pretreatment. Then, the reverse engineering software and 3D CAD software was used to design basis, big conjunction, clasp, small conjunction of the RPD framework. Finally 3D surface model of the RPD framework was created in preparation for direct manufacture using rapid prototyping (RP) methods and foundry. The result indicated that the RPD framework was fabricated successfully and the resulting frameworks provided a satisfactory fit.
SN - 1001-5515
UR - https://www.unboundmedicine.com/medline/citation/20337047/[Computer_aided_design_and_manufacture_of_the_removable_partial_denture_framework]_
DB - PRIME
DP - Unbound Medicine
ER -