Tags

Type your tag names separated by a space and hit enter

A multi-residue method for pesticide residue analysis in rice grains using matrix solid-phase dispersion extraction and high-performance liquid chromatography-diode array detection.
Anal Bioanal Chem. 2010 Jul; 397(6):2181-90.AB

Abstract

Pesticides are widely used in rice cultivation, often resulting in detection of their residues in rice grains. So far, no analytical method has been available for the simultaneous determination of most rice pesticides in rice grains. This paper reports the development and validation of such a method for the determination of eight rice pesticides (penoxsulam tricyclazole, propanil, azoxystrobin, molinate, profoxydim, cyhalofop-butyl, deltamethrin) and 3,4-dichloroaniline, the main metabolite of propanil. Pesticide extraction and clean-up was performed by an optimized matrix solid-phase dispersion (MSPD) protocol on neutral alumina (5 g) using acetonitrile as the elution solvent. Samples were analyzed in a high-performance liquid chromatography-diode array detection (HPLC-DAD) system. Pesticide separation was achieved with a mobile phase of acetonitrile/water in a linear elution gradient from 30:70% (v/v) to 100:0% (v/v) in 14 min at a flow rate of 0.8 mL min(-1). Method validation was performed by means of linearity, intra-day accuracy, inter-day precision and sensitivity. Linear regression coefficients (R(2)) were always above 0.9948. Limits of detection (LOD) and quantification (LOQ) varied from 0.002 to 0.200 mg kg(-1) and 0.006 to 0.600 mg kg(-1), respectively. Recoveries were investigated at three fortification levels and were found to be acceptable (74-127%) with relative standard deviations (RSD) below 12%. Application of the method for the analysis of five commercial rice grain samples showed that the pesticide levels were below the LOD. Overall, the method developed is suitable for the determination of residues of most rice pesticides in rice grains at levels below the established MRLs.

Authors+Show Affiliations

Analytical Chemistry Laboratory, Department of Chemical Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki, Greece.No affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article

Language

eng

PubMed ID

20379813

Citation

Tsochatzis, Emmanouil D., et al. "A Multi-residue Method for Pesticide Residue Analysis in Rice Grains Using Matrix Solid-phase Dispersion Extraction and High-performance Liquid Chromatography-diode Array Detection." Analytical and Bioanalytical Chemistry, vol. 397, no. 6, 2010, pp. 2181-90.
Tsochatzis ED, Menkissoglu-Spiroudi U, Karpouzas DG, et al. A multi-residue method for pesticide residue analysis in rice grains using matrix solid-phase dispersion extraction and high-performance liquid chromatography-diode array detection. Anal Bioanal Chem. 2010;397(6):2181-90.
Tsochatzis, E. D., Menkissoglu-Spiroudi, U., Karpouzas, D. G., & Tzimou-Tsitouridou, R. (2010). A multi-residue method for pesticide residue analysis in rice grains using matrix solid-phase dispersion extraction and high-performance liquid chromatography-diode array detection. Analytical and Bioanalytical Chemistry, 397(6), 2181-90. https://doi.org/10.1007/s00216-010-3645-4
Tsochatzis ED, et al. A Multi-residue Method for Pesticide Residue Analysis in Rice Grains Using Matrix Solid-phase Dispersion Extraction and High-performance Liquid Chromatography-diode Array Detection. Anal Bioanal Chem. 2010;397(6):2181-90. PubMed PMID: 20379813.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - A multi-residue method for pesticide residue analysis in rice grains using matrix solid-phase dispersion extraction and high-performance liquid chromatography-diode array detection. AU - Tsochatzis,Emmanouil D, AU - Menkissoglu-Spiroudi,Urania, AU - Karpouzas,Dimitrios G, AU - Tzimou-Tsitouridou,Roxani, Y1 - 2010/04/09/ PY - 2010/01/22/received PY - 2010/03/08/accepted PY - 2010/03/06/revised PY - 2010/4/10/entrez PY - 2010/4/10/pubmed PY - 2010/10/12/medline SP - 2181 EP - 90 JF - Analytical and bioanalytical chemistry JO - Anal Bioanal Chem VL - 397 IS - 6 N2 - Pesticides are widely used in rice cultivation, often resulting in detection of their residues in rice grains. So far, no analytical method has been available for the simultaneous determination of most rice pesticides in rice grains. This paper reports the development and validation of such a method for the determination of eight rice pesticides (penoxsulam tricyclazole, propanil, azoxystrobin, molinate, profoxydim, cyhalofop-butyl, deltamethrin) and 3,4-dichloroaniline, the main metabolite of propanil. Pesticide extraction and clean-up was performed by an optimized matrix solid-phase dispersion (MSPD) protocol on neutral alumina (5 g) using acetonitrile as the elution solvent. Samples were analyzed in a high-performance liquid chromatography-diode array detection (HPLC-DAD) system. Pesticide separation was achieved with a mobile phase of acetonitrile/water in a linear elution gradient from 30:70% (v/v) to 100:0% (v/v) in 14 min at a flow rate of 0.8 mL min(-1). Method validation was performed by means of linearity, intra-day accuracy, inter-day precision and sensitivity. Linear regression coefficients (R(2)) were always above 0.9948. Limits of detection (LOD) and quantification (LOQ) varied from 0.002 to 0.200 mg kg(-1) and 0.006 to 0.600 mg kg(-1), respectively. Recoveries were investigated at three fortification levels and were found to be acceptable (74-127%) with relative standard deviations (RSD) below 12%. Application of the method for the analysis of five commercial rice grain samples showed that the pesticide levels were below the LOD. Overall, the method developed is suitable for the determination of residues of most rice pesticides in rice grains at levels below the established MRLs. SN - 1618-2650 UR - https://www.unboundmedicine.com/medline/citation/20379813/A_multi_residue_method_for_pesticide_residue_analysis_in_rice_grains_using_matrix_solid_phase_dispersion_extraction_and_high_performance_liquid_chromatography_diode_array_detection_ DB - PRIME DP - Unbound Medicine ER -