Tags

Type your tag names separated by a space and hit enter

Comparison of tape stripping with the human skin blanching assay for the bioequivalence assessment of topical clobetasol propionate formulations.
J Pharm Pharm Sci. 2010; 13(1):11-20.JP

Abstract

PURPOSE

A draft guidance on tape stripping for assessing the bioavailability/bioequivalence of topical formulations was issued by the United States Food and Drug Administration in 1998 but has since been withdrawn. This was due to problems associated with the method and also inconsistencies and variability in the resulting data. The purpose of this study was to re-visit the tape stripping technique, incorporate refinements to reduce variability and validate the method using bioequivalence data obtained from the assessment of a topical corticosteroid cream containing 0.05% clobetasol propionate using the human skin-blanching assay.

METHODS

A pilot tape stripping study was conducted to establish the variability of the formulations.The bioequivalence of two different commercially available clobetasol propionate cream formulations and a clobetasol propionate ointment formulation were subsequently investigated using the tape stripping method.

RESULTS

The data from the pilot tape stripping study correlated well with data from the human skin-blanching assay. A subsequent pivotal tape stripping study confirmed bioequivalence between the two cream formulations whereas bio-inequivalence was demonstrated between the cream and ointment formulations.

CONCLUSIONS

These studies show that the results from tape stripping concur with data from the human skin blanching assay and demonstrate the potential of a well-controlled tape stripping study as an option for the assessment of bioequivalence of topical corticosteroid formulations.

Authors+Show Affiliations

Division of Pharmaceutics, Faculty of Pharmacy, Rhodes University, Grahamstown, South Africa.No affiliation info availableNo affiliation info available

Pub Type(s)

Comparative Study
Journal Article
Randomized Controlled Trial
Validation Study

Language

eng

PubMed ID

20456826

Citation

Au, Wai Ling, et al. "Comparison of Tape Stripping With the Human Skin Blanching Assay for the Bioequivalence Assessment of Topical Clobetasol Propionate Formulations." Journal of Pharmacy & Pharmaceutical Sciences : a Publication of the Canadian Society for Pharmaceutical Sciences, Societe Canadienne Des Sciences Pharmaceutiques, vol. 13, no. 1, 2010, pp. 11-20.
Au WL, Skinner M, Kanfer I. Comparison of tape stripping with the human skin blanching assay for the bioequivalence assessment of topical clobetasol propionate formulations. J Pharm Pharm Sci. 2010;13(1):11-20.
Au, W. L., Skinner, M., & Kanfer, I. (2010). Comparison of tape stripping with the human skin blanching assay for the bioequivalence assessment of topical clobetasol propionate formulations. Journal of Pharmacy & Pharmaceutical Sciences : a Publication of the Canadian Society for Pharmaceutical Sciences, Societe Canadienne Des Sciences Pharmaceutiques, 13(1), 11-20.
Au WL, Skinner M, Kanfer I. Comparison of Tape Stripping With the Human Skin Blanching Assay for the Bioequivalence Assessment of Topical Clobetasol Propionate Formulations. J Pharm Pharm Sci. 2010;13(1):11-20. PubMed PMID: 20456826.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Comparison of tape stripping with the human skin blanching assay for the bioequivalence assessment of topical clobetasol propionate formulations. AU - Au,Wai Ling, AU - Skinner,Michael, AU - Kanfer,Isadore, PY - 2010/5/12/entrez PY - 2010/5/12/pubmed PY - 2010/8/11/medline SP - 11 EP - 20 JF - Journal of pharmacy & pharmaceutical sciences : a publication of the Canadian Society for Pharmaceutical Sciences, Societe canadienne des sciences pharmaceutiques JO - J Pharm Pharm Sci VL - 13 IS - 1 N2 - PURPOSE: A draft guidance on tape stripping for assessing the bioavailability/bioequivalence of topical formulations was issued by the United States Food and Drug Administration in 1998 but has since been withdrawn. This was due to problems associated with the method and also inconsistencies and variability in the resulting data. The purpose of this study was to re-visit the tape stripping technique, incorporate refinements to reduce variability and validate the method using bioequivalence data obtained from the assessment of a topical corticosteroid cream containing 0.05% clobetasol propionate using the human skin-blanching assay. METHODS: A pilot tape stripping study was conducted to establish the variability of the formulations.The bioequivalence of two different commercially available clobetasol propionate cream formulations and a clobetasol propionate ointment formulation were subsequently investigated using the tape stripping method. RESULTS: The data from the pilot tape stripping study correlated well with data from the human skin-blanching assay. A subsequent pivotal tape stripping study confirmed bioequivalence between the two cream formulations whereas bio-inequivalence was demonstrated between the cream and ointment formulations. CONCLUSIONS: These studies show that the results from tape stripping concur with data from the human skin blanching assay and demonstrate the potential of a well-controlled tape stripping study as an option for the assessment of bioequivalence of topical corticosteroid formulations. SN - 1482-1826 UR - https://www.unboundmedicine.com/medline/citation/20456826/Comparison_of_tape_stripping_with_the_human_skin_blanching_assay_for_the_bioequivalence_assessment_of_topical_clobetasol_propionate_formulations_ L2 - http://ejournals.library.ualberta.ca/index.php/JPPS/article/viewFile/6804/6126 DB - PRIME DP - Unbound Medicine ER -