Citation
She, Yong-Xin, et al. "Class-specific Molecularly Imprinted Polymers for the Selective Extraction and Determination of Sulfonylurea Herbicides in Maize Samples By High-performance Liquid Chromatography-tandem Mass Spectrometry." Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences, vol. 878, no. 23, 2010, pp. 2047-53.
She YX, Cao WQ, Shi XM, et al. Class-specific molecularly imprinted polymers for the selective extraction and determination of sulfonylurea herbicides in maize samples by high-performance liquid chromatography-tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci. 2010;878(23):2047-53.
She, Y. X., Cao, W. Q., Shi, X. M., Lv, X. L., Liu, J. J., Wang, R. Y., Jin, F., Wang, J., & Xiao, H. (2010). Class-specific molecularly imprinted polymers for the selective extraction and determination of sulfonylurea herbicides in maize samples by high-performance liquid chromatography-tandem mass spectrometry. Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences, 878(23), 2047-53. https://doi.org/10.1016/j.jchromb.2010.05.038
She YX, et al. Class-specific Molecularly Imprinted Polymers for the Selective Extraction and Determination of Sulfonylurea Herbicides in Maize Samples By High-performance Liquid Chromatography-tandem Mass Spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci. 2010 Aug 1;878(23):2047-53. PubMed PMID: 20598653.
TY - JOUR
T1 - Class-specific molecularly imprinted polymers for the selective extraction and determination of sulfonylurea herbicides in maize samples by high-performance liquid chromatography-tandem mass spectrometry.
AU - She,Yong-Xin,
AU - Cao,Wei-Qiang,
AU - Shi,Xiao-Mei,
AU - Lv,Xiao-Ling,
AU - Liu,Jia-Jia,
AU - Wang,Rong-Yan,
AU - Jin,Fen,
AU - Wang,Jing,
AU - Xiao,Hang,
Y1 - 2010/05/31/
PY - 2010/02/19/received
PY - 2010/05/08/revised
PY - 2010/05/23/accepted
PY - 2010/7/6/entrez
PY - 2010/7/6/pubmed
PY - 2010/10/28/medline
SP - 2047
EP - 53
JF - Journal of chromatography. B, Analytical technologies in the biomedical and life sciences
JO - J Chromatogr B Analyt Technol Biomed Life Sci
VL - 878
IS - 23
N2 - A novel method based on the molecularly imprinted solid-phase extraction (MISPE) procedure has been developed for the simultaneous determination of concentrations of sulfonylurea herbicides such as chlorsulfuron (CS), monosulfuron (MNS), and thifensulfuron methyl (TFM) in maize samples by liquid chromatography-tandem quadrupole mass spectrometry (LC-MS/MS). The molecularly imprinted polymer (MIP) for sulfonylurea herbicides was synthesized by precipitation polymerization using chlorsulfuron as the template molecule, 2-(diethylamino)ethyl methacrylate (DEAMA) as the functional monomer, and trimethylolpropane trimethacrylate (TRIM) as the cross-linker. The selectivities of the chlorsulfuron template and its analogs on the molecularly imprinted polymer were evaluated by high-performance liquid chromatography (HPLC). The extraction and purification procedures for the solid-phase extraction (SPE) cartridge with a molecularly imprinted polymer as the adsorbent for the selected sulfonylurea herbicides were then established. A molecularly imprinted solid-phase extraction method followed by high-performance liquid chromatography-tandem mass spectrometry for the determination of chlorsulfuron, monosulfuron, and thifensulfuron methyl was also established. The mean recoveries of these compounds in maize were in the range 75-110% and the limits of detection (LOD) of chlorsulfuron, monosulfuron, and thifensulfuron methyl were 0.02, 0.75, and 1.45 microg kg(-1), respectively. It was demonstrated that the MISPE-HPLC-MS/MS method could be applied to the determination of chlorsulfuron, monosulfuron, and thifensulfuron methyl in maize samples.
SN - 1873-376X
UR - https://www.unboundmedicine.com/medline/citation/20598653/Class_specific_molecularly_imprinted_polymers_for_the_selective_extraction_and_determination_of_sulfonylurea_herbicides_in_maize_samples_by_high_performance_liquid_chromatography_tandem_mass_spectrometry_
L2 - https://linkinghub.elsevier.com/retrieve/pii/S1570-0232(10)00359-4
DB - PRIME
DP - Unbound Medicine
ER -