Tags

Type your tag names separated by a space and hit enter

Ultra-performance liquid chromatography mass spectrometry and sensitive bioassay methods for quantification of posaconazole plasma concentrations after oral dosing.
Antimicrob Agents Chemother. 2010 Dec; 54(12):5074-81.AA

Abstract

Posaconazole (POS) is a new antifungal agent for prevention and therapy of mycoses in immunocompromised patients. Variable POS pharmacokinetics after oral dosing may influence efficacy: a trough threshold of 0.5 μg/ml has been recently proposed. Measurement of POS plasma concentrations by complex chromatographic techniques may thus contribute to optimize prevention and management of life-threatening infections. No microbiological analytical method is available. The objective of this study was to develop and validate a new simplified ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method and a sensitive bioassay for quantification of POS over the clinical plasma concentration range. The UPLC-MS/MS equipment consisted of a triple quadrupole mass spectrometer, an electrospray ionization (ESI) source, and a C(18) analytical column. The Candida albicans POS-hypersusceptible mutant (MIC of 0.002 μg/ml) Δcdr1 Δcdr2 Δflu Δmdr1 Δcan constructed by targeted deletion of multidrug efflux transporters and calcineurin genes was used for the bioassay. POS was extracted from plasma by protein precipitation with acetonitrile-methanol (75%/25%, vol/vol). Reproducible standard curves were obtained over the range 0.014 to 12 (UPLC-MS/MS) and 0.028 to 12 μg/ml (bioassay). Intra- and interrun accuracy levels were 106% ± 2% and 103% ± 4% for UPLC-MS/MS and 102% ± 8% and 104% ± 1% for bioassay, respectively. The intra- and interrun coefficients of variation were 7% ± 4% and 7% ± 3% for UPLC-MS/MS and 5% ± 3% and 4% ± 2% for bioassay, respectively. An excellent correlation between POS plasma concentrations measured by UPLC-MS/MS and bioassay was found (concordance, 0.96). In 26 hemato-oncological patients receiving oral POS, 27/69 (39%) trough plasma concentrations were lower than 0.5 μg/ml. The UPLC-MS/MS method and sensitive bioassay offer alternative tools for accurate and precise quantification of the plasma concentrations in patients receiving oral posaconazole.

Authors+Show Affiliations

Quantitative Mass Spectrometry Facility, Faculty of Biology and Medicine, Centre Hospitalier Universitaire Vaudois, Rue du Bugnon 46, CH-1011 Lausanne, Switzerland. bertrand.rochat@chuv.chNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

20921320

Citation

Rochat, Bertrand, et al. "Ultra-performance Liquid Chromatography Mass Spectrometry and Sensitive Bioassay Methods for Quantification of Posaconazole Plasma Concentrations After Oral Dosing." Antimicrobial Agents and Chemotherapy, vol. 54, no. 12, 2010, pp. 5074-81.
Rochat B, Pascual A, Pesse B, et al. Ultra-performance liquid chromatography mass spectrometry and sensitive bioassay methods for quantification of posaconazole plasma concentrations after oral dosing. Antimicrob Agents Chemother. 2010;54(12):5074-81.
Rochat, B., Pascual, A., Pesse, B., Lamoth, F., Sanglard, D., Decosterd, L. A., Bille, J., & Marchetti, O. (2010). Ultra-performance liquid chromatography mass spectrometry and sensitive bioassay methods for quantification of posaconazole plasma concentrations after oral dosing. Antimicrobial Agents and Chemotherapy, 54(12), 5074-81. https://doi.org/10.1128/AAC.00022-10
Rochat B, et al. Ultra-performance Liquid Chromatography Mass Spectrometry and Sensitive Bioassay Methods for Quantification of Posaconazole Plasma Concentrations After Oral Dosing. Antimicrob Agents Chemother. 2010;54(12):5074-81. PubMed PMID: 20921320.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Ultra-performance liquid chromatography mass spectrometry and sensitive bioassay methods for quantification of posaconazole plasma concentrations after oral dosing. AU - Rochat,Bertrand, AU - Pascual,Andres, AU - Pesse,Benoît, AU - Lamoth,Frédéric, AU - Sanglard,Dominique, AU - Decosterd,Laurent A, AU - Bille,Jacques, AU - Marchetti,Oscar, Y1 - 2010/10/04/ PY - 2010/10/6/entrez PY - 2010/10/6/pubmed PY - 2011/3/12/medline SP - 5074 EP - 81 JF - Antimicrobial agents and chemotherapy JO - Antimicrob Agents Chemother VL - 54 IS - 12 N2 - Posaconazole (POS) is a new antifungal agent for prevention and therapy of mycoses in immunocompromised patients. Variable POS pharmacokinetics after oral dosing may influence efficacy: a trough threshold of 0.5 μg/ml has been recently proposed. Measurement of POS plasma concentrations by complex chromatographic techniques may thus contribute to optimize prevention and management of life-threatening infections. No microbiological analytical method is available. The objective of this study was to develop and validate a new simplified ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) method and a sensitive bioassay for quantification of POS over the clinical plasma concentration range. The UPLC-MS/MS equipment consisted of a triple quadrupole mass spectrometer, an electrospray ionization (ESI) source, and a C(18) analytical column. The Candida albicans POS-hypersusceptible mutant (MIC of 0.002 μg/ml) Δcdr1 Δcdr2 Δflu Δmdr1 Δcan constructed by targeted deletion of multidrug efflux transporters and calcineurin genes was used for the bioassay. POS was extracted from plasma by protein precipitation with acetonitrile-methanol (75%/25%, vol/vol). Reproducible standard curves were obtained over the range 0.014 to 12 (UPLC-MS/MS) and 0.028 to 12 μg/ml (bioassay). Intra- and interrun accuracy levels were 106% ± 2% and 103% ± 4% for UPLC-MS/MS and 102% ± 8% and 104% ± 1% for bioassay, respectively. The intra- and interrun coefficients of variation were 7% ± 4% and 7% ± 3% for UPLC-MS/MS and 5% ± 3% and 4% ± 2% for bioassay, respectively. An excellent correlation between POS plasma concentrations measured by UPLC-MS/MS and bioassay was found (concordance, 0.96). In 26 hemato-oncological patients receiving oral POS, 27/69 (39%) trough plasma concentrations were lower than 0.5 μg/ml. The UPLC-MS/MS method and sensitive bioassay offer alternative tools for accurate and precise quantification of the plasma concentrations in patients receiving oral posaconazole. SN - 1098-6596 UR - https://www.unboundmedicine.com/medline/citation/20921320/Ultra_performance_liquid_chromatography_mass_spectrometry_and_sensitive_bioassay_methods_for_quantification_of_posaconazole_plasma_concentrations_after_oral_dosing_ L2 - https://journals.asm.org/doi/10.1128/AAC.00022-10?url_ver=Z39.88-2003&rfr_id=ori:rid:crossref.org&rfr_dat=cr_pub=pubmed DB - PRIME DP - Unbound Medicine ER -