Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images.
Med Phys. 2010 Oct; 37(10):5395-406.MP

Abstract

PURPOSE

Applications of cone-beam CT (CBCT) to image-guided radiationtherapy (IGRT) are hampered by shading artifacts in the reconstructed images. These artifacts are mainly due to scatter contamination in the projections but also can result from uncorrected beam hardening effects as well as nonlinearities in responses of the amorphous silicon flat panel detectors. While currently, CBCT is mainly used to provide patient geometry information for treatment setup, more demanding applications requiring high-quality CBCT images are under investigation. To tackle these challenges, many CBCT correction algorithms have been proposed; yet, a standard approach still remains unclear. In this work, we propose a shading correction method for CBCT that addresses artifacts from low-frequency projection errors. The method is consistent with the current workflow of radiation therapy.

METHODS

With much smaller inherent scatter signals and more accurate detectors, diagnostic multidetector CT (MDCT) provides high quality CT images that are routinely used for radiation treatment planning. Using the MDCT image as "free" prior information, we first estimate the primary projections in the CBCT scan via forward projection of the spatially registered MDCT data. Since most of the CBCT shading artifacts stem from low-frequency errors in the projections such as scatter, these errors can be accurately estimated by low-pass filtering the difference between the estimated and raw CBCT projections. The error estimates are then subtracted from the raw CBCT projections. Our method is distinct from other published correction methods that use the MDCT image as a prior because it is projection-based and uses limited patient anatomical information from the MDCT image. The merit of CBCT-based treatment monitoring is therefore retained.

RESULTS

The proposed method is evaluated using two phantom studies on tabletop systems. On the Catphan 600 phantom, our approach reduces the reconstruction error from 348 Hounsfield unit (HU) without correction to 4 HU around the object center after correction, and from 375 HU to 17 HU in the high-contrast regions. In the selected regions of interest (ROIs), the average image contrast is increased by a factor of 3.3. When noise suppression is implemented, the proposed correction substantially improves the contrast-to-noise ratio (CNR) and therefore the visibility of low-contrast objects, as seen in a more challenging pelvis phantom study. Besides a significant improvement in image uniformity, a low-contrast object of approximately 25 HU, which is otherwise buried in the shading artifacts, can be clearly identified after the proposed correction due to a CNR increase of 3.1. Compared to a kernel-based scatter correction method coupled with an analytical beam hardening correction, our approach also shows an overall improved performance with some residual artifacts.

CONCLUSIONS

By providing effective shading correction, our approach has the potential to improve the accuracy of more advanced CBCT-based clinical applications for IGRT, such as tumor delineation and dose calculation.

Authors+Show Affiliations

Nuclear and Radiological Engineering and Medical Physics Programs, The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332, USA.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

21089775

Citation

Niu, Tianye, et al. "Shading Correction for On-board Cone-beam CT in Radiation Therapy Using Planning MDCT Images." Medical Physics, vol. 37, no. 10, 2010, pp. 5395-406.
Niu T, Sun M, Star-Lack J, et al. Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images. Med Phys. 2010;37(10):5395-406.
Niu, T., Sun, M., Star-Lack, J., Gao, H., Fan, Q., & Zhu, L. (2010). Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images. Medical Physics, 37(10), 5395-406.
Niu T, et al. Shading Correction for On-board Cone-beam CT in Radiation Therapy Using Planning MDCT Images. Med Phys. 2010;37(10):5395-406. PubMed PMID: 21089775.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Shading correction for on-board cone-beam CT in radiation therapy using planning MDCT images. AU - Niu,Tianye, AU - Sun,Mingshan, AU - Star-Lack,Josh, AU - Gao,Hewei, AU - Fan,Qiyong, AU - Zhu,Lei, PY - 2010/11/25/entrez PY - 2010/11/26/pubmed PY - 2010/12/16/medline SP - 5395 EP - 406 JF - Medical physics JO - Med Phys VL - 37 IS - 10 N2 - PURPOSE: Applications of cone-beam CT (CBCT) to image-guided radiationtherapy (IGRT) are hampered by shading artifacts in the reconstructed images. These artifacts are mainly due to scatter contamination in the projections but also can result from uncorrected beam hardening effects as well as nonlinearities in responses of the amorphous silicon flat panel detectors. While currently, CBCT is mainly used to provide patient geometry information for treatment setup, more demanding applications requiring high-quality CBCT images are under investigation. To tackle these challenges, many CBCT correction algorithms have been proposed; yet, a standard approach still remains unclear. In this work, we propose a shading correction method for CBCT that addresses artifacts from low-frequency projection errors. The method is consistent with the current workflow of radiation therapy. METHODS: With much smaller inherent scatter signals and more accurate detectors, diagnostic multidetector CT (MDCT) provides high quality CT images that are routinely used for radiation treatment planning. Using the MDCT image as "free" prior information, we first estimate the primary projections in the CBCT scan via forward projection of the spatially registered MDCT data. Since most of the CBCT shading artifacts stem from low-frequency errors in the projections such as scatter, these errors can be accurately estimated by low-pass filtering the difference between the estimated and raw CBCT projections. The error estimates are then subtracted from the raw CBCT projections. Our method is distinct from other published correction methods that use the MDCT image as a prior because it is projection-based and uses limited patient anatomical information from the MDCT image. The merit of CBCT-based treatment monitoring is therefore retained. RESULTS: The proposed method is evaluated using two phantom studies on tabletop systems. On the Catphan 600 phantom, our approach reduces the reconstruction error from 348 Hounsfield unit (HU) without correction to 4 HU around the object center after correction, and from 375 HU to 17 HU in the high-contrast regions. In the selected regions of interest (ROIs), the average image contrast is increased by a factor of 3.3. When noise suppression is implemented, the proposed correction substantially improves the contrast-to-noise ratio (CNR) and therefore the visibility of low-contrast objects, as seen in a more challenging pelvis phantom study. Besides a significant improvement in image uniformity, a low-contrast object of approximately 25 HU, which is otherwise buried in the shading artifacts, can be clearly identified after the proposed correction due to a CNR increase of 3.1. Compared to a kernel-based scatter correction method coupled with an analytical beam hardening correction, our approach also shows an overall improved performance with some residual artifacts. CONCLUSIONS: By providing effective shading correction, our approach has the potential to improve the accuracy of more advanced CBCT-based clinical applications for IGRT, such as tumor delineation and dose calculation. SN - 0094-2405 UR - https://www.unboundmedicine.com/medline/citation/21089775/Shading_correction_for_on_board_cone_beam_CT_in_radiation_therapy_using_planning_MDCT_images_ L2 - https://doi.org/10.1118/1.3483260 DB - PRIME DP - Unbound Medicine ER -