Ionic liquid-functionalized graphene as modifier for electrochemical and electrocatalytic improvement: comparison of different carbon electrodes.Anal Chim Acta. 2011 Apr 01; 690(2):169-74.AC
Abstract
Electrochemical activities of typically electrochemical targets at three kinds of modified carbon electrodes, i.e. carbon ionic liquid electrode (CILE), graphene/carbon paste electrode (CPE), and ionic liquid-functionalized graphene (IL-graphene)/CPE, were compared in detail. The redox processes of the probes at IL-graphene/CPE were faster than those at CILE and graphene/CPE from cyclic voltammetry. An electrochemical method for the simultaneous determination of guanine and adenine was described with detection limits of 6.5×10(-8) mol L(-1) (guanine) and 3.2×10(-8) mol L(-1) (adenine). Single A→G mutation of sequence-specific DNA could be discriminated by the IL-graphene/CPE.
Links
MeSH
Pub Type(s)
Comparative Study
Journal Article
Research Support, Non-U.S. Gov't
Language
eng
PubMed ID
21435472
Citation
Du, Meng, et al. "Ionic Liquid-functionalized Graphene as Modifier for Electrochemical and Electrocatalytic Improvement: Comparison of Different Carbon Electrodes." Analytica Chimica Acta, vol. 690, no. 2, 2011, pp. 169-74.
Du M, Yang T, Ma S, et al. Ionic liquid-functionalized graphene as modifier for electrochemical and electrocatalytic improvement: comparison of different carbon electrodes. Anal Chim Acta. 2011;690(2):169-74.
Du, M., Yang, T., Ma, S., Zhao, C., & Jiao, K. (2011). Ionic liquid-functionalized graphene as modifier for electrochemical and electrocatalytic improvement: comparison of different carbon electrodes. Analytica Chimica Acta, 690(2), 169-74. https://doi.org/10.1016/j.aca.2011.01.051
Du M, et al. Ionic Liquid-functionalized Graphene as Modifier for Electrochemical and Electrocatalytic Improvement: Comparison of Different Carbon Electrodes. Anal Chim Acta. 2011 Apr 1;690(2):169-74. PubMed PMID: 21435472.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR
T1 - Ionic liquid-functionalized graphene as modifier for electrochemical and electrocatalytic improvement: comparison of different carbon electrodes.
AU - Du,Meng,
AU - Yang,Tao,
AU - Ma,Suyan,
AU - Zhao,Changzhi,
AU - Jiao,Kui,
Y1 - 2011/02/18/
PY - 2010/12/07/received
PY - 2011/01/22/revised
PY - 2011/01/26/accepted
PY - 2011/3/26/entrez
PY - 2011/3/26/pubmed
PY - 2011/7/8/medline
SP - 169
EP - 74
JF - Analytica chimica acta
JO - Anal Chim Acta
VL - 690
IS - 2
N2 - Electrochemical activities of typically electrochemical targets at three kinds of modified carbon electrodes, i.e. carbon ionic liquid electrode (CILE), graphene/carbon paste electrode (CPE), and ionic liquid-functionalized graphene (IL-graphene)/CPE, were compared in detail. The redox processes of the probes at IL-graphene/CPE were faster than those at CILE and graphene/CPE from cyclic voltammetry. An electrochemical method for the simultaneous determination of guanine and adenine was described with detection limits of 6.5×10(-8) mol L(-1) (guanine) and 3.2×10(-8) mol L(-1) (adenine). Single A→G mutation of sequence-specific DNA could be discriminated by the IL-graphene/CPE.
SN - 1873-4324
UR - https://www.unboundmedicine.com/medline/citation/21435472/Ionic_liquid_functionalized_graphene_as_modifier_for_electrochemical_and_electrocatalytic_improvement:_comparison_of_different_carbon_electrodes_
L2 - https://linkinghub.elsevier.com/retrieve/pii/S0003-2670(11)00163-2
DB - PRIME
DP - Unbound Medicine
ER -