Tags

Type your tag names separated by a space and hit enter

Validation of a new method for finding the rotational axes of the knee using both marker-based roentgen stereophotogrammetric analysis and 3D video-based motion analysis for kinematic measurements.
J Biomech Eng. 2011 May; 133(5):051003.JB

Abstract

In a previous paper, we reported the virtual axis finder, which is a new method for finding the rotational axes of the knee. The virtual axis finder was validated through simulations that were subject to limitations. Hence, the objective of the present study was to perform a mechanical validation with two measurement modalities: 3D video-based motion analysis and marker-based roentgen stereophotogrammetric analysis (RSA). A two rotational axis mechanism was developed, which simulated internal-external (or longitudinal) and flexion-extension (FE) rotations. The actual axes of rotation were known with respect to motion analysis and RSA markers within ± 0.0006 deg and ± 0.036 mm and ± 0.0001 deg and ± 0.016 mm, respectively. The orientation and position root mean squared errors for identifying the longitudinal rotation (LR) and FE axes with video-based motion analysis (0.26 deg, 0.28 m, 0.36 deg, and 0.25 mm, respectively) were smaller than with RSA (1.04 deg, 0.84 mm, 0.82 deg, and 0.32 mm, respectively). The random error or precision in the orientation and position was significantly better (p=0.01 and p=0.02, respectively) in identifying the LR axis with video-based motion analysis (0.23 deg and 0.24 mm) than with RSA (0.95 deg and 0.76 mm). There was no significant difference in the bias errors between measurement modalities. In comparing the mechanical validations to virtual validations, the virtual validations produced comparable errors to those of the mechanical validation. The only significant difference between the errors of the mechanical and virtual validations was the precision in the position of the LR axis while simulating video-based motion analysis (0.24 mm and 0.78 mm, p=0.019). These results indicate that video-based motion analysis with the equipment used in this study is the superior measurement modality for use with the virtual axis finder but both measurement modalities produce satisfactory results. The lack of significant differences between validation techniques suggests that the virtual sensitivity analysis previously performed was appropriately modeled. Thus, the virtual axis finder can be applied with a thorough understanding of its errors in a variety of test conditions.

Authors+Show Affiliations

Department of Biomedical Engineering, University of California, One Shields Avenue, Davis, CA 95616, USA..No affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Validation Study

Language

eng

PubMed ID

21599094

Citation

Roland, Michelle, et al. "Validation of a New Method for Finding the Rotational Axes of the Knee Using Both Marker-based Roentgen Stereophotogrammetric Analysis and 3D Video-based Motion Analysis for Kinematic Measurements." Journal of Biomechanical Engineering, vol. 133, no. 5, 2011, p. 051003.
Roland M, Hull ML, Howell SM. Validation of a new method for finding the rotational axes of the knee using both marker-based roentgen stereophotogrammetric analysis and 3D video-based motion analysis for kinematic measurements. J Biomech Eng. 2011;133(5):051003.
Roland, M., Hull, M. L., & Howell, S. M. (2011). Validation of a new method for finding the rotational axes of the knee using both marker-based roentgen stereophotogrammetric analysis and 3D video-based motion analysis for kinematic measurements. Journal of Biomechanical Engineering, 133(5), 051003. https://doi.org/10.1115/1.4003437
Roland M, Hull ML, Howell SM. Validation of a New Method for Finding the Rotational Axes of the Knee Using Both Marker-based Roentgen Stereophotogrammetric Analysis and 3D Video-based Motion Analysis for Kinematic Measurements. J Biomech Eng. 2011;133(5):051003. PubMed PMID: 21599094.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Validation of a new method for finding the rotational axes of the knee using both marker-based roentgen stereophotogrammetric analysis and 3D video-based motion analysis for kinematic measurements. AU - Roland,Michelle, AU - Hull,M L, AU - Howell,S M, PY - 2011/5/24/entrez PY - 2011/5/24/pubmed PY - 2011/9/8/medline SP - 051003 EP - 051003 JF - Journal of biomechanical engineering JO - J Biomech Eng VL - 133 IS - 5 N2 - In a previous paper, we reported the virtual axis finder, which is a new method for finding the rotational axes of the knee. The virtual axis finder was validated through simulations that were subject to limitations. Hence, the objective of the present study was to perform a mechanical validation with two measurement modalities: 3D video-based motion analysis and marker-based roentgen stereophotogrammetric analysis (RSA). A two rotational axis mechanism was developed, which simulated internal-external (or longitudinal) and flexion-extension (FE) rotations. The actual axes of rotation were known with respect to motion analysis and RSA markers within ± 0.0006 deg and ± 0.036 mm and ± 0.0001 deg and ± 0.016 mm, respectively. The orientation and position root mean squared errors for identifying the longitudinal rotation (LR) and FE axes with video-based motion analysis (0.26 deg, 0.28 m, 0.36 deg, and 0.25 mm, respectively) were smaller than with RSA (1.04 deg, 0.84 mm, 0.82 deg, and 0.32 mm, respectively). The random error or precision in the orientation and position was significantly better (p=0.01 and p=0.02, respectively) in identifying the LR axis with video-based motion analysis (0.23 deg and 0.24 mm) than with RSA (0.95 deg and 0.76 mm). There was no significant difference in the bias errors between measurement modalities. In comparing the mechanical validations to virtual validations, the virtual validations produced comparable errors to those of the mechanical validation. The only significant difference between the errors of the mechanical and virtual validations was the precision in the position of the LR axis while simulating video-based motion analysis (0.24 mm and 0.78 mm, p=0.019). These results indicate that video-based motion analysis with the equipment used in this study is the superior measurement modality for use with the virtual axis finder but both measurement modalities produce satisfactory results. The lack of significant differences between validation techniques suggests that the virtual sensitivity analysis previously performed was appropriately modeled. Thus, the virtual axis finder can be applied with a thorough understanding of its errors in a variety of test conditions. SN - 1528-8951 UR - https://www.unboundmedicine.com/medline/citation/21599094/Validation_of_a_new_method_for_finding_the_rotational_axes_of_the_knee_using_both_marker_based_roentgen_stereophotogrammetric_analysis_and_3D_video_based_motion_analysis_for_kinematic_measurements_ L2 - https://asmedigitalcollection.asme.org/biomechanical/article-lookup/doi/10.1115/1.4003437 DB - PRIME DP - Unbound Medicine ER -