Tags

Type your tag names separated by a space and hit enter

Measurement of nicotine, cotinine and trans-3'-hydroxycotinine in meconium by liquid chromatography-tandem mass spectrometry.
J Chromatogr B Analyt Technol Biomed Life Sci. 2011 Jul 15; 879(22):2142-8.JC

Abstract

Nicotine (NIC), cotinine (COT) and trans-3'-hydroxycotinine (OHCOT) are the most prevalent and abundant tobacco biomarkers in meconium. We have developed and validated an accurate and precise method for the measurement of these analytes in meconium in which potassium hydroxide is used to digest the meconium sample, followed by solid phase extraction from the liquified sample. The precision of OHCOT, COT and NIC measurements (intra-day and inter-day) were 4.8-10.6%, 3.4-11.6% and 9.3-15.8%, respectively. Evaluation of accuracy indicated bias of -4.0, 2.0 and 0.8% for OHCOT at concentrations of 0.5, 2.5 and 7.5 ng/g. The accuracy estimates for COT at concentrations of 0.5, 2.5 and 7.5 ng/g are 4.0, 4.0 and 5.7%, respectively. For NIC at 2, 10 and 30 ng/g the accuracy was calculated to be 3.0, 5.0 and 5.1%, respectively. The linear range of standard solutions was 0.125-37.5 ng/mL for OHCOT and COT, and 0.75-150 ng/mL for NIC. This method was applied to the analysis of 374 meconium samples from infants of both smoking and nonsmoking mothers. Positive correlations with r(2)≥0.63 were observed between NIC and COT, COT and OHCOT, NIC and OHCOT, and NIC and (OHCOT+COT) in these samples.

Authors+Show Affiliations

Division of Laboratory Science, National Center for Environmental Health, Centers for Disease Control and Prevention, Atlanta, GA 30341, USA. yax1@cdc.govNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article

Language

eng

PubMed ID

21689995

Citation

Xia, Yang, et al. "Measurement of Nicotine, Cotinine and Trans-3'-hydroxycotinine in Meconium By Liquid Chromatography-tandem Mass Spectrometry." Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences, vol. 879, no. 22, 2011, pp. 2142-8.
Xia Y, Xu M, Alexander RR, et al. Measurement of nicotine, cotinine and trans-3'-hydroxycotinine in meconium by liquid chromatography-tandem mass spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci. 2011;879(22):2142-8.
Xia, Y., Xu, M., Alexander, R. R., & Bernert, J. T. (2011). Measurement of nicotine, cotinine and trans-3'-hydroxycotinine in meconium by liquid chromatography-tandem mass spectrometry. Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences, 879(22), 2142-8. https://doi.org/10.1016/j.jchromb.2011.05.054
Xia Y, et al. Measurement of Nicotine, Cotinine and Trans-3'-hydroxycotinine in Meconium By Liquid Chromatography-tandem Mass Spectrometry. J Chromatogr B Analyt Technol Biomed Life Sci. 2011 Jul 15;879(22):2142-8. PubMed PMID: 21689995.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Measurement of nicotine, cotinine and trans-3'-hydroxycotinine in meconium by liquid chromatography-tandem mass spectrometry. AU - Xia,Yang, AU - Xu,Meng, AU - Alexander,Ricky R, AU - Bernert,John T, Y1 - 2011/06/12/ PY - 2011/02/03/received PY - 2011/05/03/revised PY - 2011/05/28/accepted PY - 2011/6/22/entrez PY - 2011/6/22/pubmed PY - 2011/10/1/medline SP - 2142 EP - 8 JF - Journal of chromatography. B, Analytical technologies in the biomedical and life sciences JO - J Chromatogr B Analyt Technol Biomed Life Sci VL - 879 IS - 22 N2 - Nicotine (NIC), cotinine (COT) and trans-3'-hydroxycotinine (OHCOT) are the most prevalent and abundant tobacco biomarkers in meconium. We have developed and validated an accurate and precise method for the measurement of these analytes in meconium in which potassium hydroxide is used to digest the meconium sample, followed by solid phase extraction from the liquified sample. The precision of OHCOT, COT and NIC measurements (intra-day and inter-day) were 4.8-10.6%, 3.4-11.6% and 9.3-15.8%, respectively. Evaluation of accuracy indicated bias of -4.0, 2.0 and 0.8% for OHCOT at concentrations of 0.5, 2.5 and 7.5 ng/g. The accuracy estimates for COT at concentrations of 0.5, 2.5 and 7.5 ng/g are 4.0, 4.0 and 5.7%, respectively. For NIC at 2, 10 and 30 ng/g the accuracy was calculated to be 3.0, 5.0 and 5.1%, respectively. The linear range of standard solutions was 0.125-37.5 ng/mL for OHCOT and COT, and 0.75-150 ng/mL for NIC. This method was applied to the analysis of 374 meconium samples from infants of both smoking and nonsmoking mothers. Positive correlations with r(2)≥0.63 were observed between NIC and COT, COT and OHCOT, NIC and OHCOT, and NIC and (OHCOT+COT) in these samples. SN - 1873-376X UR - https://www.unboundmedicine.com/medline/citation/21689995/Measurement_of_nicotine_cotinine_and_trans_3'_hydroxycotinine_in_meconium_by_liquid_chromatography_tandem_mass_spectrometry_ L2 - https://linkinghub.elsevier.com/retrieve/pii/S1570-0232(11)00371-0 DB - PRIME DP - Unbound Medicine ER -