Application of a validated ultra performance liquid chromatography-tandem mass spectrometry method for the quantification of darunavir in human plasma for a bioequivalence study in Indian subjects.
J Chromatogr B Analyt Technol Biomed Life Sci. 2011 Aug 15; 879(24):2443-53.JC

Abstract

A simple, precise and rapid ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed and validated for the quantification of darunavir, a protease inhibitor, using darunavir-d9 as internal standard (IS). The method involved liquid-liquid extraction of darunavir and IS in methyl-tert-butyl ether from 50 μL human plasma. The chromatographic separation was achieved on an Acquity UPLC BEH C18 (50 mm × 2.1mm, 1.7 μm particle size) analytical column under gradient conditions, in a run time of 1.6 min. The precursor → product ion transitions for darunavir (m/z 548.1 → 392.0) and IS (m/z 557.1 → 401.0) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring (MRM) and positive ion mode. The method was extensively validated for its selectivity, sensitivity, carryover check, linearity, precision and accuracy, reinjection reproducibility, recovery, matrix effect, ion suppression/enhancement, stability and dilution integrity. The linearity of the method was established in the concentration range of 1.0-5000 ng/mL. The mean relative recovery for darunavir (100.8%) and IS (89.8%) from spiked plasma samples was consistent and reproducible. The application of this method for routine measurement of plasma darunavir concentration was demonstrated by a bioequivalence study conducted in 40 healthy Indian subjects for a 600 mg tablet formulation along with 100mg ritonavir as booster under fast and fed conditions. To demonstrate the reproducibility in the measurement of study data, an incurred sample reanalysis was done with 400 subject samples and the % change in concentration was within ± 12%.

Authors+Show Affiliations

Chemistry Department, Kadi Sarva Vishwavidyalaya, Sarva Vidyalaya Campus, Sector 15/23, Gandhinagar 382015, India.No affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Validation Study

Language

eng

PubMed ID

21788160

Citation

Gupta, Ajay, et al. "Application of a Validated Ultra Performance Liquid Chromatography-tandem Mass Spectrometry Method for the Quantification of Darunavir in Human Plasma for a Bioequivalence Study in Indian Subjects." Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences, vol. 879, no. 24, 2011, pp. 2443-53.
Gupta A, Singhal P, Shrivastav PS, et al. Application of a validated ultra performance liquid chromatography-tandem mass spectrometry method for the quantification of darunavir in human plasma for a bioequivalence study in Indian subjects. J Chromatogr B Analyt Technol Biomed Life Sci. 2011;879(24):2443-53.
Gupta, A., Singhal, P., Shrivastav, P. S., & Sanyal, M. (2011). Application of a validated ultra performance liquid chromatography-tandem mass spectrometry method for the quantification of darunavir in human plasma for a bioequivalence study in Indian subjects. Journal of Chromatography. B, Analytical Technologies in the Biomedical and Life Sciences, 879(24), 2443-53. https://doi.org/10.1016/j.jchromb.2011.07.008
Gupta A, et al. Application of a Validated Ultra Performance Liquid Chromatography-tandem Mass Spectrometry Method for the Quantification of Darunavir in Human Plasma for a Bioequivalence Study in Indian Subjects. J Chromatogr B Analyt Technol Biomed Life Sci. 2011 Aug 15;879(24):2443-53. PubMed PMID: 21788160.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Application of a validated ultra performance liquid chromatography-tandem mass spectrometry method for the quantification of darunavir in human plasma for a bioequivalence study in Indian subjects. AU - Gupta,Ajay, AU - Singhal,Puran, AU - Shrivastav,Pranav S, AU - Sanyal,Mallika, Y1 - 2011/07/18/ PY - 2011/04/23/received PY - 2011/07/03/revised PY - 2011/07/07/accepted PY - 2011/7/27/entrez PY - 2011/7/27/pubmed PY - 2011/10/22/medline SP - 2443 EP - 53 JF - Journal of chromatography. B, Analytical technologies in the biomedical and life sciences JO - J Chromatogr B Analyt Technol Biomed Life Sci VL - 879 IS - 24 N2 - A simple, precise and rapid ultra performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method has been developed and validated for the quantification of darunavir, a protease inhibitor, using darunavir-d9 as internal standard (IS). The method involved liquid-liquid extraction of darunavir and IS in methyl-tert-butyl ether from 50 μL human plasma. The chromatographic separation was achieved on an Acquity UPLC BEH C18 (50 mm × 2.1mm, 1.7 μm particle size) analytical column under gradient conditions, in a run time of 1.6 min. The precursor → product ion transitions for darunavir (m/z 548.1 → 392.0) and IS (m/z 557.1 → 401.0) were monitored on a triple quadrupole mass spectrometer, operating in the multiple reaction monitoring (MRM) and positive ion mode. The method was extensively validated for its selectivity, sensitivity, carryover check, linearity, precision and accuracy, reinjection reproducibility, recovery, matrix effect, ion suppression/enhancement, stability and dilution integrity. The linearity of the method was established in the concentration range of 1.0-5000 ng/mL. The mean relative recovery for darunavir (100.8%) and IS (89.8%) from spiked plasma samples was consistent and reproducible. The application of this method for routine measurement of plasma darunavir concentration was demonstrated by a bioequivalence study conducted in 40 healthy Indian subjects for a 600 mg tablet formulation along with 100mg ritonavir as booster under fast and fed conditions. To demonstrate the reproducibility in the measurement of study data, an incurred sample reanalysis was done with 400 subject samples and the % change in concentration was within ± 12%. SN - 1873-376X UR - https://www.unboundmedicine.com/medline/citation/21788160/Application_of_a_validated_ultra_performance_liquid_chromatography_tandem_mass_spectrometry_method_for_the_quantification_of_darunavir_in_human_plasma_for_a_bioequivalence_study_in_Indian_subjects_ L2 - https://linkinghub.elsevier.com/retrieve/pii/S1570-0232(11)00459-4 DB - PRIME DP - Unbound Medicine ER -