Citation
Xiang, Yi, et al. "Determination of Cyclobenzaprine in Human Plasma By Liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry and Its Application in a Pharmacokinetic Study." Biomedical Chromatography : BMC, vol. 26, no. 9, 2012, pp. 1083-8.
Xiang Y, Zhou L, Qian Z, et al. Determination of cyclobenzaprine in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry and its application in a pharmacokinetic study. Biomed Chromatogr. 2012;26(9):1083-8.
Xiang, Y., Zhou, L., Qian, Z., Peng, K., Li, D., Chen, X., Jiang, H., & Zheng, H. (2012). Determination of cyclobenzaprine in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry and its application in a pharmacokinetic study. Biomedical Chromatography : BMC, 26(9), 1083-8. https://doi.org/10.1002/bmc.1751
Xiang Y, et al. Determination of Cyclobenzaprine in Human Plasma By Liquid Chromatography-electrospray Ionization Tandem Mass Spectrometry and Its Application in a Pharmacokinetic Study. Biomed Chromatogr. 2012;26(9):1083-8. PubMed PMID: 22120786.
TY - JOUR
T1 - Determination of cyclobenzaprine in human plasma by liquid chromatography-electrospray ionization tandem mass spectrometry and its application in a pharmacokinetic study.
AU - Xiang,Yi,
AU - Zhou,Liping,
AU - Qian,Zhenyu,
AU - Peng,Kelong,
AU - Li,Dongyan,
AU - Chen,Xiaomei,
AU - Jiang,Hongliang,
AU - Zheng,Heng,
Y1 - 2011/11/25/
PY - 2011/08/10/received
PY - 2011/10/16/revised
PY - 2011/10/16/accepted
PY - 2011/11/29/entrez
PY - 2011/11/29/pubmed
PY - 2013/2/21/medline
SP - 1083
EP - 8
JF - Biomedical chromatography : BMC
JO - Biomed Chromatogr
VL - 26
IS - 9
N2 - A sensitive, rapid and simple liquid chromatography-electrospray ionization mass spectrometry (LC-ESI-MS/MS) method was developed for the quantitative determination of cyclobenzaprine in human plasma, to study the pharmacokinetic behavior of cyclobenzaprine capsule in healthy Chinese volunteers. With escitalopram as the internal standard (IS), sample pretreatment involved a one-step liquid-liquid extraction using saturated sodium carbonate solution and hexane-diethyl ether (3:1, v/v). The separation was performed on an Ultimate XB-CN column (150 × 2.1 mm, 5 µm). Isocratic elution was applied using acetonitrile-water (40:60, v/v) containing 10 m M ammonium acetate and 0.1% formic acid. The detection was carried out on a triple-quadrupole tandem mass spectrometer in multiple reaction monitoring mode via electrospray ionization. The ion-pairs including m/z 276.2-216.2 for cyclobenzaprine and m/z 325.2-109.1 for IS were used for monitoring. Linear calibration curves were obtained over the range of 0.049-29.81 ng/mL with the lower limit of quantification at 0.049 ng/mL. The intra- and inter-day precision showed ≤ 6.5% relative standard deviation. The established method laid the groundwork for follow-up studies and provided basis for the clinical administration of cyclobenzaprine.
SN - 1099-0801
UR - https://www.unboundmedicine.com/medline/citation/22120786/Determination_of_cyclobenzaprine_in_human_plasma_by_liquid_chromatography_electrospray_ionization_tandem_mass_spectrometry_and_its_application_in_a_pharmacokinetic_study_
L2 - https://doi.org/10.1002/bmc.1751
DB - PRIME
DP - Unbound Medicine
ER -