Liquid chromatography-tandem mass spectrometry method for the quantification of mycophenolic acid and its phenolic glucuronide in saliva and plasma using a standardized saliva collection device.
J Chromatogr A. 2012 Jun 08; 1241:52-9.JC

Abstract

A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for simultaneous quantification of mycophenolic acid (MPA) and its phenolic glucuronide (MPAG) in saliva and plasma. Saliva was collected and processed using a standardized commercially available collection device. Sample preparation comprised of protein precipitation with acetonitrile and subsequent centrifugation, followed by evaporation and reconstitution with mobile phase. A labeled isotope of MPA was used as internal standard, and chromatographic separation was achieved on a C18 column with an isocratic flow. LC-MS/MS detection was performed using a triple-stage quadrupole mass spectrometer working in selected reaction monitoring mode with positive electrospray ionization (ESI). The analytes were quantified in a single run within 2 min. For saliva, linearity was demonstrated over the concentration range of 5.0 to 400.0 ng/ml for both MPA and MPAG, and from 0.08 to 20.00 μg/ml for MPA and 0.4 to 100.0 μg/ml for MPAG in plasma. The lower limits of quantification for MPA and MPAG were 0.07 and 0.80 ng/ml in saliva, and 0.002 and 0.009 μg/ml in plasma, respectively. Inter- and intra-day precisions expressed as relative standard deviation (RSD) and accuracies were less than 15%. The recoveries for MPA and MPAG from the collection device's swab were higher than 90%. Sample stability was confirmed for bench times up to 24 h at room temperature. The method was validated according to International Conference on Harmonization (ICH) guidelines Q2 (R1) Validation of Analytical Procedures. The applicability of the method was tested in a renal pediatric patient. Based on a limited sampling strategy, MPA saliva and plasma concentrations were found in good agreement with each other. We suggest that the described method is suitable to analyze saliva and plasma samples of small volumes for therapeutic drug monitoring (TDM) and pharmacokinetic studies in pediatric patients.

Authors+Show Affiliations

Division of TDM, Department of Pharmacology, University Hospital of Cologne, Cologne, Germany.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article

Language

eng

PubMed ID

22552204

Citation

Wiesen, Martin H J., et al. "Liquid Chromatography-tandem Mass Spectrometry Method for the Quantification of Mycophenolic Acid and Its Phenolic Glucuronide in Saliva and Plasma Using a Standardized Saliva Collection Device." Journal of Chromatography. A, vol. 1241, 2012, pp. 52-9.
Wiesen MH, Farowski F, Feldkötter M, et al. Liquid chromatography-tandem mass spectrometry method for the quantification of mycophenolic acid and its phenolic glucuronide in saliva and plasma using a standardized saliva collection device. J Chromatogr A. 2012;1241:52-9.
Wiesen, M. H., Farowski, F., Feldkötter, M., Hoppe, B., & Müller, C. (2012). Liquid chromatography-tandem mass spectrometry method for the quantification of mycophenolic acid and its phenolic glucuronide in saliva and plasma using a standardized saliva collection device. Journal of Chromatography. A, 1241, 52-9. https://doi.org/10.1016/j.chroma.2012.04.008
Wiesen MH, et al. Liquid Chromatography-tandem Mass Spectrometry Method for the Quantification of Mycophenolic Acid and Its Phenolic Glucuronide in Saliva and Plasma Using a Standardized Saliva Collection Device. J Chromatogr A. 2012 Jun 8;1241:52-9. PubMed PMID: 22552204.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Liquid chromatography-tandem mass spectrometry method for the quantification of mycophenolic acid and its phenolic glucuronide in saliva and plasma using a standardized saliva collection device. AU - Wiesen,Martin H J, AU - Farowski,Fedja, AU - Feldkötter,Markus, AU - Hoppe,Bernd, AU - Müller,Carsten, Y1 - 2012/04/11/ PY - 2011/11/25/received PY - 2012/03/23/revised PY - 2012/04/02/accepted PY - 2012/5/4/entrez PY - 2012/5/4/pubmed PY - 2012/7/18/medline SP - 52 EP - 9 JF - Journal of chromatography. A JO - J Chromatogr A VL - 1241 N2 - A liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for simultaneous quantification of mycophenolic acid (MPA) and its phenolic glucuronide (MPAG) in saliva and plasma. Saliva was collected and processed using a standardized commercially available collection device. Sample preparation comprised of protein precipitation with acetonitrile and subsequent centrifugation, followed by evaporation and reconstitution with mobile phase. A labeled isotope of MPA was used as internal standard, and chromatographic separation was achieved on a C18 column with an isocratic flow. LC-MS/MS detection was performed using a triple-stage quadrupole mass spectrometer working in selected reaction monitoring mode with positive electrospray ionization (ESI). The analytes were quantified in a single run within 2 min. For saliva, linearity was demonstrated over the concentration range of 5.0 to 400.0 ng/ml for both MPA and MPAG, and from 0.08 to 20.00 μg/ml for MPA and 0.4 to 100.0 μg/ml for MPAG in plasma. The lower limits of quantification for MPA and MPAG were 0.07 and 0.80 ng/ml in saliva, and 0.002 and 0.009 μg/ml in plasma, respectively. Inter- and intra-day precisions expressed as relative standard deviation (RSD) and accuracies were less than 15%. The recoveries for MPA and MPAG from the collection device's swab were higher than 90%. Sample stability was confirmed for bench times up to 24 h at room temperature. The method was validated according to International Conference on Harmonization (ICH) guidelines Q2 (R1) Validation of Analytical Procedures. The applicability of the method was tested in a renal pediatric patient. Based on a limited sampling strategy, MPA saliva and plasma concentrations were found in good agreement with each other. We suggest that the described method is suitable to analyze saliva and plasma samples of small volumes for therapeutic drug monitoring (TDM) and pharmacokinetic studies in pediatric patients. SN - 1873-3778 UR - https://www.unboundmedicine.com/medline/citation/22552204/Liquid_chromatography_tandem_mass_spectrometry_method_for_the_quantification_of_mycophenolic_acid_and_its_phenolic_glucuronide_in_saliva_and_plasma_using_a_standardized_saliva_collection_device_ L2 - https://linkinghub.elsevier.com/retrieve/pii/S0021-9673(12)00550-X DB - PRIME DP - Unbound Medicine ER -