Simultaneous determination of ascorbic acid, dopamine, uric acid and tryptophan on gold nanoparticles/overoxidized-polyimidazole composite modified glassy carbon electrode.
Anal Chim Acta. 2012 Sep 05; 741:15-20.AC

Abstract

A novel electrode was developed through electrodepositing gold nanoparticles (GNPs) on overoxidized-polyimidazole (PImox) film modified glassy carbon electrode (GCE). The combination of GNPs and the PImox film endowed the GNPs/PImox/GCE with good biological compatibility, high selectivity and sensitivity and excellent electrochemical catalytic activities towards ascorbic acid (AA), dopamine (DA), uric acid (UA) and tryptophan (Trp). In the fourfold co-existence system, the peak separations between AA-DA, DA-UA and UA-Trp were large up to 186, 165 and 285 mV, respectively. The calibration curves for AA, DA and UA were obtained in the range of 210.0-1010.0 μM, 5.0-268.0 μM and 6.0-486.0 μM with detection limits (S/N=3) of 2.0 μM, 0.08 μM and 0.5 μM, respectively. Two linear calibrations for Trp were obtained over ranges of 3.0-34.0 μM and 84.0-464.0 μM with detection limit (S/N=3) of 0.7 μM. In addition, the modified electrode was applied to detect AA, DA, UA and Trp in samples using standard addition method with satisfactory results.

Authors+Show Affiliations

Education Ministry Key Laboratory on Luminescence and Real-Time Analysis, College of Chemistry and Chemical Engineering, Southwest University, Chongqing 400715, China.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

22840700

Citation

Wang, Cun, et al. "Simultaneous Determination of Ascorbic Acid, Dopamine, Uric Acid and Tryptophan On Gold Nanoparticles/overoxidized-polyimidazole Composite Modified Glassy Carbon Electrode." Analytica Chimica Acta, vol. 741, 2012, pp. 15-20.
Wang C, Yuan R, Chai Y, et al. Simultaneous determination of ascorbic acid, dopamine, uric acid and tryptophan on gold nanoparticles/overoxidized-polyimidazole composite modified glassy carbon electrode. Anal Chim Acta. 2012;741:15-20.
Wang, C., Yuan, R., Chai, Y., Chen, S., Hu, F., & Zhang, M. (2012). Simultaneous determination of ascorbic acid, dopamine, uric acid and tryptophan on gold nanoparticles/overoxidized-polyimidazole composite modified glassy carbon electrode. Analytica Chimica Acta, 741, 15-20. https://doi.org/10.1016/j.aca.2012.06.045
Wang C, et al. Simultaneous Determination of Ascorbic Acid, Dopamine, Uric Acid and Tryptophan On Gold Nanoparticles/overoxidized-polyimidazole Composite Modified Glassy Carbon Electrode. Anal Chim Acta. 2012 Sep 5;741:15-20. PubMed PMID: 22840700.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Simultaneous determination of ascorbic acid, dopamine, uric acid and tryptophan on gold nanoparticles/overoxidized-polyimidazole composite modified glassy carbon electrode. AU - Wang,Cun, AU - Yuan,Ruo, AU - Chai,Yaqin, AU - Chen,Shihong, AU - Hu,Fangxin, AU - Zhang,Meihe, Y1 - 2012/07/04/ PY - 2012/03/13/received PY - 2012/06/18/revised PY - 2012/06/19/accepted PY - 2012/7/31/entrez PY - 2012/7/31/pubmed PY - 2013/3/19/medline SP - 15 EP - 20 JF - Analytica chimica acta JO - Anal Chim Acta VL - 741 N2 - A novel electrode was developed through electrodepositing gold nanoparticles (GNPs) on overoxidized-polyimidazole (PImox) film modified glassy carbon electrode (GCE). The combination of GNPs and the PImox film endowed the GNPs/PImox/GCE with good biological compatibility, high selectivity and sensitivity and excellent electrochemical catalytic activities towards ascorbic acid (AA), dopamine (DA), uric acid (UA) and tryptophan (Trp). In the fourfold co-existence system, the peak separations between AA-DA, DA-UA and UA-Trp were large up to 186, 165 and 285 mV, respectively. The calibration curves for AA, DA and UA were obtained in the range of 210.0-1010.0 μM, 5.0-268.0 μM and 6.0-486.0 μM with detection limits (S/N=3) of 2.0 μM, 0.08 μM and 0.5 μM, respectively. Two linear calibrations for Trp were obtained over ranges of 3.0-34.0 μM and 84.0-464.0 μM with detection limit (S/N=3) of 0.7 μM. In addition, the modified electrode was applied to detect AA, DA, UA and Trp in samples using standard addition method with satisfactory results. SN - 1873-4324 UR - https://www.unboundmedicine.com/medline/citation/22840700/Simultaneous_determination_of_ascorbic_acid_dopamine_uric_acid_and_tryptophan_on_gold_nanoparticles/overoxidized_polyimidazole_composite_modified_glassy_carbon_electrode_ L2 - https://linkinghub.elsevier.com/retrieve/pii/S0003-2670(12)00965-8 DB - PRIME DP - Unbound Medicine ER -