Citation
He, Qianqian, et al. "Simultaneous Determination of Quinoxaline-1,4-dioxides in Feeds Using Molecularly Imprinted Solid-phase Extraction Coupled With HPLC." Journal of Separation Science, vol. 36, no. 2, 2013, pp. 301-10.
He Q, Fang B, Su Y, et al. Simultaneous determination of quinoxaline-1,4-dioxides in feeds using molecularly imprinted solid-phase extraction coupled with HPLC. J Sep Sci. 2013;36(2):301-10.
He, Q., Fang, B., Su, Y., Zeng, Z., Yang, J., He, L., & Zeng, D. (2013). Simultaneous determination of quinoxaline-1,4-dioxides in feeds using molecularly imprinted solid-phase extraction coupled with HPLC. Journal of Separation Science, 36(2), 301-10. https://doi.org/10.1002/jssc.201200701
He Q, et al. Simultaneous Determination of Quinoxaline-1,4-dioxides in Feeds Using Molecularly Imprinted Solid-phase Extraction Coupled With HPLC. J Sep Sci. 2013;36(2):301-10. PubMed PMID: 23335457.
TY - JOUR
T1 - Simultaneous determination of quinoxaline-1,4-dioxides in feeds using molecularly imprinted solid-phase extraction coupled with HPLC.
AU - He,Qianqian,
AU - Fang,Binghu,
AU - Su,Yijuan,
AU - Zeng,Zhenling,
AU - Yang,Jianwen,
AU - He,Limin,
AU - Zeng,Dongping,
Y1 - 2012/12/10/
PY - 2012/07/23/received
PY - 2012/09/10/revised
PY - 2012/09/14/accepted
PY - 2013/1/22/entrez
PY - 2013/1/22/pubmed
PY - 2013/6/26/medline
SP - 301
EP - 10
JF - Journal of separation science
JO - J Sep Sci
VL - 36
IS - 2
N2 - A simple, selective, and reproducible molecularly imprinted SPE coupled with HPLC method was developed for monitoring quinoxaline-1,4-dioxides in feeds. Molecularly imprinted polymers were synthesized in methanol using mequindox (MEQ) as template molecule and acrylamide as functional monomer by bulk polymerization. Under the optimum SPE conditions, the novel polymer sorbents can selectively extract and enrich carbadox, MEQ, quinocetone, and cyadox from a variety of feeds. The molecularly imprinted SPE cartridge was better than nonimprinted, C(18) , and HLB cartridges in terms of both recovery and precision. Mean recoveries of four quinoxaline-1,4-dioxides from six kinds of feeds spiked at 1.0, 10, and 100 mg/kg ranged between 75.2 and 94.7% with RSDs of less than 10%. The decision limits (CCαs) and the detection capabilities (CCβs) of four analytes were 0.15-0.20 mg/kg and 0.44-0.56 mg/kg, respectively. The class selectivity of the polymers was evaluated by checking three drugs with different molecular structures to that of MEQ.
SN - 1615-9314
UR - https://www.unboundmedicine.com/medline/citation/23335457/Simultaneous_determination_of_quinoxaline_14_dioxides_in_feeds_using_molecularly_imprinted_solid_phase_extraction_coupled_with_HPLC_
L2 - https://doi.org/10.1002/jssc.201200701
DB - PRIME
DP - Unbound Medicine
ER -