Tags

Type your tag names separated by a space and hit enter

Identification of impurities in methotrexate drug substances using high-performance liquid chromatography coupled with a photodiode array detector and Fourier transform ion cyclotron resonance mass spectrometry.
Rapid Commun Mass Spectrom. 2013 May 15; 27(9):971-8.RC

Abstract

RATIONALE

Methotrexate (MTX) is an antineoplastic therapeutic medicine that acts as an antimetabolite of folic acid. In this study we identified the impurities in MTX drug substances produced by different manufacturers and in different batches using high-performance liquid chromatography coupled with a photodiode array detector and Fourier transform ion cyclotron resonance mass spectrometry (HPLC-PDA/FTICR-MS).

METHODS

MTX and its impurities were separated on a Restek Pinnacle II C18 column (250 × 4.6 mm, 5 µm) with a gradient elution system composed of 0.2% formic acid and acetonitrile at a flow rate of 1.0 mL/min. Ultraviolet (UV) detection was set at 305 nm. Mass detection was carried out using FTICR-MS with full-scan mass analysis at a resolving power of 100 000 coupled with multiple-stage mass analysis using a parent list of compounds.

RESULTS

Fifteen impurities were detected in MTX drug substances, and their structures were predicted from using HPLC-PDA/FTICR-MS data, including their UV spectra, high-resolution mass spectrometry (HRMS), fragmentation patterns, and MS(n) spectra. Ten of the impurities detected in the MTX drug substances are reported for the first time. There was a high abundance of esterified impurities in some batches of MTX drug substances, over the identification threshold of International Conference on Harmonization (ICH) guidelines, which requires particular attention.

CONCLUSIONS

This paper describes a HPLC-PDA/FTICR-MS method to profile and identify impurities in MTX drug substances. The results suggest that HPLC-PDA/FTICR-MS is a valuable analytical technique for the rapid identification of impurities.

Authors+Show Affiliations

State Key Laboratory of Bioactive Substance and Function of Natural Medicines, Institute of Materia Medica, Chinese Academy of Medical Sciences and Peking Union Medical College, Beijing, China.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

23592199

Citation

Wu, Cai-Sheng, et al. "Identification of Impurities in Methotrexate Drug Substances Using High-performance Liquid Chromatography Coupled With a Photodiode Array Detector and Fourier Transform Ion Cyclotron Resonance Mass Spectrometry." Rapid Communications in Mass Spectrometry : RCM, vol. 27, no. 9, 2013, pp. 971-8.
Wu CS, Tong YF, Wang PY, et al. Identification of impurities in methotrexate drug substances using high-performance liquid chromatography coupled with a photodiode array detector and Fourier transform ion cyclotron resonance mass spectrometry. Rapid Commun Mass Spectrom. 2013;27(9):971-8.
Wu, C. S., Tong, Y. F., Wang, P. Y., Wang, D. M., Wu, S., & Zhang, J. L. (2013). Identification of impurities in methotrexate drug substances using high-performance liquid chromatography coupled with a photodiode array detector and Fourier transform ion cyclotron resonance mass spectrometry. Rapid Communications in Mass Spectrometry : RCM, 27(9), 971-8. https://doi.org/10.1002/rcm.6535
Wu CS, et al. Identification of Impurities in Methotrexate Drug Substances Using High-performance Liquid Chromatography Coupled With a Photodiode Array Detector and Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Rapid Commun Mass Spectrom. 2013 May 15;27(9):971-8. PubMed PMID: 23592199.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Identification of impurities in methotrexate drug substances using high-performance liquid chromatography coupled with a photodiode array detector and Fourier transform ion cyclotron resonance mass spectrometry. AU - Wu,Cai-Sheng, AU - Tong,Yuan-Feng, AU - Wang,Peng-Yuan, AU - Wang,Dong-Mei, AU - Wu,Song, AU - Zhang,Jin-Lan, PY - 2012/12/05/received PY - 2013/02/04/revised PY - 2013/02/05/accepted PY - 2013/4/18/entrez PY - 2013/4/18/pubmed PY - 2013/10/22/medline SP - 971 EP - 8 JF - Rapid communications in mass spectrometry : RCM JO - Rapid Commun Mass Spectrom VL - 27 IS - 9 N2 - RATIONALE: Methotrexate (MTX) is an antineoplastic therapeutic medicine that acts as an antimetabolite of folic acid. In this study we identified the impurities in MTX drug substances produced by different manufacturers and in different batches using high-performance liquid chromatography coupled with a photodiode array detector and Fourier transform ion cyclotron resonance mass spectrometry (HPLC-PDA/FTICR-MS). METHODS: MTX and its impurities were separated on a Restek Pinnacle II C18 column (250 × 4.6 mm, 5 µm) with a gradient elution system composed of 0.2% formic acid and acetonitrile at a flow rate of 1.0 mL/min. Ultraviolet (UV) detection was set at 305 nm. Mass detection was carried out using FTICR-MS with full-scan mass analysis at a resolving power of 100 000 coupled with multiple-stage mass analysis using a parent list of compounds. RESULTS: Fifteen impurities were detected in MTX drug substances, and their structures were predicted from using HPLC-PDA/FTICR-MS data, including their UV spectra, high-resolution mass spectrometry (HRMS), fragmentation patterns, and MS(n) spectra. Ten of the impurities detected in the MTX drug substances are reported for the first time. There was a high abundance of esterified impurities in some batches of MTX drug substances, over the identification threshold of International Conference on Harmonization (ICH) guidelines, which requires particular attention. CONCLUSIONS: This paper describes a HPLC-PDA/FTICR-MS method to profile and identify impurities in MTX drug substances. The results suggest that HPLC-PDA/FTICR-MS is a valuable analytical technique for the rapid identification of impurities. SN - 1097-0231 UR - https://www.unboundmedicine.com/medline/citation/23592199/Identification_of_impurities_in_methotrexate_drug_substances_using_high_performance_liquid_chromatography_coupled_with_a_photodiode_array_detector_and_Fourier_transform_ion_cyclotron_resonance_mass_spectrometry_ L2 - https://doi.org/10.1002/rcm.6535 DB - PRIME DP - Unbound Medicine ER -