Tags

Type your tag names separated by a space and hit enter

A new silylation reagent dimethyl(3,3,3-trifluoropropyl)silyldiethylamine for the analysis of estrogenic compounds by gas chromatography-mass spectrometry.
J Chromatogr A. 2013 Aug 02; 1301:215-24.JC

Abstract

In this study we applied DIMETRIS (dimethyl(3,3,3-trifluoropropyl)silyldiethylamine), a new silylating reagent, to derivative natural estrogens such as estrone (E1), 17β-estradiol (E2) and estriol (E3), as well as the synthetic 17α-ethinylestradiol (EE2) and the non-steroid diethylstilbestrol (DES). Its derivatizing properties were compared with those of the commonly used mixture of BSTFA (N,O-bis(trimethylsilyl)trifluoroacetamide)+1% trimethylchlorosilane (TMCS) and with MTBSTFA (N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide). The use of DIMETRIS for the silylation all of them is reported for the first time. The nucleophilic properties of DIMETRIS were found to be superior to those of MTBSTFA, but slightly inferior to those of BSTFA. It was used to derivatize steroid (E1, E2, E3 and EE2) and non-steroid (DES) estrogens at 30°C prior to GC/MS analysis. These DMTFPS-derivatives exhibited good separation (low retention times despite the high molecular masses) and ionization properties in GC/MS analyses (the highest relative response factors for DMTFPS-derivatives among those tested). However, DIMETRIS and MTBSTFA (which produce mono-O-silyl derivatives of EE2) should not be used for the simultaneous analysis of EE2 and E1. Only a mixture of BSTFA+1% TMCS in pyridine, which generates the fully derivatized EE2 product (stable in GC injector), permits the determination of these two estrogenic compounds during one GC-MS run. On the other hand, because DIMETRIS requires a lower derivatization temperature than BSTFA, it could be very useful for the derivatization of thermally unstable estrogenic compounds. In the next step of this study, the SPE-GC-MS method based on DIMETRIS derivatization for the analysis of DES, E2 and E3 in aqueous samples was evaluated and validated. The MQL values: 1.4, 1.6 and 1.5ngL(-1) for DES, E2 and E3, respectively, proved its suitability to determine target compounds in environmental samples. Finally, the proposed method was successfully applied to the analysis of selected estrogenic compounds in real seawater and wastewater samples in Poland.

Authors+Show Affiliations

Institute for Environmental and Human Health Protection, Faculty of Chemistry, University of Gdansk, Sobieskiego 18/19, 80-952 Gdansk, Poland.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

23806354

Citation

Caban, Magda, et al. "A New Silylation Reagent Dimethyl(3,3,3-trifluoropropyl)silyldiethylamine for the Analysis of Estrogenic Compounds By Gas Chromatography-mass Spectrometry." Journal of Chromatography. A, vol. 1301, 2013, pp. 215-24.
Caban M, Czerwicka M, Łukaszewicz P, et al. A new silylation reagent dimethyl(3,3,3-trifluoropropyl)silyldiethylamine for the analysis of estrogenic compounds by gas chromatography-mass spectrometry. J Chromatogr A. 2013;1301:215-24.
Caban, M., Czerwicka, M., Łukaszewicz, P., Migowska, N., Stepnowski, P., Kwiatkowski, M., & Kumirska, J. (2013). A new silylation reagent dimethyl(3,3,3-trifluoropropyl)silyldiethylamine for the analysis of estrogenic compounds by gas chromatography-mass spectrometry. Journal of Chromatography. A, 1301, 215-24. https://doi.org/10.1016/j.chroma.2013.05.073
Caban M, et al. A New Silylation Reagent Dimethyl(3,3,3-trifluoropropyl)silyldiethylamine for the Analysis of Estrogenic Compounds By Gas Chromatography-mass Spectrometry. J Chromatogr A. 2013 Aug 2;1301:215-24. PubMed PMID: 23806354.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - A new silylation reagent dimethyl(3,3,3-trifluoropropyl)silyldiethylamine for the analysis of estrogenic compounds by gas chromatography-mass spectrometry. AU - Caban,Magda, AU - Czerwicka,Małgorzata, AU - Łukaszewicz,Paulina, AU - Migowska,Natalia, AU - Stepnowski,Piotr, AU - Kwiatkowski,Marek, AU - Kumirska,Jolanta, Y1 - 2013/06/06/ PY - 2013/03/26/received PY - 2013/05/29/revised PY - 2013/05/30/accepted PY - 2013/6/29/entrez PY - 2013/6/29/pubmed PY - 2014/1/22/medline KW - Comparative study KW - DIMETRIS KW - Estrogenic compounds KW - Fragmentation pattern KW - Mass spectra analysis KW - Silylation SP - 215 EP - 24 JF - Journal of chromatography. A JO - J Chromatogr A VL - 1301 N2 - In this study we applied DIMETRIS (dimethyl(3,3,3-trifluoropropyl)silyldiethylamine), a new silylating reagent, to derivative natural estrogens such as estrone (E1), 17β-estradiol (E2) and estriol (E3), as well as the synthetic 17α-ethinylestradiol (EE2) and the non-steroid diethylstilbestrol (DES). Its derivatizing properties were compared with those of the commonly used mixture of BSTFA (N,O-bis(trimethylsilyl)trifluoroacetamide)+1% trimethylchlorosilane (TMCS) and with MTBSTFA (N-tert-butyldimethylsilyl-N-methyltrifluoroacetamide). The use of DIMETRIS for the silylation all of them is reported for the first time. The nucleophilic properties of DIMETRIS were found to be superior to those of MTBSTFA, but slightly inferior to those of BSTFA. It was used to derivatize steroid (E1, E2, E3 and EE2) and non-steroid (DES) estrogens at 30°C prior to GC/MS analysis. These DMTFPS-derivatives exhibited good separation (low retention times despite the high molecular masses) and ionization properties in GC/MS analyses (the highest relative response factors for DMTFPS-derivatives among those tested). However, DIMETRIS and MTBSTFA (which produce mono-O-silyl derivatives of EE2) should not be used for the simultaneous analysis of EE2 and E1. Only a mixture of BSTFA+1% TMCS in pyridine, which generates the fully derivatized EE2 product (stable in GC injector), permits the determination of these two estrogenic compounds during one GC-MS run. On the other hand, because DIMETRIS requires a lower derivatization temperature than BSTFA, it could be very useful for the derivatization of thermally unstable estrogenic compounds. In the next step of this study, the SPE-GC-MS method based on DIMETRIS derivatization for the analysis of DES, E2 and E3 in aqueous samples was evaluated and validated. The MQL values: 1.4, 1.6 and 1.5ngL(-1) for DES, E2 and E3, respectively, proved its suitability to determine target compounds in environmental samples. Finally, the proposed method was successfully applied to the analysis of selected estrogenic compounds in real seawater and wastewater samples in Poland. SN - 1873-3778 UR - https://www.unboundmedicine.com/medline/citation/23806354/A_new_silylation_reagent_dimethyl_333_trifluoropropyl_silyldiethylamine_for_the_analysis_of_estrogenic_compounds_by_gas_chromatography_mass_spectrometry_ L2 - https://linkinghub.elsevier.com/retrieve/pii/S0021-9673(13)00853-4 DB - PRIME DP - Unbound Medicine ER -