Contasure-Needleless® single incision sling compared with transobturator TVT-O® for the treatment of stress urinary incontinence: long-term results.
Int Urogynecol J. 2015 Feb; 26(2):213-8.IU

Abstract

INTRODUCTION AND HYPOTHESIS

This study compared transobturator tension-free vaginal tape (TVT-O®) and Contasure-Needleless (C-NDL®) at long-term follow-up .

METHODS

Non-inferiority, prospective, single-centre , quasi-randomised trial started in September 2006 and finished in April 2011 to compare C-NDL® with transobturator vaginal tape (TVT-O®) mesh in the treatment of stress urinary incontinence (SUI) . Epidemiological information, intraoperative and postoperative complications, subjective estimates of blood loss and pain levels were recorded. We also analysed the postoperative stress test, the subjective impression of improvement using the Sandvik Severity Index and the quality of life during follow-up using the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) .

RESULTS

Two hundred and fifty-seven women with primary SUI were scheduled to receive TVT-O® or C-NDL® and were followed up at least 3 years after the procedure . One hundred and eleven women in the C-NDL® group (84.7%) had a negative stress test, compared with 54 women (88.9%) in the TVT-O® group (p = 0.0065 for the non-inferiority test). The postoperative Sandvik Severity Index was 0 or better than the preoperative score in 90.7% of patients in the C-NDL® group and 95.4% of patients in the TVT-O® group (p = 0.0022). The complication rate was similar in both groups. There were significant differences (p = 0.02) in postoperative pain within the TVT-O® group. The degree of satisfaction was not statistically significant between the two groups.

CONCLUSIONS

The outcomes for the C-NDL® group were similar to those of the TVT-O® group, adding the concept of "single incision tape" to the tension-free sling option.

Authors+Show Affiliations

Pelvic Floor Unit, Obstetrics and Gynaecologic Department, Hospital Sant Joan de Déu, Passeig Sant Joan de Déu, 2, 08950, Esplugues de Llobregat (Barcelona) , Spain, emartinez@hsjdbcn.org.No affiliation info available

Pub Type(s)

Comparative Study
Journal Article
Randomized Controlled Trial

Language

eng

PubMed ID

25030327

Citation

Martinez Franco, Eva, and Lluís Amat Tardiu. "Contasure-Needleless® Single Incision Sling Compared With Transobturator TVT-O® for the Treatment of Stress Urinary Incontinence: Long-term Results." International Urogynecology Journal, vol. 26, no. 2, 2015, pp. 213-8.
Martinez Franco E, Amat Tardiu L. Contasure-Needleless® single incision sling compared with transobturator TVT-O® for the treatment of stress urinary incontinence: long-term results. Int Urogynecol J. 2015;26(2):213-8.
Martinez Franco, E., & Amat Tardiu, L. (2015). Contasure-Needleless® single incision sling compared with transobturator TVT-O® for the treatment of stress urinary incontinence: long-term results. International Urogynecology Journal, 26(2), 213-8. https://doi.org/10.1007/s00192-014-2475-x
Martinez Franco E, Amat Tardiu L. Contasure-Needleless® Single Incision Sling Compared With Transobturator TVT-O® for the Treatment of Stress Urinary Incontinence: Long-term Results. Int Urogynecol J. 2015;26(2):213-8. PubMed PMID: 25030327.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Contasure-Needleless® single incision sling compared with transobturator TVT-O® for the treatment of stress urinary incontinence: long-term results. AU - Martinez Franco,Eva, AU - Amat Tardiu,Lluís, Y1 - 2014/07/17/ PY - 2014/04/11/received PY - 2014/06/26/accepted PY - 2014/7/18/entrez PY - 2014/7/18/pubmed PY - 2015/10/27/medline SP - 213 EP - 8 JF - International urogynecology journal JO - Int Urogynecol J VL - 26 IS - 2 N2 - INTRODUCTION AND HYPOTHESIS: This study compared transobturator tension-free vaginal tape (TVT-O®) and Contasure-Needleless (C-NDL®) at long-term follow-up . METHODS: Non-inferiority, prospective, single-centre , quasi-randomised trial started in September 2006 and finished in April 2011 to compare C-NDL® with transobturator vaginal tape (TVT-O®) mesh in the treatment of stress urinary incontinence (SUI) . Epidemiological information, intraoperative and postoperative complications, subjective estimates of blood loss and pain levels were recorded. We also analysed the postoperative stress test, the subjective impression of improvement using the Sandvik Severity Index and the quality of life during follow-up using the International Consultation on Incontinence Questionnaire-Short Form (ICIQ-SF) . RESULTS: Two hundred and fifty-seven women with primary SUI were scheduled to receive TVT-O® or C-NDL® and were followed up at least 3 years after the procedure . One hundred and eleven women in the C-NDL® group (84.7%) had a negative stress test, compared with 54 women (88.9%) in the TVT-O® group (p = 0.0065 for the non-inferiority test). The postoperative Sandvik Severity Index was 0 or better than the preoperative score in 90.7% of patients in the C-NDL® group and 95.4% of patients in the TVT-O® group (p = 0.0022). The complication rate was similar in both groups. There were significant differences (p = 0.02) in postoperative pain within the TVT-O® group. The degree of satisfaction was not statistically significant between the two groups. CONCLUSIONS: The outcomes for the C-NDL® group were similar to those of the TVT-O® group, adding the concept of "single incision tape" to the tension-free sling option. SN - 1433-3023 UR - https://www.unboundmedicine.com/medline/citation/25030327/Contasure_Needleless®_single_incision_sling_compared_with_transobturator_TVT_O®_for_the_treatment_of_stress_urinary_incontinence:_long_term_results_ L2 - https://dx.doi.org/10.1007/s00192-014-2475-x DB - PRIME DP - Unbound Medicine ER -