Tags

Type your tag names separated by a space and hit enter

Simultaneous Determination of Bosentan, Glimepiride, HYBOS and M1 in Rat Plasma by UPLC-MS-MS and its Application to Pharmacokinetic Study.
J Chromatogr Sci. 2016 Aug; 54(7):1159-65.JC

Abstract

A rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method for the simultaneous determination of bosentan (BOS), glimepiride (GLP), hydroxyl bosentan (HYBOS) and hydroxyl glimepiride (M1) in rat plasma using one-step protein precipitation was developed and validated. After addition of ambrisentan as an internal standard (IS), protein precipitation by acetonitrile was used in sample preparation. Chromatographic separation was achieved on a Waters ACQUITY UPLC BEH C18 column (2.1 mm × 100 mm, 1.7 μm particle size, Waters Corp., Milford, MA, USA) and inline 0.2 μm stainless steel frit filter (Waters Corp.) with acetonitrile-0.1% formic acid as the mobile phase at a flow rate of 0.4 mL/min with gradient elution. The column temperature was maintained at 40°C. Only 4 min was needed for an analytical run. The retention times were ∼3.29 min for BOS, 3.56 min for GLP, 1.42 min for HYBOS, 1.53 min for M1 and 3.22 min for IS. Electrospray ionization source was employed and operated in positive-ion mode; multiple reaction monitoring mode was applied to target fragment ions m/z 552 → 202, m/z 568 → 202, m/z 491 → 352, m/z 507 → 352 and m/z 379 → 347 for BOS, HYBOS, GLP, M1 and IS, respectively. The assay was validated over concentration ranges of 25-5,000 ng/mL (r(2) = 0.9984) for BOS, 1-200 ng/mL (r(2) = 0.9999) for GLP, 0.5-100 ng/mL (r(2) = 0.9999) for HYBOS and 0.1-20 ng/mL (r(2) = 0.9984) for M1. Intra- and interday precision values for replicate quality control samples were within 14.2% for all analytes during the assay validation. Mean quality control accuracy values were within -3.3 to 14.4% of nominal values for all analytes. The mean recoveries of BOS, GLP, HYBOS, M1 and ambrisentan from the plasma exceeded 90.4%. The analytes were stable in rat plasma for at least 2 h at room temperature, 30 days at -40°C and following at least three freeze-thaw cycles (-40°C to room temperature). This method was successfully applied to a pharmacokinetic study of coadministeration of BOS and GLP in rats.

Authors+Show Affiliations

The 2nd Affiliated Hospital, Wenzhou Medical University, Wenzhou, Zhejiang 325000, China School of Pharmacy of Wenzhou Medical University, Wenzhou, Zhejiang 325000, China.The 2nd Affiliated Hospital, Wenzhou Medical University, Wenzhou, Zhejiang 325000, China.The Laboratory of Clinical Pharmacy, People's Hospital of Lishui City, Lishui, Zhejiang 323000, China.School of Pharmacy of Wenzhou Medical University, Wenzhou, Zhejiang 325000, China.School of Pharmacy of Wenzhou Medical University, Wenzhou, Zhejiang 325000, China.School of Pharmacy of Wenzhou Medical University, Wenzhou, Zhejiang 325000, China.School of Pharmacy of Wenzhou Medical University, Wenzhou, Zhejiang 325000, China.The 2nd Affiliated Hospital, Wenzhou Medical University, Wenzhou, Zhejiang 325000, China zhe_zhi2000@aliyun.com.

Pub Type(s)

Journal Article
Validation Study

Language

eng

PubMed ID

27240565

Citation

Chen, Mengchun, et al. "Simultaneous Determination of Bosentan, Glimepiride, HYBOS and M1 in Rat Plasma By UPLC-MS-MS and Its Application to Pharmacokinetic Study." Journal of Chromatographic Science, vol. 54, no. 7, 2016, pp. 1159-65.
Chen M, Song W, Wang S, et al. Simultaneous Determination of Bosentan, Glimepiride, HYBOS and M1 in Rat Plasma by UPLC-MS-MS and its Application to Pharmacokinetic Study. J Chromatogr Sci. 2016;54(7):1159-65.
Chen, M., Song, W., Wang, S., Chen, Q., Pan, P., Xu, T., Hu, G., & Zheng, Z. (2016). Simultaneous Determination of Bosentan, Glimepiride, HYBOS and M1 in Rat Plasma by UPLC-MS-MS and its Application to Pharmacokinetic Study. Journal of Chromatographic Science, 54(7), 1159-65. https://doi.org/10.1093/chromsci/bmw003
Chen M, et al. Simultaneous Determination of Bosentan, Glimepiride, HYBOS and M1 in Rat Plasma By UPLC-MS-MS and Its Application to Pharmacokinetic Study. J Chromatogr Sci. 2016;54(7):1159-65. PubMed PMID: 27240565.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Simultaneous Determination of Bosentan, Glimepiride, HYBOS and M1 in Rat Plasma by UPLC-MS-MS and its Application to Pharmacokinetic Study. AU - Chen,Mengchun, AU - Song,Wenjie, AU - Wang,Shuanghu, AU - Chen,Qiulei, AU - Pan,Peipei, AU - Xu,Tao, AU - Hu,Guoxin, AU - Zheng,Zhiqiang, Y1 - 2016/05/30/ PY - 2014/10/22/received PY - 2016/6/1/entrez PY - 2016/6/1/pubmed PY - 2018/2/6/medline SP - 1159 EP - 65 JF - Journal of chromatographic science JO - J Chromatogr Sci VL - 54 IS - 7 N2 - A rapid and sensitive ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS-MS) method for the simultaneous determination of bosentan (BOS), glimepiride (GLP), hydroxyl bosentan (HYBOS) and hydroxyl glimepiride (M1) in rat plasma using one-step protein precipitation was developed and validated. After addition of ambrisentan as an internal standard (IS), protein precipitation by acetonitrile was used in sample preparation. Chromatographic separation was achieved on a Waters ACQUITY UPLC BEH C18 column (2.1 mm × 100 mm, 1.7 μm particle size, Waters Corp., Milford, MA, USA) and inline 0.2 μm stainless steel frit filter (Waters Corp.) with acetonitrile-0.1% formic acid as the mobile phase at a flow rate of 0.4 mL/min with gradient elution. The column temperature was maintained at 40°C. Only 4 min was needed for an analytical run. The retention times were ∼3.29 min for BOS, 3.56 min for GLP, 1.42 min for HYBOS, 1.53 min for M1 and 3.22 min for IS. Electrospray ionization source was employed and operated in positive-ion mode; multiple reaction monitoring mode was applied to target fragment ions m/z 552 → 202, m/z 568 → 202, m/z 491 → 352, m/z 507 → 352 and m/z 379 → 347 for BOS, HYBOS, GLP, M1 and IS, respectively. The assay was validated over concentration ranges of 25-5,000 ng/mL (r(2) = 0.9984) for BOS, 1-200 ng/mL (r(2) = 0.9999) for GLP, 0.5-100 ng/mL (r(2) = 0.9999) for HYBOS and 0.1-20 ng/mL (r(2) = 0.9984) for M1. Intra- and interday precision values for replicate quality control samples were within 14.2% for all analytes during the assay validation. Mean quality control accuracy values were within -3.3 to 14.4% of nominal values for all analytes. The mean recoveries of BOS, GLP, HYBOS, M1 and ambrisentan from the plasma exceeded 90.4%. The analytes were stable in rat plasma for at least 2 h at room temperature, 30 days at -40°C and following at least three freeze-thaw cycles (-40°C to room temperature). This method was successfully applied to a pharmacokinetic study of coadministeration of BOS and GLP in rats. SN - 1945-239X UR - https://www.unboundmedicine.com/medline/citation/27240565/Simultaneous_Determination_of_Bosentan_Glimepiride_HYBOS_and_M1_in_Rat_Plasma_by_UPLC_MS_MS_and_its_Application_to_Pharmacokinetic_Study_ DB - PRIME DP - Unbound Medicine ER -