Tags

Type your tag names separated by a space and hit enter

Labor Analgesia Onset With Dural Puncture Epidural Versus Traditional Epidural Using a 26-Gauge Whitacre Needle and 0.125% Bupivacaine Bolus: A Randomized Clinical Trial.
Anesth Analg. 2018 02; 126(2):545-551.A&A

Abstract

BACKGROUND

Lumbar epidurals (LEs) provide excellent analgesia. Combined spinal epidural and dural puncture epidural (DPE) are 2 techniques to expedite neuraxial analgesia onset. In DPE, dura is punctured but medication is not administered in the cerebrospinal fluid. Expedited analgesia onset has been demonstrated with DPE, using 0.25% bupivacaine; however, this concentration may impede an unassisted vaginal birth and is not currently used for induction and maintenance of labor analgesia. The primary goal of this study was to compare the percentage of patients who achieved adequate labor analgesia following DPE or LE with an epidural bolus of 0.125% bupivacaine. Adequate labor analgesia was defined as Visual Analog Scale (VAS) measurement ≤ 10 mm on a 100-mm scale during active contractions, measured 10 minutes after epidural bolus initiation.

METHODS

Laboring patients were randomly assigned to receive LE or DPE. Immediately before epidural placement, subjects marked a VAS score during an active contraction and parturients with VAS < 50 mm were excluded. The epidural space was identified by a loss of resistance technique to saline (17G Tuohy needle [Arrow International, Inc, Redding, PA]). In the DPE group, dura was punctured with a 26G Whitacre needle (Arrow International, Inc). In all participants, a 19G epidural catheter (Arrow International, Inc) was inserted. An epidural bolus was then administered over 3 minutes (12 mL, 0.125% bupivacaine, 50 μg fentanyl) followed by infusion (0.1% bupivacaine, 2 μg/mL fentanyl). After initiation of epidural bolus (time zero), VAS measurements were collected at 2-minute intervals for up to 20 minutes. Median time to achieve adequate analgesia by treatment group was assessed by Kaplan-Meier analysis. Time to achieving adequate analgesia was evaluated using a Cox regression model. All analyses were conducted in SAS version 9.4. (SAS Institute, Cary, NC) RESULTS:: Data were analyzed from 80 participants (40 per group). Adequate analgesia at 10 minutes did not differ by neuraxial technique (DPE = 55.3% vs LE = 44.7%; P= .256). However, parturients receiving DPE had shorter median times to adequate analgesia (median [95% confidence interval], 8 minutes [6-10] vs 10 minutes [8-14]) and a 67% increase in the relative risk of achieving adequate analgesia compared to LE (relative risk = 1.67; 95% confidence interval, 1.02-2.64; P= .042).

CONCLUSIONS

Although the percentage of parturients achieving adequate labor analgesia at 10 minutes after epidural bolus did not differ by technique, DPE was associated with faster time to VAS ≤ 10 mm compared with LE.

Authors+Show Affiliations

From the Department of Anesthesia and Perioperative Medicine, Medical University of South Carolina, Charleston, South Carolina.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Comparative Study
Journal Article
Randomized Controlled Trial
Research Support, Non-U.S. Gov't

Language

eng

PubMed ID

28622178

Citation

Wilson, Sylvia H., et al. "Labor Analgesia Onset With Dural Puncture Epidural Versus Traditional Epidural Using a 26-Gauge Whitacre Needle and 0.125% Bupivacaine Bolus: a Randomized Clinical Trial." Anesthesia and Analgesia, vol. 126, no. 2, 2018, pp. 545-551.
Wilson SH, Wolf BJ, Bingham K, et al. Labor Analgesia Onset With Dural Puncture Epidural Versus Traditional Epidural Using a 26-Gauge Whitacre Needle and 0.125% Bupivacaine Bolus: A Randomized Clinical Trial. Anesth Analg. 2018;126(2):545-551.
Wilson, S. H., Wolf, B. J., Bingham, K., Scotland, Q. S., Fox, J. M., Woltz, E. M., & Hebbar, L. (2018). Labor Analgesia Onset With Dural Puncture Epidural Versus Traditional Epidural Using a 26-Gauge Whitacre Needle and 0.125% Bupivacaine Bolus: A Randomized Clinical Trial. Anesthesia and Analgesia, 126(2), 545-551. https://doi.org/10.1213/ANE.0000000000002129
Wilson SH, et al. Labor Analgesia Onset With Dural Puncture Epidural Versus Traditional Epidural Using a 26-Gauge Whitacre Needle and 0.125% Bupivacaine Bolus: a Randomized Clinical Trial. Anesth Analg. 2018;126(2):545-551. PubMed PMID: 28622178.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Labor Analgesia Onset With Dural Puncture Epidural Versus Traditional Epidural Using a 26-Gauge Whitacre Needle and 0.125% Bupivacaine Bolus: A Randomized Clinical Trial. AU - Wilson,Sylvia H, AU - Wolf,Bethany J, AU - Bingham,Kayla, AU - Scotland,Quiana S, AU - Fox,John M, AU - Woltz,Erick M, AU - Hebbar,Latha, PY - 2017/6/18/pubmed PY - 2019/1/1/medline PY - 2017/6/17/entrez SP - 545 EP - 551 JF - Anesthesia and analgesia JO - Anesth Analg VL - 126 IS - 2 N2 - BACKGROUND: Lumbar epidurals (LEs) provide excellent analgesia. Combined spinal epidural and dural puncture epidural (DPE) are 2 techniques to expedite neuraxial analgesia onset. In DPE, dura is punctured but medication is not administered in the cerebrospinal fluid. Expedited analgesia onset has been demonstrated with DPE, using 0.25% bupivacaine; however, this concentration may impede an unassisted vaginal birth and is not currently used for induction and maintenance of labor analgesia. The primary goal of this study was to compare the percentage of patients who achieved adequate labor analgesia following DPE or LE with an epidural bolus of 0.125% bupivacaine. Adequate labor analgesia was defined as Visual Analog Scale (VAS) measurement ≤ 10 mm on a 100-mm scale during active contractions, measured 10 minutes after epidural bolus initiation. METHODS: Laboring patients were randomly assigned to receive LE or DPE. Immediately before epidural placement, subjects marked a VAS score during an active contraction and parturients with VAS < 50 mm were excluded. The epidural space was identified by a loss of resistance technique to saline (17G Tuohy needle [Arrow International, Inc, Redding, PA]). In the DPE group, dura was punctured with a 26G Whitacre needle (Arrow International, Inc). In all participants, a 19G epidural catheter (Arrow International, Inc) was inserted. An epidural bolus was then administered over 3 minutes (12 mL, 0.125% bupivacaine, 50 μg fentanyl) followed by infusion (0.1% bupivacaine, 2 μg/mL fentanyl). After initiation of epidural bolus (time zero), VAS measurements were collected at 2-minute intervals for up to 20 minutes. Median time to achieve adequate analgesia by treatment group was assessed by Kaplan-Meier analysis. Time to achieving adequate analgesia was evaluated using a Cox regression model. All analyses were conducted in SAS version 9.4. (SAS Institute, Cary, NC) RESULTS:: Data were analyzed from 80 participants (40 per group). Adequate analgesia at 10 minutes did not differ by neuraxial technique (DPE = 55.3% vs LE = 44.7%; P= .256). However, parturients receiving DPE had shorter median times to adequate analgesia (median [95% confidence interval], 8 minutes [6-10] vs 10 minutes [8-14]) and a 67% increase in the relative risk of achieving adequate analgesia compared to LE (relative risk = 1.67; 95% confidence interval, 1.02-2.64; P= .042). CONCLUSIONS: Although the percentage of parturients achieving adequate labor analgesia at 10 minutes after epidural bolus did not differ by technique, DPE was associated with faster time to VAS ≤ 10 mm compared with LE. SN - 1526-7598 UR - https://www.unboundmedicine.com/medline/citation/28622178/Labor_Analgesia_Onset_With_Dural_Puncture_Epidural_Versus_Traditional_Epidural_Using_a_26_Gauge_Whitacre_Needle_and_0_125_Bupivacaine_Bolus:_A_Randomized_Clinical_Trial_ DB - PRIME DP - Unbound Medicine ER -