A systematic review and meta-analysis of single-incision mini-slings (MiniArc) versus transobturator mid-urethral slings in surgical management of female stress urinary incontinence.
Medicine (Baltimore). 2018 Apr; 97(14):e0283.M

Abstract

BACKGROUND

To assess the current evidence of effectiveness and safety of single-incision mini-slings (MiniArc) versus transobturator midurethral slings in the management of female stress urinary incontinence (SUI).

METHODS

A systematic search was performed from the electronic databases including PubMed, EMBASE, and Cochrane Library by November 2017. Using RevMan5.3 statistical software, the primary outcomes including subject and objective cure rates at 6 to 24 months follow-up were evaluated. Meanwhile, analysis was also performed for comparing the secondary outcomes such as peri- and postoperative complications, operative data, and quality of life.

RESULTS

Six randomized controlled trials (RCTs) and 6 retrospective cohort studies involving 1794 patients with SUI were analyzed based on the inclusion criteria. On the basis of our analysis, MiniArc was proven to have a noninferior clinical efficacy compared with transobturator midurethral slings with respect to the objective cure rate (risk ratio [RR] = 0.98, 95% confidence interval [CI] 0.94-1.03, P = .43) and subjective cure rate (RR = 0.97, 95% CI 0.91-1. 04, P = .38). In addition, pooled analysis showed that MiniArc had significantly lower postoperative pain scores (mean difference [MD] = -1.70, 95% CI -3.17 to -0.23, P = .02) and less postoperative groin pain (RR = 0.42, 95% CI 0.18-0.98, P = .04). Moreover, the MiniArc group also had a significantly shorter operation time (MD = -6.12, 95% CI -8.61 to -3.64, P < .001), less blood loss (MD = -16.67, 95% CI -26.29 to -7.05, P < .001), shorter in-patient stay (MD = 1.30, 95% CI -1.74 to -0.86, P < .001), and less urinary retention risk (RR = 1.15, 95% CI 0.46-2.87, P = .77). However, overall evidence was insufficient to suggest a statistically significant difference in the adverse event profile for MiniArc compared with transobturator slings.

CONCLUSIONS

This meta-analysis indicates that MiniArc is an effective method treating SUI. When compared with transobturator slings, it not only has a similar high cure rates, but also is associated with shorter operation time, less blood loss, more favorable recovery time, lower postoperative pain scores, less postoperative groin pain, less urinary retention, and absence of a visible wound. However, the findings of this study should be further confirmed by well-designed prospective RCTs with a larger patient series.

Authors+Show Affiliations

Peking University China-Japan Friendship School of Clinical Medicine Department of Urology, China-Japan Friendship Hospital, Chaoyang Peking University Fifth School of Clinical Medicine Department of Urology, Beijing Hospital, Dongcheng, Beijing, China.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article
Meta-Analysis
Review
Systematic Review

Language

eng

PubMed ID

29620645

Citation

Jiao, Binbin, et al. "A Systematic Review and Meta-analysis of Single-incision Mini-slings (MiniArc) Versus Transobturator Mid-urethral Slings in Surgical Management of Female Stress Urinary Incontinence." Medicine, vol. 97, no. 14, 2018, pp. e0283.
Jiao B, Lai S, Xu X, et al. A systematic review and meta-analysis of single-incision mini-slings (MiniArc) versus transobturator mid-urethral slings in surgical management of female stress urinary incontinence. Medicine (Baltimore). 2018;97(14):e0283.
Jiao, B., Lai, S., Xu, X., Zhang, M., Diao, T., & Zhang, G. (2018). A systematic review and meta-analysis of single-incision mini-slings (MiniArc) versus transobturator mid-urethral slings in surgical management of female stress urinary incontinence. Medicine, 97(14), e0283. https://doi.org/10.1097/MD.0000000000010283
Jiao B, et al. A Systematic Review and Meta-analysis of Single-incision Mini-slings (MiniArc) Versus Transobturator Mid-urethral Slings in Surgical Management of Female Stress Urinary Incontinence. Medicine (Baltimore). 2018;97(14):e0283. PubMed PMID: 29620645.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - A systematic review and meta-analysis of single-incision mini-slings (MiniArc) versus transobturator mid-urethral slings in surgical management of female stress urinary incontinence. AU - Jiao,Binbin, AU - Lai,Shicong, AU - Xu,Xin, AU - Zhang,Meng, AU - Diao,Tongxiang, AU - Zhang,Guan, PY - 2018/4/6/entrez PY - 2018/4/6/pubmed PY - 2018/4/17/medline SP - e0283 EP - e0283 JF - Medicine JO - Medicine (Baltimore) VL - 97 IS - 14 N2 - BACKGROUND: To assess the current evidence of effectiveness and safety of single-incision mini-slings (MiniArc) versus transobturator midurethral slings in the management of female stress urinary incontinence (SUI). METHODS: A systematic search was performed from the electronic databases including PubMed, EMBASE, and Cochrane Library by November 2017. Using RevMan5.3 statistical software, the primary outcomes including subject and objective cure rates at 6 to 24 months follow-up were evaluated. Meanwhile, analysis was also performed for comparing the secondary outcomes such as peri- and postoperative complications, operative data, and quality of life. RESULTS: Six randomized controlled trials (RCTs) and 6 retrospective cohort studies involving 1794 patients with SUI were analyzed based on the inclusion criteria. On the basis of our analysis, MiniArc was proven to have a noninferior clinical efficacy compared with transobturator midurethral slings with respect to the objective cure rate (risk ratio [RR] = 0.98, 95% confidence interval [CI] 0.94-1.03, P = .43) and subjective cure rate (RR = 0.97, 95% CI 0.91-1. 04, P = .38). In addition, pooled analysis showed that MiniArc had significantly lower postoperative pain scores (mean difference [MD] = -1.70, 95% CI -3.17 to -0.23, P = .02) and less postoperative groin pain (RR = 0.42, 95% CI 0.18-0.98, P = .04). Moreover, the MiniArc group also had a significantly shorter operation time (MD = -6.12, 95% CI -8.61 to -3.64, P < .001), less blood loss (MD = -16.67, 95% CI -26.29 to -7.05, P < .001), shorter in-patient stay (MD = 1.30, 95% CI -1.74 to -0.86, P < .001), and less urinary retention risk (RR = 1.15, 95% CI 0.46-2.87, P = .77). However, overall evidence was insufficient to suggest a statistically significant difference in the adverse event profile for MiniArc compared with transobturator slings. CONCLUSIONS: This meta-analysis indicates that MiniArc is an effective method treating SUI. When compared with transobturator slings, it not only has a similar high cure rates, but also is associated with shorter operation time, less blood loss, more favorable recovery time, lower postoperative pain scores, less postoperative groin pain, less urinary retention, and absence of a visible wound. However, the findings of this study should be further confirmed by well-designed prospective RCTs with a larger patient series. SN - 1536-5964 UR - https://www.unboundmedicine.com/medline/citation/29620645/A_systematic_review_and_meta_analysis_of_single_incision_mini_slings__MiniArc__versus_transobturator_mid_urethral_slings_in_surgical_management_of_female_stress_urinary_incontinence_ L2 - https://doi.org/10.1097/MD.0000000000010283 DB - PRIME DP - Unbound Medicine ER -