Tags

Type your tag names separated by a space and hit enter

Utility of a Rapid Lateral Flow Assay To Resolve Erroneous Identification of Burkholderia pseudomallei as Burkholderia thailandensis by Matrix-Assisted Laser Desorption Ionization-Time of Flight (MALDI-TOF) Mass Spectrometry.
J Clin Microbiol. 2018 12; 56(12)JC

Authors+Show Affiliations

Department of Microbiology and Infectious Diseases, SA Pathology, Adelaide, South Australia, Australia susan.harch@sa.gov.au.Menzies School of Health Research, Charles Darwin University, Darwin, Northern Territory, Australia.Department of Infectious Diseases, Royal Adelaide Hospital, Adelaide, South Australia, Australia.Menzies School of Health Research, Charles Darwin University, Darwin, Northern Territory, Australia.Department of Microbiology and Infectious Diseases, Royal Darwin Hospital, Darwin, Northern Territory, Australia.Department of Microbiology and Infectious Diseases, SA Pathology, Adelaide, South Australia, Australia.

Pub Type(s)

Case Reports
Letter

Language

eng

PubMed ID

30282790

Citation

Harch, Susan A J., et al. "Utility of a Rapid Lateral Flow Assay to Resolve Erroneous Identification of Burkholderia Pseudomallei as Burkholderia Thailandensis By Matrix-Assisted Laser Desorption Ionization-Time of Flight (MALDI-TOF) Mass Spectrometry." Journal of Clinical Microbiology, vol. 56, no. 12, 2018.
Harch SAJ, Currie BJ, Papanicolas L, et al. Utility of a Rapid Lateral Flow Assay To Resolve Erroneous Identification of Burkholderia pseudomallei as Burkholderia thailandensis by Matrix-Assisted Laser Desorption Ionization-Time of Flight (MALDI-TOF) Mass Spectrometry. J Clin Microbiol. 2018;56(12).
Harch, S. A. J., Currie, B. J., Papanicolas, L., Rigas, V., Baird, R., & Bastian, I. (2018). Utility of a Rapid Lateral Flow Assay To Resolve Erroneous Identification of Burkholderia pseudomallei as Burkholderia thailandensis by Matrix-Assisted Laser Desorption Ionization-Time of Flight (MALDI-TOF) Mass Spectrometry. Journal of Clinical Microbiology, 56(12). https://doi.org/10.1128/JCM.01437-18
Harch SAJ, et al. Utility of a Rapid Lateral Flow Assay to Resolve Erroneous Identification of Burkholderia Pseudomallei as Burkholderia Thailandensis By Matrix-Assisted Laser Desorption Ionization-Time of Flight (MALDI-TOF) Mass Spectrometry. J Clin Microbiol. 2018;56(12) PubMed PMID: 30282790.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Utility of a Rapid Lateral Flow Assay To Resolve Erroneous Identification of Burkholderia pseudomallei as Burkholderia thailandensis by Matrix-Assisted Laser Desorption Ionization-Time of Flight (MALDI-TOF) Mass Spectrometry. AU - Harch,Susan A J, AU - Currie,Bart J, AU - Papanicolas,Lito, AU - Rigas,Vanessa, AU - Baird,Rob, AU - Bastian,Ivan, Y1 - 2018/11/27/ PY - 2018/10/5/pubmed PY - 2019/9/7/medline PY - 2018/10/5/entrez KW - Burkholderia pseudomallei KW - MALDI-TOF mass spectrometry KW - lateral flow assays JF - Journal of clinical microbiology JO - J Clin Microbiol VL - 56 IS - 12 SN - 1098-660X UR - https://www.unboundmedicine.com/medline/citation/30282790/Utility_of_a_Rapid_Lateral_Flow_Assay_To_Resolve_Erroneous_Identification_of_Burkholderia_pseudomallei_as_Burkholderia_thailandensis_by_Matrix_Assisted_Laser_Desorption_Ionization_Time_of_Flight__MALDI_TOF__Mass_Spectrometry_ L2 - http://jcm.asm.org/cgi/pmidlookup?view=long&pmid=30282790 DB - PRIME DP - Unbound Medicine ER -