We present the case of a 30 years old woman who had an Interauterine Device placed in a fragile uterus (puerperal period) 5 years ago and presented with dull abdominal pain and disturbed bowel habits. Failure to pull out IUD strings on gynecological examination made us suspicious of translocated IUD and its ectopic placement in sigmoid colon was confirmed on colonoscopy and a CT abdomen with contrast. The transmigrated IUD was removed following laparotomy.

Authors+Show Affiliations

North Surgical Ward, Mayo Hospital, Lahore.North Surgical Ward, Mayo Hospital, Lahore.North Surgical Ward, Mayo Hospital, Lahore.Mayo Hospital, Lahore.

Pub Type(s)

Case Reports
Journal Article

Language

eng

PubMed ID

30410158

Citation

Kaleem, Ahmad, et al. "Transmigration of an Intrauterine Device Into Sigmoid Colon-surgical Management: a Case Report." JPMA. the Journal of the Pakistan Medical Association, vol. 68, no. 11, 2018, pp. 1716-1718.
Kaleem A, Zaman BS, Hassan A, et al. Transmigration of an intrauterine device into sigmoid colon-surgical management: A case report. J Pak Med Assoc. 2018;68(11):1716-1718.
Kaleem, A., Zaman, B. S., Hassan, A., & Nasir, M. (2018). Transmigration of an intrauterine device into sigmoid colon-surgical management: A case report. JPMA. the Journal of the Pakistan Medical Association, 68(11), pp. 1716-1718.
Kaleem A, et al. Transmigration of an Intrauterine Device Into Sigmoid Colon-surgical Management: a Case Report. J Pak Med Assoc. 2018;68(11):1716-1718. PubMed PMID: 30410158.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Transmigration of an intrauterine device into sigmoid colon-surgical management: A case report. AU - Kaleem,Ahmad, AU - Zaman,Balakh Sher, AU - Hassan,Azhar, AU - Nasir,Muneeba, PY - 2018/11/10/entrez PY - 2018/11/10/pubmed PY - 2019/10/1/medline KW - Intrauterine device, Sigmoid colon, Case report. SP - 1716 EP - 1718 JF - JPMA. The Journal of the Pakistan Medical Association JO - J Pak Med Assoc VL - 68 IS - 11 N2 - We present the case of a 30 years old woman who had an Interauterine Device placed in a fragile uterus (puerperal period) 5 years ago and presented with dull abdominal pain and disturbed bowel habits. Failure to pull out IUD strings on gynecological examination made us suspicious of translocated IUD and its ectopic placement in sigmoid colon was confirmed on colonoscopy and a CT abdomen with contrast. The transmigrated IUD was removed following laparotomy. SN - 0030-9982 UR - https://www.unboundmedicine.com/medline/citation/30410158/Transmigration_of_an_intrauterine_device_into_sigmoid_colon_surgical_management:_A_case_report_ L2 - http://jpma.org.pk/full_article-text.php?article_id=8945 DB - PRIME DP - Unbound Medicine ER -