Radiochemical purity of technetium-99m-nanocolloid rhenium sulphide is not influenced by heating.
Nucl Med Commun. 2019 Jun; 40(6):565-567.NM

Abstract

Despite a mistake during the preparation of technetium-99m (Tc)-nanocolloid rhenium sulphide (Nanocis) because of lack of heating, the apparent radiochemical purity (RCP) of this product was correct. The objectives of this study were to evaluate the impact of absence of heating on the RCP of Tc-nanocolloid rhenium sulphide and the effect of heating on particle size. Five Tc-Nanocis were prepared according to the manufacturer's instructions and five others were realized without any heating step. Quality controls were performed for each preparation. To evaluate the effect of heating on particle size, preparations were filtered through a 0.22 µm sterilizing membrane filter before and after 30 min of heating. The radioactivity was measured before and after the filtration. The results showed that absence of heating does not influence the apparent RCP of Tc-nanocolloid of rhenium sulphide. In terms of the particle size, 72% of particles had a diameter less than 0.22 µm before heating, as opposed to 21% after heating. To conclude, this study underlines a problem of quality control of the Tc-nanocolloid rhenium sulphide preparation, which cannot detect a lack of heating and can lead to the release of preparations that would not be suitable for scintigraphy.

Authors+Show Affiliations

Radiopharmacy Unit, Departement of Pharmacy, Groupement Hospitalier Est, Hospices Civils de Lyon, 59 boulevard Pinel, 69677 Bron Cedex.Radiopharmacy Unit, Departement of Pharmacy, Groupement Hospitalier Est, Hospices Civils de Lyon, 59 boulevard Pinel, 69677 Bron Cedex.Radiopharmacy Unit, Departement of Pharmacy, Groupement Hospitalier Est, Hospices Civils de Lyon, 59 boulevard Pinel, 69677 Bron Cedex.Radiopharmacy Unit, Departement of Pharmacy, Groupement Hospitalier Est, Hospices Civils de Lyon, 59 boulevard Pinel, 69677 Bron Cedex.Radiopharmacy Unit, Departement of Pharmacy, Groupement Hospitalier Est, Hospices Civils de Lyon, 59 boulevard Pinel, 69677 Bron Cedex.Radiopharmacy Unit, Departement of Pharmacy, Groupement Hospitalier Est, Hospices Civils de Lyon, 59 boulevard Pinel, 69677 Bron Cedex.Radiopharmacy Unit, Departement of Pharmacy, Groupement Hospitalier Est, Hospices Civils de Lyon, 59 boulevard Pinel, 69677 Bron Cedex. University of Lyon, University Claude Bernard Lyon 1, Lyon Neuroscience Research Center, CNRS UMR5292, INSERM U1028, Lyon, France.

Pub Type(s)

Journal Article

Language

eng

PubMed ID

30720668

Citation

Galland, Laura, et al. "Radiochemical Purity of Technetium-99m-nanocolloid Rhenium Sulphide Is Not Influenced By Heating." Nuclear Medicine Communications, vol. 40, no. 6, 2019, pp. 565-567.
Galland L, Bolot C, Rosinski S, et al. Radiochemical purity of technetium-99m-nanocolloid rhenium sulphide is not influenced by heating. Nucl Med Commun. 2019;40(6):565-567.
Galland, L., Bolot, C., Rosinski, S., Bruno, A., Forel, S., Bréant, V., & Levigoureux, E. (2019). Radiochemical purity of technetium-99m-nanocolloid rhenium sulphide is not influenced by heating. Nuclear Medicine Communications, 40(6), 565-567. https://doi.org/10.1097/MNM.0000000000000988
Galland L, et al. Radiochemical Purity of Technetium-99m-nanocolloid Rhenium Sulphide Is Not Influenced By Heating. Nucl Med Commun. 2019;40(6):565-567. PubMed PMID: 30720668.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Radiochemical purity of technetium-99m-nanocolloid rhenium sulphide is not influenced by heating. AU - Galland,Laura, AU - Bolot,Claire, AU - Rosinski,Sylvain, AU - Bruno,Aurélie, AU - Forel,Sandra, AU - Bréant,Valentine, AU - Levigoureux,Elise, PY - 2019/2/6/pubmed PY - 2019/6/21/medline PY - 2019/2/6/entrez SP - 565 EP - 567 JF - Nuclear medicine communications JO - Nucl Med Commun VL - 40 IS - 6 N2 - Despite a mistake during the preparation of technetium-99m (Tc)-nanocolloid rhenium sulphide (Nanocis) because of lack of heating, the apparent radiochemical purity (RCP) of this product was correct. The objectives of this study were to evaluate the impact of absence of heating on the RCP of Tc-nanocolloid rhenium sulphide and the effect of heating on particle size. Five Tc-Nanocis were prepared according to the manufacturer's instructions and five others were realized without any heating step. Quality controls were performed for each preparation. To evaluate the effect of heating on particle size, preparations were filtered through a 0.22 µm sterilizing membrane filter before and after 30 min of heating. The radioactivity was measured before and after the filtration. The results showed that absence of heating does not influence the apparent RCP of Tc-nanocolloid of rhenium sulphide. In terms of the particle size, 72% of particles had a diameter less than 0.22 µm before heating, as opposed to 21% after heating. To conclude, this study underlines a problem of quality control of the Tc-nanocolloid rhenium sulphide preparation, which cannot detect a lack of heating and can lead to the release of preparations that would not be suitable for scintigraphy. SN - 1473-5628 UR - https://www.unboundmedicine.com/medline/citation/30720668/Radiochemical_purity_of_technetium_99m_nanocolloid_rhenium_sulphide_is_not_influenced_by_heating_ DB - PRIME DP - Unbound Medicine ER -