Management of the missing intrauterine contraceptive device: report of a case.Am J Obstet Gynecol 1985; 153(2):228-9AJ
Abstract
A case of postpartum intrauterine contraceptive device insertion that resulted in a remote complication is described. At the postinsertion follow-up visit the intrauterine contraceptive device was missing and presumed expelled. Four years later it was recovered from a complex mass involving the bladder and the appendix. Management for the missing intrauterine contraceptive device is recommended.
Links
MeSH
Pub Type(s)
Case Reports
Journal Article
Language
eng
PubMed ID
3898848
Citation
Gorsline, J C., and N G. Osborne. "Management of the Missing Intrauterine Contraceptive Device: Report of a Case." American Journal of Obstetrics and Gynecology, vol. 153, no. 2, 1985, pp. 228-9.
Gorsline JC, Osborne NG. Management of the missing intrauterine contraceptive device: report of a case. Am J Obstet Gynecol. 1985;153(2):228-9.
Gorsline, J. C., & Osborne, N. G. (1985). Management of the missing intrauterine contraceptive device: report of a case. American Journal of Obstetrics and Gynecology, 153(2), pp. 228-9.
Gorsline JC, Osborne NG. Management of the Missing Intrauterine Contraceptive Device: Report of a Case. Am J Obstet Gynecol. 1985 Sep 15;153(2):228-9. PubMed PMID: 3898848.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR
T1 - Management of the missing intrauterine contraceptive device: report of a case.
AU - Gorsline,J C,
AU - Osborne,N G,
PY - 1985/9/15/pubmed
PY - 1985/9/15/medline
PY - 1985/9/15/entrez
KW - Biology
KW - Case Studies
KW - Contraception--complications
KW - Contraceptive Methods--complications
KW - Diseases
KW - Family Planning
KW - Genital Effects, Female
KW - Genitalia
KW - Genitalia, Female
KW - Iud, Copper Releasing
KW - Iud--complications
KW - Perforations
KW - Physiology
KW - Research Methodology
KW - Studies
KW - Urogenital Effects
KW - Urogenital System
KW - Uterine Effects
KW - Uterine Perforation
KW - Uterus
SP - 228
EP - 9
JF - American journal of obstetrics and gynecology
JO - Am. J. Obstet. Gynecol.
VL - 153
IS - 2
N2 - A case of postpartum intrauterine contraceptive device insertion that resulted in a remote complication is described. At the postinsertion follow-up visit the intrauterine contraceptive device was missing and presumed expelled. Four years later it was recovered from a complex mass involving the bladder and the appendix. Management for the missing intrauterine contraceptive device is recommended.