Abstract

For closed-loop glycemic control on IDDM, closed-loop sc insulin infusion algorithm has developed by analysing the pharmacokinetics of sc insulin absorption. With the algorithm, daily glycemic excursion in IDDMs was controlled to near-normal levels. These data suggested that the closed-loop sc insulin infusion algorithm might be feasible to regulate glycemia in diabetic patients for a long-term period by wearable artificial endocrine pancreas.

Authors+Show Affiliations

First Department of Medicine, Osaka University Medical School, Japan.No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Comparative Study
Journal Article

Language

eng

PubMed ID

3916624

Citation

Shichiri, M, et al. "Long-term Application of Wearable Artificial Endocrine Pancreas--closed-loop Intravenous Vs Subcutaneous Insulin Infusion." Life Support Systems : the Journal of the European Society for Artificial Organs, vol. 3 Suppl 1, 1985, pp. 583-7.
Shichiri M, Kawamori R, Goriya Y, et al. Long-term application of wearable artificial endocrine pancreas--closed-loop intravenous vs subcutaneous insulin infusion. Life Support Syst. 1985;3 Suppl 1:583-7.
Shichiri, M., Kawamori, R., Goriya, Y., Yamasaki, Y., Nomura, M., Asakawa, N., Kubota, M., & Kamada, T. (1985). Long-term application of wearable artificial endocrine pancreas--closed-loop intravenous vs subcutaneous insulin infusion. Life Support Systems : the Journal of the European Society for Artificial Organs, 3 Suppl 1, 583-7.
Shichiri M, et al. Long-term Application of Wearable Artificial Endocrine Pancreas--closed-loop Intravenous Vs Subcutaneous Insulin Infusion. Life Support Syst. 1985;3 Suppl 1:583-7. PubMed PMID: 3916624.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Long-term application of wearable artificial endocrine pancreas--closed-loop intravenous vs subcutaneous insulin infusion. AU - Shichiri,M, AU - Kawamori,R, AU - Goriya,Y, AU - Yamasaki,Y, AU - Nomura,M, AU - Asakawa,N, AU - Kubota,M, AU - Kamada,T, PY - 1985/1/1/pubmed PY - 1985/1/1/medline PY - 1985/1/1/entrez SP - 583 EP - 7 JF - Life support systems : the journal of the European Society for Artificial Organs JO - Life Support Syst VL - 3 Suppl 1 N2 - For closed-loop glycemic control on IDDM, closed-loop sc insulin infusion algorithm has developed by analysing the pharmacokinetics of sc insulin absorption. With the algorithm, daily glycemic excursion in IDDMs was controlled to near-normal levels. These data suggested that the closed-loop sc insulin infusion algorithm might be feasible to regulate glycemia in diabetic patients for a long-term period by wearable artificial endocrine pancreas. SN - 0261-989X UR - https://www.unboundmedicine.com/medline/citation/3916624/Long_term_application_of_wearable_artificial_endocrine_pancreas__closed_loop_intravenous_vs_subcutaneous_insulin_infusion_ L2 - https://www.lens.org/lens/search/patent/list?q=citation_id:3916624 DB - PRIME DP - Unbound Medicine ER -