Clinical application of pre-programmed insulin infusion: continuous subcutaneous insulin therapy with a portable infusion system.

Abstract

Strict control of blood glucose was achieved by continuous subcutaneous insulin infusion with a specially adapted Mill Hill Infuser for 3-4 days. This led to normalisation of some of the intermediary metabolites. In a few patients, subcutaneous infusions have been carried out for periods up to 3 months with home monitoring of blood glucose, without infection or lipodystrophy. Short-term improvement of metabolic control was associated with recovery of abnormal renal glomerular permeability to albumin.

Authors

No affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info availableNo affiliation info available

Pub Type(s)

Journal Article

Language

eng

PubMed ID

395081

Citation

Pickup, J C., et al. "Clinical Application of Pre-programmed Insulin Infusion: Continuous Subcutaneous Insulin Therapy With a Portable Infusion System." Hormone and Metabolic Research. Supplement Series, 1979, pp. 202-4.
Pickup JC, Viberti GC, Keen H, et al. Clinical application of pre-programmed insulin infusion: continuous subcutaneous insulin therapy with a portable infusion system. Horm Metab Res Suppl. 1979.
Pickup, J. C., Viberti, G. C., Keen, H., Parsons, J. A., & Alberti, K. G. (1979). Clinical application of pre-programmed insulin infusion: continuous subcutaneous insulin therapy with a portable infusion system. Hormone and Metabolic Research. Supplement Series, (8), 202-4.
Pickup JC, et al. Clinical Application of Pre-programmed Insulin Infusion: Continuous Subcutaneous Insulin Therapy With a Portable Infusion System. Horm Metab Res Suppl. 1979;(8)202-4. PubMed PMID: 395081.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR T1 - Clinical application of pre-programmed insulin infusion: continuous subcutaneous insulin therapy with a portable infusion system. AU - Pickup,J C, AU - Viberti,G C, AU - Keen,H, AU - Parsons,J A, AU - Alberti,K G, PY - 1979/1/1/pubmed PY - 1979/1/1/medline PY - 1979/1/1/entrez SP - 202 EP - 4 JF - Hormone and metabolic research. Supplement series JO - Horm Metab Res Suppl IS - 8 N2 - Strict control of blood glucose was achieved by continuous subcutaneous insulin infusion with a specially adapted Mill Hill Infuser for 3-4 days. This led to normalisation of some of the intermediary metabolites. In a few patients, subcutaneous infusions have been carried out for periods up to 3 months with home monitoring of blood glucose, without infection or lipodystrophy. Short-term improvement of metabolic control was associated with recovery of abnormal renal glomerular permeability to albumin. SN - 0170-5903 UR - https://www.unboundmedicine.com/medline/citation/395081/Clinical_application_of_pre_programmed_insulin_infusion:_continuous_subcutaneous_insulin_therapy_with_a_portable_infusion_system_ L2 - https://medlineplus.gov/diabetesmedicines.html DB - PRIME DP - Unbound Medicine ER -