Closed-loop system in evaluation of insulin infusion rates for an open-loop system.Horm Metab Res Suppl. 1979HM
Abstract
The daily insulin requirements as calculated with a closed-loop system (Biostator), were used for insulin infusion with a portable, miniaturized pump in 6 juvenile-onset, insulin-requiring diabetics. Three diabetics were given insulin in a manner like that of the Biostator, e.g., maximal insulin infusion about 1 hour after start of meals. The MBG was 8.7 +/- 3.9 (SD) mmol/l. Three other diabetics had insulin in a fixed profile with peaks beginning simultaneously with meals. MBG of these patients was 4.4 +/- 1.9 mmol/l. Knowing the daily insulin dosage as calculated from the Biostator, normal blood glucose levels can be achieved with a fixed profile of insulin given by a portable pump.
MeSH
Pub Type(s)
Comparative Study
Journal Article
Language
eng
PubMed ID
395082
Citation
Kølendorf, K, et al. "Closed-loop System in Evaluation of Insulin Infusion Rates for an Open-loop System." Hormone and Metabolic Research. Supplement Series, 1979, pp. 205-6.
Kølendorf K, Christiansen JS, Svendsen PA, et al. Closed-loop system in evaluation of insulin infusion rates for an open-loop system. Horm Metab Res Suppl. 1979.
Kølendorf, K., Christiansen, J. S., Svendsen, P. A., & Bojsen, J. (1979). Closed-loop system in evaluation of insulin infusion rates for an open-loop system. Hormone and Metabolic Research. Supplement Series, (8), 205-6.
Kølendorf K, et al. Closed-loop System in Evaluation of Insulin Infusion Rates for an Open-loop System. Horm Metab Res Suppl. 1979;(8)205-6. PubMed PMID: 395082.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR
T1 - Closed-loop system in evaluation of insulin infusion rates for an open-loop system.
AU - Kølendorf,K,
AU - Christiansen,J S,
AU - Svendsen,P A,
AU - Bojsen,J,
PY - 1979/1/1/pubmed
PY - 1979/1/1/medline
PY - 1979/1/1/entrez
SP - 205
EP - 6
JF - Hormone and metabolic research. Supplement series
JO - Horm Metab Res Suppl
IS - 8
N2 - The daily insulin requirements as calculated with a closed-loop system (Biostator), were used for insulin infusion with a portable, miniaturized pump in 6 juvenile-onset, insulin-requiring diabetics. Three diabetics were given insulin in a manner like that of the Biostator, e.g., maximal insulin infusion about 1 hour after start of meals. The MBG was 8.7 +/- 3.9 (SD) mmol/l. Three other diabetics had insulin in a fixed profile with peaks beginning simultaneously with meals. MBG of these patients was 4.4 +/- 1.9 mmol/l. Knowing the daily insulin dosage as calculated from the Biostator, normal blood glucose levels can be achieved with a fixed profile of insulin given by a portable pump.
SN - 0170-5903
UR - https://www.unboundmedicine.com/medline/citation/395082/Closed_loop_system_in_evaluation_of_insulin_infusion_rates_for_an_open_loop_system_
DB - PRIME
DP - Unbound Medicine
ER -