A portable, Preprogrammable insulin infusion system with 16 rates.Horm Metab Res Suppl. 1979HM
Abstract
An external, portable, programmable pump has been developed for long-term therapeutic i.v. insusion of drugs. The impulse-controlled system consists of a 250 g CMOS-electronic unit and an electromechanical infusor (200 g) containing a 10 ml disposable syringe. The infusion pattern during the 24-h cycle is manually programmed in 16 steps from 24 to 384 microliter per 0.5 h. The coefficient of variation of the infusate is less than 2% per 0.5 h. An alarm circuit monitors the pump speed and the reservoir volume. The infusion system can operate continuously for 7 days with a 1 Ah, 5.4 volt battery.
MeSH
Pub Type(s)
Journal Article
Language
eng
PubMed ID
395092
Citation
Kølendorf, K, and J Bojsen. "A Portable, Preprogrammable Insulin Infusion System With 16 Rates." Hormone and Metabolic Research. Supplement Series, 1979, pp. 65-6.
Kølendorf K, Bojsen J. A portable, Preprogrammable insulin infusion system with 16 rates. Horm Metab Res Suppl. 1979.
Kølendorf, K., & Bojsen, J. (1979). A portable, Preprogrammable insulin infusion system with 16 rates. Hormone and Metabolic Research. Supplement Series, (8), 65-6.
Kølendorf K, Bojsen J. A Portable, Preprogrammable Insulin Infusion System With 16 Rates. Horm Metab Res Suppl. 1979;(8)65-6. PubMed PMID: 395092.
* Article titles in AMA citation format should be in sentence-case
TY - JOUR
T1 - A portable, Preprogrammable insulin infusion system with 16 rates.
AU - Kølendorf,K,
AU - Bojsen,J,
PY - 1979/1/1/pubmed
PY - 1979/1/1/medline
PY - 1979/1/1/entrez
SP - 65
EP - 6
JF - Hormone and metabolic research. Supplement series
JO - Horm Metab Res Suppl
IS - 8
N2 - An external, portable, programmable pump has been developed for long-term therapeutic i.v. insusion of drugs. The impulse-controlled system consists of a 250 g CMOS-electronic unit and an electromechanical infusor (200 g) containing a 10 ml disposable syringe. The infusion pattern during the 24-h cycle is manually programmed in 16 steps from 24 to 384 microliter per 0.5 h. The coefficient of variation of the infusate is less than 2% per 0.5 h. An alarm circuit monitors the pump speed and the reservoir volume. The infusion system can operate continuously for 7 days with a 1 Ah, 5.4 volt battery.
SN - 0170-5903
UR - https://www.unboundmedicine.com/medline/citation/395092/A_portable_Preprogrammable_insulin_infusion_system_with_16_rates_
DB - PRIME
DP - Unbound Medicine
ER -